Back to Authors

Arunachalam, Shivaram P.

https://orcid.org/0000-0003-3251-5415

Mayo Clinic

Mayo Clinic

Citations 98

Comparison of Multiscale Frequency Characteristics of Normal Phonocardiogram With Diseased Heart States
Sundaram, Divaakar Siva Baala, Kapoor, Anoushka, Xie, Jackie, Xu, Natalie , Moorthy, P. Krishna, Balasubramani, Rogith, Shivaram, Suganti, Muthyala, Anjani, Arunachalam, S P , Xu, Natalie C., Moorthy, Prissha Krishna, Arunachalam, Shivaram P.

2020 Design of Medical Devices Conference | August 6, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2020-9090 Get It

Abstract Phonocardiogram (PCG) signals are electrical recording of heart sounds containing vital information of diagnostic importance. Several signal processing methods exist to characterize PCG, however suffers in terms of sensitivity and specificity in accurately discriminating normal and abnormal heart sounds. Recently, a multiscale frequency (MSF) analysis of normal PCG was reported to characterize subtle frequency content changes in PCG which can aid in differentiating normal and abnormal heart sounds. In this work, it was hypothesized that MSF can discriminate normal PCG signal compared to an artifact, PCG with extra systolic heart sounds and murmur based on their varying frequency content. Various samples of PCG with normal and abnormal heart sounds were obtained from Peter Bentley Heart Sounds Database sampled at 44.1 kHz for analysis. The signal was filtered using a 4th order Butterworth lowpass filter with cutoff frequency at 200 Hz to remove higher frequency noise and MSF estimation was performed on the filtered dataset using custom MATLAB software. Mann-Whitney test was performed for statistical significance at p < 0.05. Results indicate that MSF successfully discriminated normal and abnormal heart sounds, which can aid in PCG classification with more sophisticated analysis. Validation of this technique with larger dataset is required.
Patient Satisfaction in the Emergency Department Is Influenced by Total Length of Stay: An RFID Based Feasibility Study
Albertson, Sabrina M., Sır, Mustafa Y. , Nestler, David M. , Heaton, Heather A. , Marisamy, Gomathi, Arunachalam, S P , Arunachalam, Shivaram P. , Pasupathy, Kalyan S.

2020 Design of Medical Devices Conference | August 6, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2020-9078 Get It

Abstract Real-time location systems (RTLS) such as radio frequency identification (RFID) have been shown to improve safety, save cost, and increase patient satisfaction in a healthcare setting especially in the emergency department (ED). Hospital administrators have realized the potential of these applications for improved workflow and operations and are positively adopting it despite the substantial implementation costs of such technologies. Our group has reported several studies with RFID data in the ED showing the relationship between RFID determined patient contact times and length of stay (LOS). In this study, we use ED RFID data to determine the relationship between the total LOS in ED to the overall patient satisfaction obtained from a survey report. ED survey results from 35 questions were obtained from patients after discharge. An observational cohort study was performed in the ED using RFID data from Jan 1 – Dec 31, 2017 matched with the ED survey participants. A total of 2595 survey data was used for logistic regression analysis with the RFID data. Results show that higher treatment LOS influenced overall patient satisfaction negatively. The results provide new insights into designing ideal patient-care team interactions to reduce overall LOS while providing optimal ED care, thereby improving patient satisfaction.
Robust Discrimination of Phonocardiogram Signal with Normal Heart Sounds and Murmur Using a Multiscale Frequency Analysis
Sundaram, Divaakar Siva Baala, Shivaram, Suganti, Balasubramani, Rogith, Muthyala, Anjani, Arunachalam, S P , Arunachalam, Shivaram P.

2019 IEEE Healthcare Innovations and Point of Care Technologies, (HI-POCT) | January 21, 2020 | Volume: No volume available | Issue: No issue available | Pages: 107-110

10.1109/hi-poct45284.2019.8962884 Get It

Profiling Multiscale Frequency State of Normal Phonocardiogram: Feasibility Study
Sundaram, Divaakar Siva Baala, Anjani, Muthyala, Balasubramani, Rogith, Shivaram, Suganti, Karki, Susan, Arunachalam, S P , Karki, Susan, Arunachalam, Shivaram P.

2019 Design of Medical Devices Conference | July 19, 2019 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2019-3301 Get It

Phonocardiogram (PCG) signals contain very important information regarding the heart condition. Recently, several automatic detection algorithms have been explored to profile the characteristics of heart sounds to aid in disease diagnosis. However, many of these methods has been demonstrated only on clean signals with limited test data and variety of PCG signals that can accurately provide information of diagnostic importance with higher sensitivity and specificity. In this work, we propose to characterize the multiscale frequency state of the normal PCG signals that can aid in accurate profiling of PCG to discriminate from pathological conditions.
Waveguide effects and implications for cardiac magnetic resonance elastography: A finite element study
Manduca, Armando , Rossman, Timothy, Lake, David S. , Glaser, Kevin J. , Arani, Arvin , Rossman, Phillip J. , Trzasko, Joshua D. , Dragomir‐Daescu, Dan , Araoz, Philip A. , Manduca, A , Arunachalam, S P , Arani, Arvin , Arunachalam, Shivaram P. , Ehman, Richard L.

