Back to Authors

Mills, John R.

https://orcid.org/0000-0003-1025-4760

Mayo Clinic

Mayo Clinic

Citations 99

72: Exploring Associations Between Genotype and Serology in Celiac Disease
Mills, John R. , Katzman, Brooke M. , Ettore, Michael, Snyder, Melissa R., Murray, Joseph A. , Gandhi, Manish J. , Snyder, Melissa R.

American Journal of Clinical Pathology | February 3, 2017 | Volume: 143 | Issue: suppl_1 | Pages: A042-A042

10.1093/ajcp/143.suppl1.043 Get It

Hereditary Lysozyme Amyloidosis Variant p.Leu102Ser Associates with Unique Phenotype
Nasr, Samih H. , Dasari, Surendra , Mills, John R. , Theis, Jason D. , Zimmermann, Michael T. , Vrana, Julie A., Lester, Steven J., McLaughlin, Brooke M. , Gillespie, Robert L. , Highsmith, W. Edward, Kurtin, Paul J. , Fonseca, Rafaël , Lee, John J. , Dispenzieri, Angela , Zimmermann, Michael T

Journal of the American Society of Nephrology | January 3, 2017 | Volume: 28 | Issue: 2 | Pages: 431-438

10.1681/asn.2016090951 Get It

Lysozyme amyloidosis (ALys) is a rare form of hereditary amyloidosis that typically manifests with renal impairment, gastrointestinal (GI) symptoms, and sicca syndrome, whereas cardiac involvement is exceedingly rare and neuropathy has not been reported. Here, we describe a 40-year-old man with renal impairment, cardiac and GI symptoms, and peripheral neuropathy. Renal biopsy specimen analysis revealed amyloidosis with extensive involvement of glomeruli, vessels, and medulla. Amyloid was also detected in the GI tract. Echocardiographic and electrocardiographic findings were consistent with cardiac involvement. Proteomic analysis of Congo red–positive renal and GI amyloid deposits detected abundant lysozyme C protein. DNA sequencing of the lysozyme gene in the patient and his mother detected a heterozygous c.305T>C alteration in exon 3, which causes a leucine to serine substitution at codon 102 (Human Genome Variation Society nomenclature: p.Leu102Ser; legacy designation: L84S). We also detected the mutant peptide in the proband’s renal and GI amyloid deposits. PolyPhen analysis predicted that the mutation damages the encoded protein. Molecular dynamics simulations suggested that the pathogenesis of ALys p.Leu102Ser is mediated by shifting the position of the central β -hairpin coordinated with an antiparallel motion of the C-terminal helix, which may alter the native-state structural ensemble of the molecule, leading to aggregation-prone intermediates.
Comprehensive Assessment of M-Proteins Using Nanobody Enrichment Coupled to MALDI-TOF Mass Spectrometry
Mills, John R. , Kohlhagen, Mindy , Dasari, Surendra , Vanderboom, Patrick M. , Kyle, Robert A. , Katzmann, Jerry A., Barnidge, David R. , Dispenzieri, Angela , Murray, David , Willrich, Maria Alice V. , Dispenzieri, Angela

Clinical Chemistry | August 18, 2016 | Volume: 62 | Issue: 10 | Pages: 1334-1344

10.1373/clinchem.2015.253740 Get It

Abstract BACKGROUND Electrophoretic separation of serum and urine proteins has played a central role in diagnosing and monitoring plasma cell disorders. Despite limitations in resolution and analytical sensitivity, plus the necessity for adjunct methods, protein gel electrophoresis and immunofixation electrophoresis (IFE) remain front-line tests. METHODS We developed a MALDI mass spectrometry–based assay that was simple to perform, automatable, analytically sensitive, and applicable to analyzing the wide variety of monoclonal proteins (M-proteins) encountered clinically. This assay, called MASS-FIX, used the unique molecular mass signatures of the different Ig isotypes in combination with nanobody immunoenrichment to generate information-rich mass spectra from which M-proteins could be identified, isotyped, and quantified. The performance of MASS-FIX was compared to current gel-based electrophoresis assays. RESULTS MASS-FIX detected all M-proteins that were detectable by urine or serum protein electrophoresis. In serial dilution studies, MASS-FIX was more analytically sensitive than IFE. For patient samples, MASS-FIX provided the same primary isotype information for 98% of serum M-proteins (n = 152) and 95% of urine M-proteins (n = 55). MASS-FIX accurately quantified M-protein to <1 g/dL, with reduced bias as compared to protein electrophoresis. Intraassay and interassay CVs were <20% across all samples having M-protein concentrations >0.045 g/dL, with the ability to detect M-proteins <0.01 g/dL. In addition, MASS-FIX could simultaneously measure κ:λ light chain ratios for IgG, IgA, and IgM. Retrospective serial monitoring of patients with myeloma posttreatment demonstrated that MASS-FIX provided equivalent quantitative information to either protein electrophoresis or the Hevylite™ assay. CONCLUSIONS MASS-FIX can advance how plasma cell disorders are screened, diagnosed, and monitored.
Screening Method for M-Proteins in Serum Using Nanobody Enrichment Coupled to MALDI-TOF Mass Spectrometry
Kohlhagen, Mindy , Barnidge, David R. , Mills, John R. , Stoner, Joshua, Gurtner, Kari M., Liptac, Andrea M, Lofgren, Denise I, Vanderboom, Patrick M. , Dispenzieri, Angela , Katzmann, Jerry A., Snyder, Melissa R, Murray, David , Willrich, Maria Alice V. , Snyder, Melissa R, Dispenzieri, Angela

