Back to Authors

Bite, Uldis

Mayo Clinic

Mayo Clinic

Citations 41

Presentation of calcinosis cutis 35 years after silicone nasal implant reconstruction
Antezana, Luis A. , Mohan, Anita T. , Bite, Uldis, Antezana, Luis

BMJ Case Reports | February 1, 2021 | Volume: 14 | Issue: 2 | Pages: e239766

10.1136/bcr-2020-239766 Get It

Surgical and Patient-Reported Outcomes in Patients With PEEK Versus Titanium Cranioplasty Reconstruction
Taslakian, Editt N. , Banuelos, Joseph, Bite, Uldis, Sharaf, Basel , Abu-Ghname, Amjed, Sharaf, Basel A , Asaad, Malke , Abu‐Ghname, Amjed , Mardini, Samir , Gompel, Jamie J. Van

Journal of Craniofacial Surgery | October 18, 2020 | Volume: 32 | Issue: 1 | Pages: 193-197

10.1097/scs.0000000000007192 Get It

Background: Several materials are available for cranioplasty reconstruction and consensus regarding the ideal material is lacking. The goal of this study is to present surgical and patient-reported outcomes with PEEK versus Titanium alloplastic cranioplasty. Methods: A retrospective review of all patients who underwent alloplastic cranioplasty with PEEK or Titanium from 2010 to 2017 was conducted. Patient demographics and complications were abstracted and analyzed. Information regarding patient-reported outcomes was collected through a telephone survey. Results: A total of 72 patients (median age 55 years) who underwent 77 cranioplasties were identified (38% PEEK, n = 29; 62% Titanium, n = 48). Overall complication rates were similar between the PEEK (24%, n = 7) and Titanium groups (23%, n = 11), P = 0.902. Similarly, implant failure was similar between the 2 groups (7% in PEEK (n = 2), 13% in Titanium (n = 6), P = 0.703). History of radiation was associated with increased rate of infection in patients with Titanium mesh cranioplasty (38% in radiated patients (n = 3), 3% in nonradiated patients (n = 1), P = 0.012) but not PEEK implants (0% infection rate in radiated patients (n = 0), 15% in nonradiated patients (n = 4), P = 1.000). A total of 24 patients (33% response rate) participated in the telephone survey. All PEEK cranioplasty patients who responded to our survey (n = 13) reported good to excellent satisfaction, while 72% of our titanium mesh cohort (n = 8) described good or excellent satisfaction and 27% (n = 3) reported acceptable result. Conclusion: Cranial reconstruction is associated with high satisfaction among cranioplasty patients with PEEK or Titanium showing comparable complications, failure, and patient-reported satisfaction rates. Patients with history of radiotherapy demonstrated a higher infection rate when titanium mesh was used.
Eye-Tracking Technology in Plastic and Reconstructive Surgery: A Systematic Review
Asaad, Malke , Al-Mouakeh, Ahmad , Manjouna, Mohamad Baraa, Nashed, Mohammad, Rajesh, Aashish , Boonipat, Thanapoom , Bite, Uldis, Dey, Jacob K.

Aesthetic Surgery Journal | February 3, 2020 | Volume: 40 | Issue: 9 | Pages: 1022-1034

10.1093/asj/sjz328 Get It

Abstract Background The use of eye-tracking technology in plastic surgery has gained popularity over the past decade due to its ability to assess observers’ visual preferences in an objective manner. Objectives The goal of this study was to provide a comprehensive review of eye-tracking studies in plastic and reconstructive surgery, which can aid in the design and conduct of high-quality eye-tracking studies. Methods Through application of Preferred Reporting Items for Systematic review and Meta-Analysis (PRISMA) guidelines, a comprehensive search of articles published on eye-tracking across several databases was conducted from January 1946 to January 2019. Inclusion criteria included studies evaluating the use of eye-tracking technology in the field of plastic and reconstructive surgery. The resulting publications were screened by 2 independent reviewers. Results A total of 595 articles were identified, 23 of which met our inclusion criteria. The most common application of eye-tracking was to assess individuals with cleft lip/palate (9 studies). All 19 studies that evaluated fixation patterns among conditions vs controls reported significant differences between the 2 groups. Five out of 7 studies assessing visual data between preoperative and postoperative patients identified significant differences between the preoperative and postoperative groups, whereas 2 studies did not. Nine studies examined the relation between severity indices, attractiveness scores, or personality ratings and gaze patterns. Correlation was found in 7 out of the 9 studies. Conclusions This systematic review demonstrates the utility of eye-tracking technology as a quantifiable objective assessment and emerging research tool for evaluating outcomes in several domains of plastic and reconstructive surgery.
Objective Outcomes in Upper Blepharoplasty
Boonipat, Thanapoom , Charaffadine, Ali, Fleming, Kevin D., Bite, Uldis, Stotland, Mitchell A. , Abu‐Ghname, Amjed , Fleming, Kevin K.

