Back to Authors

Burkhoff, Daniel

https://orcid.org/0000-0003-3995-2466

Mayo Clinic

Cardiovascular Research Foundation

Citations 24

Right Ventricular Pressure–Volume Analysis Before and After Transcatheter Leaflet Approximation for Severe Mitral Regurgitation
Sarraf, Mohammad , Brener, Michael I. , Burkhoff, Daniel

JAMA Cardiology | February 8, 2021 | Volume: 6 | Issue: 2 | Pages: e207209

10.1001/jamacardio.2020.7209 Get It

Impact of Interatrial Shunts on Invasive Hemodynamics and Exercise Tolerance in Patients With Heart Failure
Griffin, Jan M. , Borlaug, Barry A. , Komtebedde, Jan , Litwin, Sheldon E. , Shah, Sanjiv J. , Kaye, David M. , Hoendermis, Elke S., Gustafsson, Finn , Wolsk, Emil , Uriel, Nir , Borlaug, Barry A , Kaye, David M , Shah, Sanjiv J , Gustafsson, Finn , Hasenfuß, Gerd , Burkhoff, Daniel

Journal of the American Heart Association | August 15, 2020 | Volume: 9 | Issue: 17 | Pages: No page available

10.1161/jaha.120.016760 Get It

Approximately 50% of patients with heart failure have preserved ejection fraction. Although a wide variety of conditions cause or contribute to heart failure with preserved ejection fraction, elevated left ventricular filling pressures, particularly during exercise, are common to all causes. Acute elevation in left‐sided filling pressures promotes lung congestion and symptoms of dyspnea, while chronic elevations often lead to pulmonary vascular remodeling, right heart failure, and increased risk of mortality. Pharmacologic therapies, including neurohormonal modulation and drugs that modify the nitric oxide/cyclic GMP‐protein kinase G pathway have thus far been limited in reducing symptoms or improving outcomes in patients with heart failure with preserved ejection fraction. Hence, alternative means of reducing the detrimental rise in left‐sided heart pressures are being explored. One proposed method of achieving this is to create an interatrial shunt, thus unloading the left heart at rest and during exercise. Currently available studies have shown 3‐ to 5‐mm Hg decreases of pulmonary capillary wedge pressure during exercise despite increased workload. The mechanisms underlying the hemodynamic changes are just starting to be understood. In this review we summarize results of recent studies aimed at elucidating the potential mechanisms of improved hemodynamics during exercise tolerance following interatrial shunt implantation and the current interatrial shunt devices under investigation.
Impact of Baseline Hemodynamics on the Effects of a Transcatheter Interatrial Shunt Device in Heart Failure With Preserved Ejection Fraction
Wessler, Jeffrey D. , Kaye, David M. , Gustafsson, Finn , Petrie, Mark C. , Hasenfuβ, Gerd, Borlaug, Barry A. , Komtebedde, Jan , Feldman, Ted , Shah, Sanjiv J. , Advisors, on behalf of the REDUCE-LAP-HF Trial Investigators and, Borlaug, Barry A , Kaye, David M , Petrie, Mark C , Shah, Sanjiv J , Lam, Carolyn S.P. , Burkhoff, Daniel , Advisors, on behalf of the REDUCE-LAP-HF Trial Investigators and, Gustafsson, Finn

Circulation: Heart Failure | September 14, 2018 | Volume: 11 | Issue: 8 | Pages: No page available

