Background: Severe adolescent idiopathic scoliosis (AIS) can be treated with instrumented fusion, but the number of anchors needed for optimal correction is controversial. Methods: We conducted a multicenter, randomized study that included patients undergoing spinal fusion for single thoracic curves between 45° and 65°, the most common form of operatively treated AIS. Of the 211 patients randomized, 108 were assigned to a high-density screw pattern and 103, to a low-density screw pattern. Surgeons were instructed to use ≥1.8 implants per spinal level fused for patients in the high-implant-density group or ≤1.4 implants per spinal level fused for patients in the low-implant-density group. The primary outcome measure was the percent correction of the coronal curve at the 2-year follow-up. The power analysis for this trial required 174 patients to show equivalence, defined as a 95% confidence interval (CI) within a ±10% correction margin with a probability of 90%. Results: In the intention-to-treat analysis, the mean percent correction of the coronal curve was equivalent between the high-density and low-density groups at the 2-year follow-up (67.6% versus 65.7%; difference, −1.9% [95% CI: −6.1%, 2.2%]). In the per-protocol cohorts, the mean percent correction of the coronal curve was also equivalent between the 2 groups at the 2-year follow-up (65.0% versus 66.1%; difference, 1.1% [95% CI: −3.0%, 5.2%]). A total of 6 patients in the low-density group and 5 patients in the high-density group required reoperation (p = 1.0). Conclusions: In the setting of spinal fusion for primary thoracic AIS curves between 45° and 65°, the percent coronal curve correction obtained with use of a low-implant-density construct and that obtained with use of a high-implant-density construct were equivalent. Level of Evidence: Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.
What would be the annual cost savings if fewer screws were used in adolescent idiopathic scoliosis treatment in the US?
OBJECT There is substantial heterogeneity in the number of screws used per level fused in adolescent idiopathic scoliosis (AIS) surgery. Assuming equivalent clinical outcomes, the potential cost savings of using fewer pedicle screws were estimated using a medical decision model with sensitivity analysis. METHODS Descriptive analyses explored the annual costs for 5710 AIS inpatient stays using discharge data from the 2009 Kids’ Inpatient Database (Healthcare Cost and Utilization Project, Agency for Healthcare Research and Quality), which is a national all-payer inpatient database. Patients between 10 and 17 years of age were identified using the ICD-9-CM code for idiopathic scoliosis (737.30). All inpatient stays were assumed to represent 10-level fusions with pedicle screws for AIS. High screw density was defined at 1.8 screws per level fused, and the standard screw density was defined as 1.48 screws per level fused. The surgical return for screw malposition was set at $23,762. A sensitivity analysis was performed by varying the cost per screw ($600–$1000) and the rate of surgical revisions for screw malposition (0.117%–0.483% of screws; 0.8%–4.3% of patients). The reported outcomes include estimated prevented malpositioned screws (set at 5.1%), averted revision surgeries, and annual cost savings in 2009 US dollars, assuming similar clinical outcomes (rates of complications, revision) using a standard- versus high-density pattern. RESULTS The total annual costs for 5710 AIS hospital stays was $278 million ($48,900 per patient). Substituting a high for a standard screw density yields 3.2 fewer screws implanted per patient, with 932 malpositioned screws prevented and 21 to 88 revision surgeries for implant malposition averted, and a potential annual cost savings of $11 million to $20 million (4%–7% reduction in the total cost of AIS hospitalizations). CONCLUSIONS Reducing the number of screws used in scoliosis surgery could potentially decrease national AIS hospitalization costs by up to 7%, which may improve the safety and efficiency of care. However, such a screw construct must first be proven safe and effective.