Back to Authors

Wolsk, Emil

https://orcid.org/0000-0002-6064-062X

Mayo Clinic

Rigshospitalet

Citations 5

Pressure–flow responses to exercise in aortic stenosis, mitral regurgitation and diastolic dysfunction
Andersen, Mads J. , Wolsk, Emil , Bakkestrøm, Rine , Christensen, Nicolaj Lyhne , Carter‐Storch, Rasmus , Omar, Massar , Frederiksen, Peter , Borlaug, Barry A. , Gustafsson, Finn , Hassager, Christian , Borlaug, Barry A , Hassager, Christian , Frederiksen, Peter H , Omar, Massar , Andersen, Mads Jønsson , Carter-Storch, Rasmus , Gustafsson, Finn , Dahl, Jordi S. , Møller, Jacob Eifer

Heart | August 29, 2022 | Volume: 108 | Issue: 23 | Pages: 1895-1903

10.1136/heartjnl-2022-321204 Get It

Background Haemodynamic exercise testing is important for evaluating patients with dyspnoea on exertion and preserved ejection fraction. Despite very different pathologies, patients with pressure (aortic stenosis (AS)) and volume (mitral regurgitation (MR)) overload and diastolic dysfunction after recent acute myocardial infarction (AMI) reach similar filling pressure levels with exercise. The pressure–flow relationships (the association between change in cardiac output (∆CO) and change in pulmonary arterial wedge pressure (∆PAWP) may provide insight into haemodynamic adaptation to exercise in these groups. Methods and results One hundred sixty-eight subjects aged >50 years with a left ventricular ejection fraction of ≥50% underwent invasive exercise testing. They were enrolled in four different studies: AS (40 patients), AMI (52 patients), MR (43 patients) and 33 healthy subjects. Haemodynamic data were measured at rest, at 25 W, 75 W and at peak exercise. In all groups, PAWP increased with exercise. The greatest increase was observed in patients with AMI (from 12.7±3.9 mm Hg to 33.1±8.2 mm Hg, p<0.0001) and patients with AS (from 11.8±3.9 mm Hg to 31.4±6.1 mm Hg, p<0.0001), and the smallest was observed in healthy subjects (from 8.3±2.4 mm Hg to 21.1±7.5 mm Hg, p<0.0001). In all groups, the relative pressure increase was greatest at the beginning of the exercise. CO increased most in healthy patients (from 5.3±1.1 to 16.0±3.0 L/min, p<0.0001) and least in patients with AS (from 5.3±1.2 L/min to 12.4±2.6 L/min, p<0.0001). The pressure–flow relationships (∆PAWP/∆CO) and differed among groups (p = 0.02). In all groups, the pressure–flow relationship was steepest in the initial phase of the exercise test. The AMI and AS groups (2.3±1.2 mm Hg/L/min and 3.0±1.3 mm Hg/L/min, AMI and AS, respectively) had the largest overall pressure–flow relationship; the healthy group had the smallest initially and at peak exercise (1.3±1.1 mm Hg/L/min) followed by MR group (1.9±1.4 mm Hg/L/min). Conclusion The pressure–flow relationship was steepest in the initial phase of the exercise test in all groups. The pressure–flow relationship differs between groups. Trial registration numbers NCT01974557 , NCT01046838 , NCT02961647 and NCT02395107 .
Resting and Exercise Haemodynamic Characteristics of Patients with Advanced Heart Failure and Preserved Ejection Fraction
Deis, Tania , Wolsk, Emil , Mujkanovic, Jasmin , Komtebedde, Jan , Heyden, Jan Van der , Petrie, Mark C. , Kahwash, Rami , Hoendermis, Elke S., Hummel, Scott L. , Gustafsson, Finn , Hummel, Scott L , Petrie, Mark C , Gustafsson, Finn , Burkhoff, Daniel , Kaye, David M. , Hasenfuß, Gerd , Hayward, Chris , Shah, Sanjiv J , Borlaug, Barry A. , Litwin, Sheldon E.