Plastic and Reconstructive Surgery - Global Open | September 10, 2019 | Volume: 7 | Issue: 8S-1 | Pages: 137-138

10.1097/01.gox.0000585028.07793.16 Get It

Reconstruction of Oncologic Sternectomy Defects: Lessons Learned from 60 Cases at a Single Institution
Banuelos, Joseph, Bite, Uldis, Moran, Steven L. , Bakri, Karim , Pairolero, Peter C., Arnold, Philip G., Sharaf, Basel , Abu-Ghname, Amjed, Blackmon, Shanda H, Shen, Robert, Allen, Mark S. , Abu‐Ghname, Amjed , Blackmon, Shanda , Shen, Robert K. , Sharaf, Basel A

Plastic and Reconstructive Surgery - Global Open | July 29, 2019 | Volume: 7 | Issue: 7 | Pages: e2351

10.1097/gox.0000000000002351 Get It

Background: Oncologic sternectomy results in complex defects where preoperative planning is paramount to achieve best reconstructive outcomes. Although pectoralis major muscle flap (PMF) is the workhorse for sternal soft tissue coverage, additional flaps can be required. Our purpose is to evaluate defects in which other flaps beside PMF were required to achieve optimal reconstruction. Methods: A retrospective review of consecutive patients at our institution who underwent reconstruction after sternal tumor resection was performed. Demographics, surgical characteristics, and outcomes were evaluated. Further analysis was performed to identify defect characteristics where additional flaps to PMF were needed to complete reconstruction. Results: In 11 years, 60 consecutive patients were identified. Mean age was 58 (28–81) years old, with a mean follow-up of 40.6 (12–64) months. The majority were primary sternal tumors (67%) and the mean defect size was 148 cm2 (±81). Fourteen (23%) patients presented with postoperative complications, and the 30-day mortality rate was 1.6%. In 19 (32%) cases, additional flaps were required; the most common being the rectus abdominis muscle flaps. Larger thoracic defects (P = 0.011) and resections involving the inferior sternum (P = 0.021) or the skin (P = 0.011) were more likely to require additional flaps. Conclusions: Reconstruction of oncologic sternal defects requires a multidisciplinary team approach. Larger thoracic defects, particularly those that involve the skin and the inferior sternum, are more likely to require additional flaps for optimal reconstruction.
Lower Eyelid Reconstruction Using a Nasolabial, Perforator-based V-Y Advancement Flap
Harvey, Jamison A. , Garrity, James, Bite, Uldis, Harvey, Jamison Anne, Gibreel, Waleed

Annals of Plastic Surgery | August 16, 2018 | Volume: 82 | Issue: 1 | Pages: 46-52

