AbstractBackgroundPeripheral nerve damage resulting in pain, loss of sensation, or motor function may necessitate a reconstruction with a bridging material. The RANGER® Registry was designed to evaluate outcomes following nerve repair with processed nerve allograft (Avance® Nerve Graft; Axogen; Alachua, FL). Here we report on the results from the largest peripheral nerve registry to‐date.MethodsThis multicenter IRB‐approved registry study collected data from patients repaired with processed nerve allograft (PNA). Sites followed their own standard of care for patient treatment and follow‐up. Data were assessed for meaningful recovery, defined as ≥S3/M3 to remain consistent with previously published results, and comparisons were made to reference literature.ResultsThe study included 385 subjects and 624 nerve repairs. Overall, 82% meaningful recovery (MR) was achieved across sensory, mixed, and motor nerve repairs up to gaps of 70 mm. No related adverse events were reported. There were no significant differences in MR across the nerve type, age, time‐to‐repair, and smoking status subgroups in the upper extremity (p > .05). Significant differences were noted by the mechanism of injury subgroups between complex injures (74%) as compared to lacerations (85%) or neuroma resections (94%) (p = .03) and by gap length between the <15 mm and 50–70 mm gap subgroups, 91 and 69% MR, respectively (p = .01). Results were comparable to historical literature for nerve autograft and exceed that of conduit.ConclusionsThese findings provide clinical evidence to support the continued use of PNA up to 70 mm in sensory, mixed and motor nerve repair throughout the body and across a broad patient population.
The impact of transferred vascularized toe joint length on motion arc of reconstructed finger proximal interphalangeal joints: a cadaveric study
Vascularized toe joint transfer for finger proximal interphalangeal joint reconstruction can result in sub-optimal arc of motion and extension lag due to inappropriate intercalated bony segment length. We investigated the impact of intercalated segment length on passive arc of motion and extension lag of the reconstructed proximal interphalangeal joint. Cadaveric intercalated joint grafts were harvested from lesser toes and transferred to cadaveric fingers. The pre-determined finger proximal interphalangeal joint defect size was 2 cm. Three different intercalated segment lengths were inserted and resulting proximal interphalangeal joint arc of motion and extension lag were measured. The average arc of motion of finger proximal interphalangeal joints was 81° and 54° for toe proximal interphalangeal joints. Long intercalated segments had an average arc of motion of 30° with 32° extension lag. Equal-length intercalated segments had an average 49° arc of motion with 15° extension lag. Short intercalated segments had an average arc of motion of 71° with 8° extension lag. Shorter intercalated segments provide the greatest reduction in extension lag.