Back to Authors

Thompson, Bithika

https://orcid.org/0000-0002-5650-0341

Mayo Clinic

Mayo Clinic in Arizona

Citations 27

MON-021 Patterns of Sharps Handling and Disposal Among Insulin Using Patients with Diabetes
Montoya, Jordan, Thompson, Bithika , Boyle, Mary , Leighton, Melinda E., Boyle, Mary, Cook, Curtiss B.

Journal of the Endocrine Society | May 10, 2019 | Volume: 3 | Issue: Supplement_1 | Pages: No page available

10.1210/js.2019-mon-021 Get It

Patient Perception and Satisfaction With Insulin Pump System: Pilot User Experience Survey
Bayuk, Mike, Karway, George , Corrette, Krystal, Groat, Danielle , Thompson, Bithika , Grando, Maria Adela , Cook, Curtiss B. , Grando, Adela

Journal of Diabetes Science and Technology | May 6, 2019 | Volume: 13 | Issue: 6 | Pages: 1142-1148

10.1177/1932296819843146 Get It

Background: The goal of this study was to assess patient perspectives and satisfaction with the MiniMed 670G insulin pump. Those participants who used the pump as part of a hybrid closed loop were also asked to provide their views on the automatic feature (auto mode). Methods: Adults with type 1 diabetes mellitus using the Medtronic™ 670G pump were asked about their experience with the device using a semi-structured survey developed by the research team. Responses were quantified to identify emergent themes. Results: Seventeen participants used the pump as part of a hybrid closed loop system, while four participants used the pump in combination with a nonintegrated continuous glucose monitoring system. Overall, participants indicated a high level of satisfaction with the pump (14/21) mostly because of improvements in blood glucose (BG) control (15/21). Least liked features were physical design and structure (6/21), frequency of user input (5/21), alert frequency (4/21), and difficulty of use (3/21). Those using the hybrid closed loop were satisfied with the auto mode feature (11/17), mostly because of improvements in BG control (9/17). The least liked features of the auto mode technology were that blood glucose levels remained elevated (5/17) and the frequency of alerts (4/17). Conclusion: Participants indicated a high level of satisfaction with the pump and its auto mode featured mostly because of improvements in BG control. They also pointed out some key aspects of the device that are of potential clinical or commercial relevance. Additional research is needed to further evaluate users' perspectives on this new device.
Comparing Real-Time Self-Tracking and Device-Recorded Exercise Data in Subjects with Type 1 Diabetes
Groat, Danielle , Kwon, Hyo, Thompson, Bithika , Grando, Maria Adela, Cook, Curtiss B. , Grando, Adela

Applied Clinical Informatics | December 26, 2018 | Volume: 09 | Issue: 04 | Pages: 919-926

10.1055/s-0038-1676458 Get It

Background Insulin therapy, medical nutrition therapy, and physical activity are required for the treatment of type 1 diabetes (T1D). There is a lack of studies in real-life environments that characterize patient-reported data from logs, activity trackers, and medical devices (e.g., glucose sensors) in the context of exercise. Objective The objective of this study was to compare data from continuous glucose monitor (CGM), wristband heart rate monitor (WHRM), and self-tracking with a smartphone application (app), iDECIDE, with regards to exercise behaviors and rate of change in glucose levels. Methods Participants with T1D on insulin pump therapy tracked exercise for 1 month with the smartphone app while WHRM and CGM recorded data in real time. Exercise behaviors tracked with the app were compared against WHRM. The rate of change in glucose levels, as recorded by CGM, resulting from exercise was compared between exercise events documented with the app and recorded by the WHRM. Results Twelve participants generated 277 exercise events. Tracking with the app aligned well with WHRM with respect to frequency, 3.0 (2.1) and 2.5 (1.8) days per week, respectively (p = 0.60). Duration had very high agreement, the mean duration from the app was 65.6 (55.2) and 64.8 (54.9) minutes from WHRM (p = 0.45). Intensity had a low concordance between the data sources (Cohen's kappa = 0.2). The mean rate of change of glucose during exercise was –0.27 mg/(dL*min) and was not significantly different between data sources or intensity (p = 0.21). Conclusion We collated and analyzed data from three heterogeneous sources from free-living participants. Patients' perceived intensity of exercise can serve as a surrogate for exercise tracked by a WHRM when considering the glycemic impact of exercise on self-care regimens.
Insulin Pumping Patches: Emerging Insulin Delivery Systems
Thompson, Bithika , Cook, Curtiss B.