10.1097/sap.0000000000001576 Get It

Background Reconstruction of the lower eyelid represents a unique challenge to the reconstructive surgeon. Studies evaluating the utility of the nasolabial V-Y advancement flap in lower eyelid reconstruction are limited and techniques to optimize outcomes following eyelid reconstruction with this technique are not well described. We seek to evaluate our experience and outcomes with lower eyelid reconstruction using the nasolabial perforator-based V-Y advancement flap. Methods After institutional review board approval, medical charts of all patients who underwent lower eyelid reconstruction using the nasolabial perforator-based V-Y advancement flap between February 2013 and October 2017 were reviewed. Data regarding etiology, location of the lesion, lower eyelid defect, methods of reconstruction, postoperative complications, and follow up duration were collected and analyzed. Results Over the study period, 5 patients (3 male) underwent lower eyelid reconstruction after oncologic resection of melanoma (n = 1) and nonmelanoma (n = 4) skin cancer using the nasolabial perforator-based V-Y advancement flap at a mean age of 69 years (range, 56–82 years). Median follow-up duration was 5.9 months (interquartile range, 2.25–25.9). A mean of 5.4 (range, 2–10) perforators were included in the initial flap design. After completion of flap dissection and perforator division, a mean of 4.4 (range, 2–7) perforators were preserved and included in the flap. All flaps demonstrated clinical viability with no cases of partial or total flap loss. One patient developed an asymptomatic ectropion during the follow-up period. Conclusions The nasolabial, perforator-based V-Y advancement flap is a reliable reconstructive method for lower eyelid defects.
Free Tissue Transfers for Head and Neck Reconstruction in Patients with End-Stage Renal Disease on Dialysis: Analysis of Outcomes Using the Taiwan National Health Insurance Research Database
Ciudad, Pedro , Sharaf, Basel , Martinez‐Jorge, Jorys, Moran, Steven, Mardini, Samir , Chen, Hung‐Chi , Bite, Uldis, Cheng, Hsu‐Tang , Manrique, Oscar J. , Chen, Hung‐Chi , Martinez-Jorge, Jorys, Cheng, Hsu-Tang , Sharaf, Basel A

Journal of Reconstructive Microsurgery | June 16, 2017 | Volume: 33 | Issue: 08 | Pages: 587-591

10.1055/s-0037-1603739 Get It

Background Patients diagnosed with end-stage renal disease (ESRD) are increasing at around 5% annually. Some of these patients will require free tissue transfers to reconstruct their body after trauma or cancer resection. Comorbidities can increase the level of complexity during reconstruction. Aim Our goal is to describe the outcomes of ESRD patients under dialysis who underwent free tissue transfer for head and neck reconstruction. Methods Two cohorts were analyzed: ESRD group on dialysis and a non-ESRD control group after free tissue transfer for head and neck reconstruction. Postoperative complications and mortality were recorded. For coexisting comorbidities, we determine the presence of diabetes mellitus (DM) and peripheral vascular disease (PVD). Results In this study, 85 cases with ESRD on dialysis and 841 controls were analyzed. Most patients were aged ≤ 65 years (82.5%) and nearly 92.9% of them were men. Types of head and neck cancer were neoplasm of other and unspecified parts of the mouth followed by neoplasm of tongue, the gingiva, hypopharynx, and floor of mouth. Patients with ESRD tended to have higher rates of DM and PVD (p < 0.001) and were significantly associated with an increased risk of stroke and increased risk of 30-day mortality. However, there was no significant difference regarding flap failure among groups. Conclusion Despite greater preoperative risk factors, patients with renal failure on hemodialysis do not appear to have a higher rate of free flap failure following head and neck reconstruction. However, other complications can be minimized by optimizing patient's medical condition to succeed with this reconstructive effort.
A Long-Term Clinical and Cephalometric Study of Cleft Lip and Palate Patients following Intraoral Maxillary Quadrangular Le Fort I Osteotomy
Karabekmez, Furkan Erol , Keller, Eugene E., Stork, James T., Regennitter, Frederick J., Bite, Uldis

The Cleft Palate Craniofacial Journal | December 30, 2013 | Volume: 52 | Issue: 3 | Pages: 311-326