ESC Heart Failure | December 8, 2021 | Volume: 9 | Issue: 1 | Pages: 186-195

10.1002/ehf2.13697 Get It

Abstract Aims This study aimed to describe haemodynamic features of patients with advanced heart failure with preserved ejection fraction (HFpEF) as defined by the Heart Failure Association (HFA) of the European Society of Cardiology (ESC). Methods and results We used pooled data from two dedicated HFpEF studies with invasive exercise haemodynamic protocols, the REDUCE LAP-HF (Reduce Elevated Left Atrial Pressure in Patients with Heart Failure) trial and the REDUCE LAP-HF I trial, and categorized patients according to advanced heart failure (AdHF) criteria. The well-characterized HFpEF patients were considered advanced if they had persistent New York Heart Association classification of III–IV and heart failure (HF) hospitalization &lt; 12 months and a 6 min walk test distance &lt; 300 m. Twenty-four (22%) out of 108 patients met the AdHF criteria. On evaluation, clinical characteristics and resting haemodynamics were not different in the two groups. Patients with AdHF had lower work capacity compared with non-advanced patients (35 ± 16 vs. 45 ± 18 W, P = 0.021). Workload-corrected pulmonary capillary wedge pressure normalized to body weight (PCWL) was higher in AdHF patients compared with non-advanced (112 ± 55 vs. 86 ± 49 mmHg/W/kg, P = 0.04). Further, AdHF patients had a smaller increase in cardiac index during exercise (1.1 ± 0.7 vs. 1.6 ± 0.9 L/min/m2, P = 0.028). Conclusions A significantly higher PCWL and lower cardiac index reserve during exercise were observed in AdHF patients compared with non-advanced. These differences were not apparent at rest. Therapies targeting the haemodynamic compromise associated with advanced HFpEF are needed.
Determinants and consequences of heart rate and stroke volume response to exercise in patients with heart failure and preserved ejection fraction
Wolsk, Emil , Komtebedde, Jan , Kitzman, Dalane W. , Cleland, John G.F. , Hassager, Christian , Gustafsson, Finn , Hassager, Christian , Gustafsson, Finn , Kaye, David M. , Shah, Sanjiv J , Borlaug, Barry A. , Burkhoff, Daniel , Hasenfuß, Gerd , Møller, Jacob Eifer , Cleland, John G F

European Journal of Heart Failure | March 9, 2021 | Volume: 23 | Issue: 5 | Pages: 754-764

10.1002/ejhf.2146 Get It

Abstract Aims A hallmark of heart failure with preserved ejection fraction (HFpEF) is impaired exercise capacity of varying severity. The main determinant of exercise capacity is cardiac output (CO), however little information is available about the relation between the constituents of CO – heart rate and stroke volume – and exercise capacity in HFpEF. We sought to determine if a heterogeneity in heart rate and stroke volume response to exercise exists in patients with HFpEF and describe possible clinical phenotypes associated with differences in these responses. Methods and results Data from two prospective trials of HFpEF ( n = 108) and a study of healthy participants ( n = 42) with invasive haemodynamic measurements during exercise were utilized. Differences in central haemodynamic responses were analysed with regression models. Chronotropic incompetence was present in 39–56% of patients with HFpEF and 3–56% of healthy participants depending on the definition used, but some ( n = 47, 44%) had an increase in heart rate similar to that of healthy controls. Patients with HFpEF had a smaller increase in their stroke volume index (SVI) (HFpEF: +4 ± 10 mL/m 2 , healthy participants: +24 ± 12 mL/m 2 , P < 0.0001), indeed, SVI fell in 28% of patients at peak exercise. Higher body mass index and lower SVI at rest were associated with smaller increases in heart rate during exercise, whereas higher resting heart rate, and angiotensin‐converting enzyme inhibitor/angiotensin II receptor blocker use were associated with a greater increase in SVI in patients with HFpEF. Conclusion The haemodynamic response to exercise was very heterogeneous among patients with HFpEF, with chronotropic incompetence observed in up to 56%, and 28% had impaired increase in SVI. This suggests that haemodynamic exercise testing may be useful to identify which HFpEF patients may benefit from interventions targeting stroke volume and chronotropic response.
Impact of Interatrial Shunts on Invasive Hemodynamics and Exercise Tolerance in Patients With Heart Failure
Griffin, Jan M. , Borlaug, Barry A. , Komtebedde, Jan , Litwin, Sheldon E. , Shah, Sanjiv J. , Kaye, David M. , Hoendermis, Elke S., Gustafsson, Finn , Wolsk, Emil , Uriel, Nir , Borlaug, Barry A , Kaye, David M , Shah, Sanjiv J , Gustafsson, Finn , Hasenfuß, Gerd , Burkhoff, Daniel