NMR in Biomedicine | August 13, 2018 | Volume: 31 | Issue: 10 | Pages: No page available

10.1002/nbm.3996 Get It

Magnetic resonance elastography (MRE) is increasingly being applied to thin or small structures in which wave propagation is dominated by waveguide effects, which can substantially bias stiffness results with common processing approaches. The purpose of this work was to investigate the importance of such biases and artifacts on MRE inversion results in: (i) various idealized 2D and 3D geometries with one or more dimensions that are small relative to the shear wavelength; and (ii) a realistic cardiac geometry. Finite element models were created using simple 2D geometries as well as a simplified and a realistic 3D cardiac geometry, and simulated displacements acquired by MRE from harmonic excitations from 60 to 220 Hz across a range of frequencies. The displacement wave fields were inverted with direct inversion of the Helmholtz equation with and without the application of bandpass filtering and/or the curl operator to the displacement field. In all geometries considered, and at all frequencies considered, strong biases and artifacts were present in inversion results when the curl operator was not applied. Bandpass filtering without the curl was not sufficient to yield accurate recovery. In the 3D geometries, strong biases and artifacts were present in 2D inversions even when the curl was applied, while only 3D inversions with application of the curl yielded accurate recovery of the complex shear modulus. These results establish that taking the curl of the wave field and performing a full 3D inversion are both necessary steps for accurate estimation of the shear modulus both in simple thin‐walled or small structures and in a realistic cardiac geometry when using simple inversions that neglect the hydrostatic pressure term. In practice, sufficient wave amplitude, signal‐to‐noise ratio, and resolution will be required to achieve accurate results.
Multiscale Entropy Technique Discriminates Single Lead ECG’s With Normal Sinus Rhythm and Sleep Apnea
Shivaram, Suganti, Muthyala, Anjani, Meghji, Zahara, Karki, Susan, Arunachalam, S P , Arunachalam, Shivaram P.

2018 Design of Medical Devices Conference | July 30, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2018-6948 Get It

Sleep apnea is characterized by abnormal interruptions in breathing during sleep due to partial or complete airway obstructions affecting middle-aged men and women on an estimated ∼4% of the population [1]. While the disorder is clinically manageable to relieve patients, the challenge occurs with diagnosis, with many patients going undiagnosed leading to further complications such as ischemic heart diseases, stroke etc. Sleep apnea also significantly affects the quality of day to day life causing sleepiness and fatigue. Polysomnography (PSG) technique is currently a used for detecting sleep apnea which is a comprehensive sleep test to diagnose sleep disorders by recording brain waves, the oxygen level in the blood, heart rate, breathing, eye and leg movements during the study. However, PSG test is very expensive, requires patients to stay overnight and is known to cause inconvenience to the patients.
MRI feature tracking strain is prognostic for all-cause mortality in AL amyloidosis
Illman, Jeffery E., Arani, Arvin , Chang, Ian C , Glockner, James F., Grogan, Martha , Araoz, Philip A. , Arunachalam, S P , Arani, Arvin , Chang, Ian Cheng-Yi , Dispenzieri, Angela , Grogan, Martha , Araoz, Philip A , Arunachalam, Shivaram P. , Dispenzieri, Angela

Amyloid | May 7, 2018 | Volume: 25 | Issue: 2 | Pages: 101-108

10.1080/13506129.2018.1465406 Get It

Improved Multiscale Entropy Technique with Nearest-Neighbor Moving-Average Kernel for Nonlinear and Nonstationary Short-Time Biomedical Signal Analysis
Mulpuru, Siva K. , Friedman, Paul A. , Tolkacheva, Elena G. , Arunachalam, S P , Tolkacheva, E G , Arunachalam, Shivaram P. , Kapa, Suraj

Journal of Healthcare Engineering | March 5, 2018 | Volume: 2018 | Issue: No issue available | Pages: 1-13

10.1155/2018/8632436 Get It

Analysis of biomedical signals can yield invaluable information for prognosis, diagnosis, therapy evaluation, risk assessment, and disease prevention which is often recorded as short time series data that challenges existing complexity classification algorithms such as Shannon entropy (SE) and other techniques. The purpose of this study was to improve previously developed multiscale entropy (MSE) technique by incorporating nearest-neighbor moving-average kernel, which can be used for analysis of nonlinear and non-stationary short time series physiological data. The approach was tested for robustness with respect to noise analysis using simulated sinusoidal and ECG waveforms. Feasibility of MSE to discriminate between normal sinus rhythm (NSR) and atrial fibrillation (AF) was tested on a single-lead ECG. In addition, the MSE algorithm was applied to identify pivot points of rotors that were induced in ex vivo isolated rabbit hearts. The improved MSE technique robustly estimated the complexity of the signal compared to that of SE with various noises, discriminated NSR and AF on single-lead ECG, and precisely identified the pivot points of ex vivo rotors by providing better contrast between the rotor core and the peripheral region. The improved MSE technique can provide efficient complexity analysis of variety of nonlinear and nonstationary short-time biomedical signals.
Cardiac MR elastography using reduced‐FOV, single‐shot, spin‐echo EPI
Sui, Yi , Arunachalam, Shivaram P. , Arani, Arvin , Trzasko, Joshua D. , Young, Phillip M. , Glockner, James F., Glaser, Kevin J. , Lake, David S. , McGee, Kiaran P. , Rossman, Phillip J. , Araoz, Philip A. , Arunachalam, S P , Arani, Arvin , Manduca, Armando , Ehman, Richard L. , Sui, Yi