10.1597/13-095 Get It

Objective To evaluate the horizontal and vertical stability of the quadrangular Le Fort I in patients with congenital cleft lip and palate. Design Prospective longitudinal study. Patients A total of 15 congenital cleft lip and palate patients treated with the maxillary quadrangular Le Fort I were enrolled. Intervention Lateral cephalometric radiographic examinations were obtained preoperatively, early postoperatively, and late postoperatively for four dental and skeletal landmarks. A questionnaire regarding patients' satisfaction with treatment and functional/cosmetic outcomes (airway, speech, mastication) was administered. Main Outcome Measures Surgical horizontal and vertical movement, late postsurgical horizontal and vertical movement, and surgical and postsurgical movement in relation to age and cleft type were evaluated using Spearman correlation coefficients, Wilcoxon signed rank tests, and Mann-Whitney tests. Results Surgical horizontal movements of all measured points showed significant changes. Significant differences of postsurgical horizontal movement were observed in younger patients versus adult patients. Significant differences of postsurgical horizontal movement were observed in unilateral cleft patients versus bilateral cleft patients. A high percentage of patients showed significant functional improvement in nasal airflow, speech, mastication, temporomandibular joint function, and mouth versus nose breathing. Conclusions The quadrangular Le Fort I is a functionally stable and a surgically predictable procedure for cleft lip and palate patients who present with midface deficiency. Patients under the age of 18 at the time of the osteotomy had a higher relapse rate than patients over 18 years of age. Younger patients who need surgery should be advised regarding the increased risk of skeletal relapse. Patients' satisfaction was high in all aesthetic- and function-related items on the questionnaire.
Microbial Biofilms and Breast Tissue Expanders
Karau, Melissa J. , Greenwood‐Quaintance, Kerryl E. , Schmidt, Suzannah M., Tran, Nho V. , Convery, Phyllis A., Jacobson, Steven R., Bite, Uldis, Clay, Ricky P., Petty, Paul M., Johnson, C. H. , Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin

BioMed Research International | July 16, 2013 | Volume: 2013 | Issue: No issue available | Pages: 1-6

10.1155/2013/254940 Get It

We previously developed and validated a vortexing-sonication technique for detection of biofilm bacteria on the surface of explanted prosthetic joints. Herein, we evaluated this technique for diagnosis of infected breast tissue expanders and used it to assess colonization of breast tissue expanders. From April 2008 to December 2011, we studied 328 breast tissue expanders at Mayo Clinic, Rochester, MN, USA. Of seven clinically infected breast tissue expanders, six (85.7%) had positive cultures, one of which grewPropionibacteriumspecies. Fifty-two of 321 breast tissue expanders (16.2%, 95% CI, 12.3–20.7%) without clinical evidence of infection also had positive cultures, 45 growingPropionibacteriumspecies and ten coagulase-negative staphylococci. While vortexing-sonication can detect clinically infected breast tissue expanders, 16 percent of breast tissue expanders appear to be asymptomatically colonized with normal skin flora, most commonly,Propionibacteriumspecies.
Pilot Study of Association of Bacteria on Breast Implants with Capsular Contracture
Pozo, José Luís del , Tran, Nho V. , Petty, Paul M., Johnson, C. H. , Walsh, Molly F., Bite, Uldis, Clay, Ricky P., Mandrekar, Jayawant N. , Piper, Kerryl E., Steckelberg, James M., Patel, Robin , Patel, Robin

Journal of Clinical Microbiology | March 5, 2009 | Volume: 47 | Issue: 5 | Pages: 1333-1337

10.1128/jcm.00096-09 Get It

ABSTRACT Capsular contracture is the most common and frustrating complication in women who have undergone breast implantation. Its cause and, accordingly, treatment and prevention remain to be elucidated fully. The aim of this prospective observational pilot study was to test the hypothesis that the presence of bacteria on breast implants is associated with capsular contracture. We prospectively studied consecutive patients who underwent breast implant removal for reasons other than overt infection at the Mayo Clinic from February through September 2008. Removed breast implants were processed using a vortexing/sonication procedure and then subjected to semiquantitative culture. Twenty-seven of the 45 implants collected were removed due to significant capsular contracture, among which 9 (33%) had ≥20 CFU bacteria/10 ml sonicate fluid; 18 were removed for reasons other than significant capsular contracture, among which 1 (5%) had ≥20 CFU/10 ml sonicate fluid ( P = 0.034). Propionibacterium species, coagulase-negative staphylococci, and Corynebacterium species were the microorganisms isolated. The results of this study demonstrate that there is a significant association between capsular contracture and the presence of bacteria on the implant. The role of these bacteria in the pathogenesis of capsular contracture deserves further study.