Journal of the American Heart Association | August 15, 2020 | Volume: 9 | Issue: 17 | Pages: No page available

10.1161/jaha.120.016760 Get It

Approximately 50% of patients with heart failure have preserved ejection fraction. Although a wide variety of conditions cause or contribute to heart failure with preserved ejection fraction, elevated left ventricular filling pressures, particularly during exercise, are common to all causes. Acute elevation in left‐sided filling pressures promotes lung congestion and symptoms of dyspnea, while chronic elevations often lead to pulmonary vascular remodeling, right heart failure, and increased risk of mortality. Pharmacologic therapies, including neurohormonal modulation and drugs that modify the nitric oxide/cyclic GMP‐protein kinase G pathway have thus far been limited in reducing symptoms or improving outcomes in patients with heart failure with preserved ejection fraction. Hence, alternative means of reducing the detrimental rise in left‐sided heart pressures are being explored. One proposed method of achieving this is to create an interatrial shunt, thus unloading the left heart at rest and during exercise. Currently available studies have shown 3‐ to 5‐mm Hg decreases of pulmonary capillary wedge pressure during exercise despite increased workload. The mechanisms underlying the hemodynamic changes are just starting to be understood. In this review we summarize results of recent studies aimed at elucidating the potential mechanisms of improved hemodynamics during exercise tolerance following interatrial shunt implantation and the current interatrial shunt devices under investigation.
Resting and Exercise Haemodynamics in Relation to Six-Minute Walk Test in Patients with Heart Failure and Preserved Ejection Fraction
Wolsk, Emil , Kaye, David M. , Borlaug, Barry A. , Kitzman, Dalane W. , Komtebedde, Jan , Ponikowski, Piotr , Shah, Sanjiv J. , Gustafsson, Finn , Borlaug, Barry A , Kaye, David M , Shah, Sanjiv J , Burkhoff, Daniel , Lam, Carolyn S.P. , Ponikowski, Piotr , Gustafsson, Finn

European Journal of Heart Failure | September 26, 2017 | Volume: 20 | Issue: 4 | Pages: 715-722

10.1002/ejhf.976 Get It

Abstract Aims Patients with heart failure and preserved ejection fraction (HFpEF) are characterized by functional impairment and an abnormal haemodynamic response to exercise. The six-minute walk test (6MWT) serves as a standardized test for functional capacity quantification in heart failure patients, and is associated with cardiovascular outcomes. However, as the association between 6MWT and haemodynamic parameters during rest and exercise in HFpEF patients is unknown, we sought to elucidate this relationship. Methods and results Overall, 64 patients enrolled in the REDUCE LAP-HF trial completed a 6MWT at baseline. Univariate and multivariable linear regression models were used to assess the associations between 6MWT and measured or derived haemodynamic variables at baseline, during light/moderate exercise (20 W), and at peak supine exercise. The average 6MWT distance was 318 ± 106 m. At rest, in a multivariable model, only pulmonary capillary wedge pressure (PCWP) was significantly associated with 6MWT [coefficient: –5.4, 95% confidence interval (CI) –10.4, –0.5, P = 0.033]. During light/moderate exercise, mean pulmonary artery pressure was associated with 6MWT in a multivariable model (coefficient: –3.5, 95% CI –6.8, –0.3, P = 0.033). During peak exercise, central venous pressure, cardiac index (CI), and PCWP/CI correlated with 6MWT; however, workload corrected PCWP was the only variable independently associated with 6MWT (coefficient: –0.8, 95% CI –1.3, –0.4, P &lt; 0.001). The variance in 6MWT was modestly explained by measured or derived haemodynamic variables at rest or at any stage of exercise (r2 = 7–17%). Conclusion Workload corrected PCWP correlated best with 6MWT performance in HFpEF patients. Baseline haemodynamic variables were modestly correlated with 6MWT, suggesting that 6MWT performance in HFpEF patients may be significantly influenced by extra-cardiac factors.