Magnetic Resonance in Medicine | December 1, 2017 | Volume: 80 | Issue: 1 | Pages: 231-238

10.1002/mrm.27029 Get It

PurposeTo implement a reduced field of view (rFOV) technique for cardiac MR elastography (MRE) and to demonstrate the improvement in image quality of both magnitude images and post‐processed MRE stiffness maps compared to the conventional full field of view (full‐FOV) acquisition.MethodsWith Institutional Review Board approval, 17 healthy volunteers underwent both full‐FOV and rFOV cardiac MRE scans using 140‐Hz vibrations. Two cardiac radiologists blindly compared the magnitude images and stiffness maps and graded the images based on several image quality attributes using a 5‐point ordinal scale. Fisher's combined probability test was performed to assess the overall evaluation. The octahedral shear strain‐based signal‐to‐noise ratio (OSS‐SNR) and median stiffness over the left ventricular myocardium were also compared.ResultsOne volunteer was excluded because of an inconsistent imaging resolution during the exam. In the remaining 16 volunteers (9 males, 7 females), the rFOV scans outperformed the full‐FOV scans in terms of subjective image quality and ghosting artifacts in the magnitude images and stiffness maps, as well as the overall preference. The quantitative measurements showed that rFOV had significantly higher OSS‐SNR (median: 1.4 [95% confidence interval (CI): 1.2–1.5] vs. 2.1 [95% CI: 1.8–2.4]), P < 0.05) compared to full‐FOV. Although no significant change was found in the median myocardial stiffness between the 2 scans, we observed a decrease in the stiffness variation within the myocardium from 2.1 kPa (95% CI: [1.9, 2.3]) to 1.9 kPa (95% CI: [1.7, 2.0]) for full‐FOV and rFOV, respectively (P < 0.05) in a subgroup of 7 subjects with ghosting present in the myocardium.ConclusionThis pilot volunteer study demonstrated that rFOV cardiac MRE has the capability to reduce ghosting and to improve image quality in both MRE magnitude images and stiffness maps. Magn Reson Med 80:231–238, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
Robust Discrimination of Normal Sinus Rhythm and Atrial Fibrillation on ECG Using a Multiscale Frequency Technique
Arunachalam, Shivaram P. , Annoni, Elizabeth M., Mulpuru, Siva K. , Friedman, Paul A. , Tolkacheva, Elena G. , Arunachalam, S P , Kapa, Suraj

2017 Design of Medical Devices Conference | October 31, 2017 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2017-3302 Get It

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia affecting approximately 3 million Americans, and is a prognostic marker for stroke, heart failure and even death [1]. 12-lead electrocardiogram (ECG) is used to monitor normal sinus rhythm (NSR) and also detect AF. Although the persistent form of AF can be detected relatively easy, detecting paroxysmal AF is often a challenge since requiring continuous monitoring, which becomes expensive and cumbersome to collect lot of ECG data [1]. Several researchers have attempted to develop new methods to discriminate NSR and AF which are based on R-R interval analysis, linear methods, filtering, spectral analysis, statistical approaches such as entropy etc. which faces limitation of successfully detecting AF of all types with high sensitivity and specificity using short time ECG data [1–3]. The major issues with these approaches is that they often distort the ECG by several pre-processing steps with filters, do not provide reliable discrimination using short ECG time series data and many of them lack real-time capability that makes it difficult to trust the data for diagnosis and treatment. Both clinical and scientific communities recognize these difficulties and the necessity to develop novel methods that can enable accurate monitoring and detection of AF [2]. In addition, robust detection and classification algorithms are essential for delivering appropriate therapy for implantable cardioverter defibrillators (ICD) to provide lifesaving timely action. In this work, the authors propose and demonstrate the application of a multiscale frequency (MSF) approach [4] for accurate detection and discrimination between AF and NSR ECG traces taken from publically available Physionet database. The MSF approach takes into account the contribution from various frequencies in ECG and thus yield valuable information regarding the chaotic nature of AF. Therefore, we demonstrate that MSF can capture the complexity of AF which is associated with higher MSF value compared with NSR thus enabling robust discrimination e AF manifests itself with numerous chaotic frequencies within the body surface ECG,. We validate the feasibility of this technique to discriminate NSR from AF.