10.1161/circheartfailure.117.004540 Get It

Background Interatrial shunt device (IASD) effects have been described in patients with heart failure and ejection fractions (EFs) ≥40%. However, baseline characteristics that correlate with greatest hemodynamic effects are unknown. On the basis of fundamental principles, we hypothesized that larger pressure gradients between left and right atria would yield greater shunt flow and greater hemodynamic effects. Methods and Results REDUCE LAP-HF (Reduce Elevated Left Atrial Pressure in Patients With Heart Failure) was a multicenter study that investigated IASD safety and performance. Sixty-four patients with EF ≥40% underwent device implantation followed by hemodynamic assessments at rest and exercise, including pulmonary capillary wedge pressure (PCWP, surrogate for left atrial pressure) and central venous pressure (CVP). At 6 months, IASD resulted in an average pulmonary-to-systemic blood flow ratio of 1.27 and increased exercise tolerance. The PCWP-CVP gradient (ie, the driving pressure for shunt flow) decreased at peak exercise from 16.8±6.9 to 11.4±5.5 mm Hg, because of increased CVP (17.5±5.4 to 20.3±7.9 mm Hg; P =0.04) and decreased PCWP (34.1±7.6 to 31.6±8.0 mm Hg; P =0.025). Baseline PCWP-CVP gradient during exercise correlated with changes of both PCWP-CVP and PCWP: Δ(PCWP-CVP)=10.0−0.89·(PCWP-CVP) baseline ( r 2 =0.56) and ΔPCWP=7.54−0.60·(PCWP-CVP) baseline ( P =0.001). Hemodynamics of patients with EF ≥50% and those with EF <50% responded similarly to IASD. Conclusions In heart failure patients with EF ≥40%, IASD significantly reduced PCWP and PCWP-CVP at peak exercise. Patients with higher baseline PCWP-CVP gradient had greater reductions in both parameters at follow-up. Results were sustained through 12 months and were independent of whether EF was ≥50% or between 40% and 49%. Additional studies will help further define the baseline hemodynamic predictors of exercise, hemodynamic, and clinical efficacy of the IASD. Clinical Trial Registration URL: https://www.clinicaltrials.gov . Unique identifier: NCT01913613.
Resting and Exercise Haemodynamics in Relation to Six-Minute Walk Test in Patients with Heart Failure and Preserved Ejection Fraction
Wolsk, Emil , Kaye, David M. , Borlaug, Barry A. , Kitzman, Dalane W. , Komtebedde, Jan , Ponikowski, Piotr , Shah, Sanjiv J. , Gustafsson, Finn , Borlaug, Barry A , Kaye, David M , Shah, Sanjiv J , Burkhoff, Daniel , Lam, Carolyn S.P. , Ponikowski, Piotr , Gustafsson, Finn

European Journal of Heart Failure | September 26, 2017 | Volume: 20 | Issue: 4 | Pages: 715-722

10.1002/ejhf.976 Get It

Abstract Aims Patients with heart failure and preserved ejection fraction (HFpEF) are characterized by functional impairment and an abnormal haemodynamic response to exercise. The six-minute walk test (6MWT) serves as a standardized test for functional capacity quantification in heart failure patients, and is associated with cardiovascular outcomes. However, as the association between 6MWT and haemodynamic parameters during rest and exercise in HFpEF patients is unknown, we sought to elucidate this relationship. Methods and results Overall, 64 patients enrolled in the REDUCE LAP-HF trial completed a 6MWT at baseline. Univariate and multivariable linear regression models were used to assess the associations between 6MWT and measured or derived haemodynamic variables at baseline, during light/moderate exercise (20 W), and at peak supine exercise. The average 6MWT distance was 318 ± 106 m. At rest, in a multivariable model, only pulmonary capillary wedge pressure (PCWP) was significantly associated with 6MWT [coefficient: –5.4, 95% confidence interval (CI) –10.4, –0.5, P = 0.033]. During light/moderate exercise, mean pulmonary artery pressure was associated with 6MWT in a multivariable model (coefficient: –3.5, 95% CI –6.8, –0.3, P = 0.033). During peak exercise, central venous pressure, cardiac index (CI), and PCWP/CI correlated with 6MWT; however, workload corrected PCWP was the only variable independently associated with 6MWT (coefficient: –0.8, 95% CI –1.3, –0.4, P &lt; 0.001). The variance in 6MWT was modestly explained by measured or derived haemodynamic variables at rest or at any stage of exercise (r2 = 7–17%). Conclusion Workload corrected PCWP correlated best with 6MWT performance in HFpEF patients. Baseline haemodynamic variables were modestly correlated with 6MWT, suggesting that 6MWT performance in HFpEF patients may be significantly influenced by extra-cardiac factors.