Journal of Diabetes Science and Technology | November 23, 2018 | Volume: 13 | Issue: 1 | Pages: 8-10

10.1177/1932296818814541 Get It

In this special section of JDST, patch-pump delivery systems (“patch pumps”) are discussed. Patch pumps are novel insulin delivery systems that have emerged on the market; offering flexible insulin delivery options. These systems offer several advantages over conventional insulin pump delivery systems and are gaining popularity. Patch pumps are free of tubing, small, and lightweight. In this special section, the authors discuss both the simple and complex patch pumps currently available on the US market as well as those that are currently under development. Current technologies used to operate these pumps are discussed in detail, and potential promising technologies are presented. Available data on patient preferences, clinical trial data, and the future of patch pumps are discussed.
Withholding Perioperative Steroids in Patients Undergoing Transsphenoidal Resection for Pituitary Disease: Randomized Prospective Clinical Trial to Assess Safety
Sterl, Karin, Thompson, Bithika , Goss, Charles W. , Dacey, Ralph G. , Rich, Keith M. , Zipfel, Gregory J. , Silverstein, Julie , Chicoine, Michael , Kim, Albert H.

Neurosurgery | September 19, 2018 | Volume: 85 | Issue: 2 | Pages: E226-E232

10.1093/neuros/nyy479 Get It

Abstract BACKGROUND Perioperative steroid protocols for patients undergoing transsphenoidal surgery (TSS) for pituitary pathology vary by institution. OBJECTIVE To assess the safety of withholding glucocorticoids in patients undergoing TSS. METHODS Patients with an intact hypothalamic-pituitary-adrenal (HPA) axis undergoing TSS for a pituitary tumor at the same academic institution between 2012 and 2015 were randomized to either receive 100 mg of intravenous hydrocortisone followed by 0.5 mg of intravenous dexamethasone every 6 h for 4 doses (STER, n = 23) or to undergo surgery without steroids (NOSTER, n = 20). Postoperative cortisol levels were then used to determine the need for glucocorticoids after surgery. Data regarding postoperative cortisol levels, hospital stay length, and complications were collected. RESULTS Mean postoperative 8 am cortisol levels were higher in the NOSTER group compared to the STER group (745 ± 359 nmol/L and 386 ± 193 nmol/L, respectively, P = .001) and more patients were discharged on glucocorticoids in the STER group (42% vs 12%, P = .07). There was no difference in the incidence of postoperative complications, including hyperglycemia, diabetes insipidus, or permanent adrenal insufficiency. Permanent adrenal insufficiency occurred in 8% of patients. CONCLUSION Perioperative steroids can be safely withheld in patients with an intact HPA axis undergoing TSS. Although administration of perioperative glucocorticoids does not appear to increase the risk of complications, it may interfere with assessment of the HPA axis after surgery.
Do Smartphone Applications Hold the Secret to Reducing Hypoglycemia in Type 1 Diabetes?
Thompson, Bithika

Journal of Diabetes Science and Technology | September 12, 2018 | Volume: 12 | Issue: 6 | Pages: 1200-1202

10.1177/1932296818799363 Get It

In this article in JDST, Feuerstein-Simon and colleagues examine use of a smartphone app in improving hypoglycemia awareness in type 1 diabetes (T1D). They conclude that their smartphone app, HypoMap™, has the potential to increase hypoglycemia awareness and reduce time spent with hypoglycemia in a cohort of long-standing patients with type 1 diabetes. The underlying assumption is that if patients can identify the precipitating cause, they can recognize symptoms better and potentially change behavior to prevent future hypoglycemic events. Potential limitations of this intervention include technical issues, patient burden from data entry with use of an app, and concern that this type of intervention may not be sustainable over time. While results of this pilot study suggest HypoMap may be an effective intervention in preventing hypoglycemia, further studies of increased sample size are needed to confirm these findings.
Design and Testing of a Smartphone Application for Real-Time Self-Tracking Diabetes Self-Management Behaviors
Groat, Danielle , Soni, Hiral , Thompson, Bithika , Cook, Curtiss B. , Grando, Adela , Kaufman, David Ross

Applied Clinical Informatics | June 20, 2018 | Volume: 09 | Issue: 02 | Pages: 440-449

