Background and Purpose— We performed a meta-analysis of published studies on the endovascular treatment of very small intracranial aneurysms, including 71 patients treated at our institution. Methods— We conducted a computerized MEDLINE search of the literature for reports on the treatment of intracranial aneurysms with a maximum dimension of ≤3 mm by using the search terms “small,” “tiny,” “intracranial aneurysm,” “endovascular,” and “coil.” A total of 7 studies, including our institution’s consecutive case series of 71 intracranial aneurysms, were included in this study. We extracted information regarding intraoperative complications, procedural mortality and morbidity, immediate- and long-term angiographic outcomes, and retreatment rate. The meta-analysis was performed with the statistical package Comprehensive Meta-Analysis. Results— Approximately 61% of the aneurysms in this meta-analysis presented as ruptured, whereas 39% of the aneurysms were unruptured. Procedural rupture rates for very small aneurysms was 8.3% (95% CI, 6.0% to 11.4%). The mortality rate due to procedural rupture was 2.4% (95% CI, 1.2% to 4.7%). The morbidity rate due to thromboembolic complications was 1.9% (95% CI, 0.9% to 3.9%). Subarachnoid hemorrhage within 1 month of treatment occurred in 1.6% (95% CI, 0.6% to 3.7%) of cases. There was no statistically significant difference between unruptured and ruptured aneurysms for any of these outcomes. Conclusion— Our meta-analysis suggests that treatment of very small aneurysms is feasible and effective in >90% of treated aneurysms. However, the risk of periprocedural rupture is higher than that reported for larger aneurysms. Similarly, the combined rate of periprocedural mortality and morbidity is not negligible (7.3%) and should be considered when considering the best therapeutic option for these aneurysms.
Spinal extradural arteriovenous malformations with parenchymal drainage: venous drainage variability and implications in clinical manifestations
Object Although nontraumatic spinal arteriovenous malformations and fistulas (AVMs and AVFs) restricted to the epidural space are rare, they can lead to significant neurological morbidity. Careful diagnostic imaging is essential to their detection and the delineation of the pathological anatomy. Aggressive endovascular and open operative treatment can provide arrest and reversal of neurological deficits. Methods The authors report on 6 cases of extradural AVMs/AVFs causing progressive myelopathy. Clinical findings, diagnostic evaluation, treatment, and outcome are discussed. Special consideration is given to the anatomy of the lesions and the operative techniques used to treat them. A review of the literature concerning extradural vascular malformations is also presented. Results All 6 cases of extradural AVMs had an extradural fistulous location with intradural medullary venous drainage. These cases illustrate progressive myelopathy through cord venous congestion (hypertension) that can be caused by an extradural nidus or fistula. In 4 cases, a large epidural lake was identified on angiography. At surgery, the epidural lake was obliterated and medullary drainage interrupted. All patients had stabilization of their neurological deficits and successful obliteration of the AVM/AVF was obtained. Conclusions Extradural AVMs and AVFs are a poorly described entity with published clinical experience limited to sporadic case reports and small series. Although these lesions have a purely extradural location of arteriovenous shunting and early venous drainage, they can be responsible for acute and progressive neurological symptoms similar to those caused by their dural-based intradural counterparts. With careful imaging recognition of the pathological anatomy, surgical and endovascular techniques can be used for the treatment of extradural AVMs affording effective and durable obliteration with stabilization or reversal of neurological symptoms. Venous drainage directly correlates the pathologic mechanisms of presentation. Specific attention must be paid intraoperatively to the epidural lake common to both variants so that recurrence is avoided.