10.1055/s-0038-1660438 Get It

Background Type 1 diabetes (T1D) care requires multiple daily self-management behaviors (SMBs). Preliminary studies on SMBs rely mainly on self-reported survey and interview data. There is little information on adult T1D SMBs, along with corresponding compensation techniques (CTs), gathered in real-time. Objective The article aims to use a patient-centered approach to design iDECIDE, a smartphone application that gathers daily diabetes SMBs and CTs related to meal and alcohol intake and exercise in real-time, and contrast patients' actual behaviors against those self-reported with the app. Methods Two usability studies were used to improve iDECIDE's functionality. These were followed by a 30-day pilot test of the redesigned app. A survey designed to capture diabetes SMBs and CTs was administered prior to the 30-day pilot test. Survey results were compared against iDECIDE logs. Results Usability studies revealed that participants desired advanced features for self-tracking meals and alcohol intake. Thirteen participants recorded over 1,200 CTs for carbohydrates during the 30-day study. Participants also recorded 76 alcohol and 166 exercise CTs. Comparisons of survey responses and iDECIDE logs showed mean% (standard deviation) concordance of 77% (25) for SMBs related to meals, where concordance of 100% indicates a perfect match. There was low concordance of 35% (35) and 46% (41) for alcohol and exercise events, respectively. Conclusion The high variability found in SMBs and CTs highlights the need for real-time diabetes self-tracking mechanisms to better understand SMBs and CTs. Future work will use the developed app to collect SMBs and CTs and identify patient-specific diabetes adherence barriers that could be addressed with individualized education interventions.
Consensus Statement on Use of Continuous Subcutaneous Insulin Infusion Therapy in the Hospital
Thompson, Bithika , Klonoff, David C. , Cook, Curtiss B. , Korytkowski, Mary T. , Klonoff, David C.

Journal of Diabetes Science and Technology | April 21, 2018 | Volume: 12 | Issue: 4 | Pages: 880-889

10.1177/1932296818769933 Get It

In May 2017, the Diabetes Technology Society convened a panel of US experts on inpatient diabetes management to discuss the current and potential role of continuous subcutaneous insulin infusion (CSII) therapy in the hospital. The panel (1) discussed evidence for current use of CSII in the hospital, (2) recommended contraindications for use in the hospital, and (3) recommended guidelines to maximize chances for safe use of CSII in the hospital. Panel members agreed that larger, prospective, randomized studies are needed to evaluate safety and efficacy of CSII use in the hospital. As CSII technology becomes more complex and its use increases, it is imperative that institutional protocols be in place to ensure safe use of this technology and safe transitions across care areas. Providers need to be cognizant that not all patients currently using CSII as an outpatient are appropriate candidates for continued use in the hospital. This consensus statement provides guidelines for practitioners who may encounter patients using this technology in the inpatient setting.
How is the Weather? Forecasting Inpatient Glycemic Control
Saulnier, George E., Castro, Janna C. , Thompson, Bithika , Cook, Curtiss B. , Thompson, Bithika M

Future Science OA | September 11, 2017 | Volume: 3 | Issue: 4 | Pages: No page available

10.4155/fsoa-2017-0066 Get It

Self-Reported Compensation Techniques for Carbohydrate, Exercise, and Alcohol Behaviors in Patients With Type 1 Diabetes on Insulin Pump Therapy
Groat, Danielle , Soni, Hiral , Thompson, Bithika , Grando, Maria Adela, Cook, Curtiss B. , Grando, Adela

Journal of Diabetes Science and Technology | July 11, 2017 | Volume: 12 | Issue: 2 | Pages: 412-414

10.1177/1932296817718848 Get It

Studies have found variability in self-care behaviors in patients with type 1 diabetes, particularly when incorporating exercise and alcohol consumption. The objective of this study was to provide results from a survey to understand (1) insulin pump behaviors, (2) reported self-management behaviors for exercise and alcohol, and (3) perceptions of the effects of exercise and alcohol on blood glucose (BG) control. Fourteen participants from an outpatient endocrinology practice were recruited and administered an electronic survey. Compensation techniques for exercise and alcohol, along with reasons for employing the techniques were identified. Also identified were factors that participants said affected BG control with regard to exercise and alcohol. These results confirm the considerable inconsistency patients have about incorporating exercise and alcohol into decisions about self-management behaviors.