VANISHING ANEURYSM IN PRETRUNCAL NONANEURYSMAL SUBARACHNOID HEMORRHAGE
Background and Purpose— Even though endovascular coils have been widely used for the treatment of intracranial aneurysms, the cellular and molecular responses of aneurysms to the coils after embolization remain poorly understood. The aim of the present study was to understand the mechanism of apoptosis in aneurysms embolized with platinum coils in the rabbit model of elastase-induced aneurysms. Methods— Elastase-induced saccular aneurysms were created at the origin of the right common carotid artery in 30 rabbits. Aneurysms were allowed to mature for 8 weeks, after which 20 aneurysms were embolized with platinum coils by endovascular means. After 2 (n=10) and 4 (n=10) weeks of implantation, aneurysm samples harboring coils were harvested for apoptotic studies. The remaining 10 uncoiled aneurysms were used as controls; additional controls included the left common carotid artery, which had not undergone any surgical procedure. Control samples were harvested at 12 weeks after aneurysm creation. Results— Expression of procaspases-3, -8, and -9 was elevated in coiled aneurysms embolized with platinum coils at both time points when compared with uncoiled aneurysms and the left common carotid artery. Cleaved caspases-3, -8, and -9 were found to be expressed only at 4 weeks after embolization. Cells within the aneurysm cavity were terminal dUTP nick end-labeling–positive at 4 weeks only. These apoptotic cells were identified as smooth muscle actin–positive cells. Expression of tumor necrosis-α was high in coiled aneurysms when compared with controls. There was no significant difference in the expression of Fas ligand among groups. Decreased expression of antiapoptotic proteins Bcl-2 and phospho-Bad, as well as increased expression of proapoptotic proteins Bax and Bid, was observed in coiled aneurysms at both time points. Conclusions— Activation of apoptosis in aneurysms after embolization with platinum coils is induced by both tumor necrosis factor-α–mediated extrinsic and Bcl-2-mediated intrinsic pathways.
A New Endoluminal, Flow-Disrupting Device for Treatment of Saccular Aneurysms
Background and Purpose— We report a preclinical study of a new endoluminal device for aneurysm occlusion to test the hypothesis that the device, even without use of intrasaccular coil placement, could occlude saccular aneurysms without causing substantial parent artery compromise or compromise of adjacent, small branch arteries. Methods— The Pipeline Neuroendovascular Device (Pipeline NED; Chestnut Medical Technologies, Inc) is a braided, tubular, bimetallic endoluminal implant aimed at occlusion of saccular aneurysms through flow disruption along the aneurysm neck. The device was implanted across the necks of 17 elastase-induced aneurysms in the New Zealand white rabbit model and followed for 1 month (n=6), 3 months (n=5), and 6 months (n=6). In each subject, a second device was implanted in the abdominal aorta to cover the origins of lumbar arteries. Aneurysm occlusion rates by angiography (grade 1, complete occlusion; grade 2, near-complete occlusion; and grade 3, incomplete occlusion) were documented. Percent area stenosis of the parent arteries was calculated. Presence of distal emboli in the downstream vessels in the parent artery and branch artery stenosis or occlusion was noted. Results— Grades 1, 2, and 3 occlusion rates were noted in 9 (53%), 6 (35%), and 2 (12%) of 17 aneurysms, respectively, indicating an 88% rate of complete or near complete occlusion. No cases of branch artery occlusion or distal emboli in the downstream vessels of the parent artery, specifically the subclavian artery, were seen. Parent artery compromise from neointimal hyperplasia was minimal in most cases. Conclusions— The Pipeline NED is a trackable, bio- and hemocompatible device able to occlude saccular aneurysms with preservation of the parent artery and small, adjacent branch vessels.
Specificity of MR Angiography as a Confirmatory Test for Carotid Artery Stenosis: Is It Valid?
Background and Purpose— The purpose of this study was to determine whether implanting exogenous fibroblasts on platinum coils could enhance intra-aneurysmal fibrosis. Hypotheses included: (1) fibroblast-coated (FBC) platinum coils can improve angiographic results after embolization; and (2) FBC platinum coils can accelerate histological healing of embolized aneurysms. Methods— Experimental aneurysms in rabbits were embolized with control platinum coils (n=18) or FBC coils (n=18). Subjects were euthanized at 14 days, 1 month, 3 months and 6 months after implantation. Digital subtraction angiography was used to evaluate stability after embolization. Histological samples were examined with a grading system (range, 0 to 12) based on neck and dome healing. Results— Histology total scores and fibrosis ratio at 14 days were significantly greater in the FBC coil group compared with controls (6.6±1.9 versus 2.5±1.1, 1.2±0.6% versus 0.2±0.3%, respectively; P =0.0090). Cavities embolized with FBC coils showed cellular proliferation and thrombus organization, with an endothelialized membrane bridging the neck. There were no differences between groups in the later timepoints. The FBC coil group showed radiographic stability in 11 (61%) cases, coil compaction in 2 (11%) cases, and progressive occlusion in 5 (28%) cases. No progressive occlusion was seen in controls; 3 (17%) of 18 control cases exhibited coil compaction ( P =0.0546). Conclusions— FBC coils can accelerate early histological healing compared with control coils in the rabbit aneurysm model.
Dimpled Appearance of a Posterior Communicating Artery Saccule: An Angiographic Indicator of Arterial Infundibula