Clinical Chemistry | August 12, 2016 | Volume: 62 | Issue: 10 | Pages: 1345-1352

10.1373/clinchem.2015.253781 Get It

Abstract BACKGROUND Current recommendations for screening for monoclonal gammopathies include serum protein electrophoresis (PEL), imunofixation electrophoresis (IFE), and free light chain (FLC) ratios to identify or rule out an M-protein. The aim of this study was to examine the feasibility of an assay based on immunoenrichment and MALDI-TOF-MS (MASS-SCREEN) to qualitatively screen for M-proteins. METHODS Serum from 556 patients previously screened for M-proteins by PEL and IFE were immunopurified using a κ/λ-specific nanobody bead mixture. Following purification, light chains (LC) were released from their heavy chains by reduction. MALDI-TOF analysis was performed and the mass-to-charge LC distributions were visually examined for the presence of an M-protein by both unblinded and blinded analysts. RESULTS In unblinded analysis, MASS-SCREEN detected 100% of the PEL-positive samples with an analytical sensitivity and specificity of 96% and 81% using IFE positivity as the standard. In a blinded analysis using 6 different laboratory personnel, consensus was reached in 92% of the samples. Overall analytical sensitivity and specificity were reduced to 92% and 80%, respectively. FLC ratios were found to be abnormal in 28% of MASS-SCREEN–negative samples, suggesting FLC measurements need to be considered in screening. CONCLUSIONS MASS-SCREEN could replace PEL in a panel that would include FLC measurements. Further studies and method development should be performed to validate the clinical sensitivity and specificity and to determine if this panel will suffice as a general screen for monoclonal proteins.
Using Mass Spectrometry to Quantify Rituximab and Perform Individualized Immunoglobulin Phenotyping in ANCA-Associated Vasculitis
Mills, John R. , Dasari, Surendra , Ladwig, Paula M. , Hummel, Amber M., Cheu, Melissa , Murray, David , Snyder, Melissa R., Hoffman, Gary S., Kallenberg, Cees G. M., Langford, Carol A. , Seo, Philip , Clair, E. William St. , Stone, John H., Barnidge, David R. , Snyder, M , Cornec, Divi, Murray, David L., Willrich, Maria A, Cornec, Divi , Willrich, Maria Alice V. , Snyder, Melissa R., Merkel, Peter A. , Monach, Paul A. , Spiera, Robert , Specks, Ulrich , Snyder, Michael

Analytical Chemistry | May 26, 2016 | Volume: 88 | Issue: 12 | Pages: 6317-6325

10.1021/acs.analchem.6b00544 Get It

Abstract Therapeutic monoclonal immunoglobulins (mAbs) are used to treat patients with a wide range of disorders including autoimmune diseases. As pharmaceutical companies bring more fully humanized therapeutic mAb drugs to the healthcare market analytical platforms that perform therapeutic drug monitoring (TDM) without relying on mAb specific reagents will be needed. In this study we demonstrate that liquid-chromatography?mass spectrometry (LC?MS) can be used to perform TDM of mAbs in the same manner as smaller nonbiologic drugs. The assay uses commercially available reagents combined with heavy and light chain disulfide bond reduction followed by light chain analysis by microflow-LC?electrospray ionization-quadrupole-time-of-flight mass spectrometry (ESI-Q-TOF MS). Quantification is performed using the peak areas from multiply charged mAb light chain ions using an in-house developed software package developed for TDM of mAbs. The data presented here demonstrate the ability of an LC?MS assay to quantify a therapeutic mAb in a large cohort of patients in a clinical trial. The ability to quantify any mAb in serum via the reduced light chain without the need for reagents specific for each mAb demonstrates the unique capabilities of LC?MS. This fact, coupled with the ability to phenotype a patient?s polyclonal repertoire in the same analysis further shows the potential of this approach to mAb analysis.
Clonotypic Light Chain Peptides Identified for Monitoring Minimal Residual Disease in Multiple Myeloma without Bone Marrow Aspiration
Bergen, H. Robert, Dasari, Surendra , Dispenzieri, Angela , Mills, John R. , Ramı́rez-Alvarado, Marina , Tschumper, Renee C. , Jelinek, Diane F., Barnidge, David R. , Murray, David , Dispenzieri, Angela , Ramirez-Alvarado, Marina

Clinical Chemistry | October 1, 2015 | Volume: 62 | Issue: 1 | Pages: 243-251

10.1373/clinchem.2015.242651 Get It

Abstract BACKGROUND Analytically sensitive techniques for measuring minimal residual disease (MRD) in multiple myeloma (MM) currently require invasive and costly bone marrow aspiration. These methods include immunohistochemistry (IHC), flow cytometry, quantitative PCR, and next-generation sequencing. An ideal MM MRD test would be a serum-based test sensitive enough to detect low concentrations of Ig secreted from multifocal lesions. METHODS Patient serum with abundant M-protein before treatment was separated on a 1-dimensional SDS-PAGE gel, and the Ig light-chain (LC) band was excised, trypsin digested, and analyzed on a Q Exactive mass spectrometer by LC-MS/MS. We used the peptide's abundance and sequence to identify tryptic peptides that mapped to complementary determining regions of Ig LCs. The clonotypic target tryptic peptides were used to monitor MRD in subsequent serum samples with prior affinity enrichment. RESULTS Sixty-two patients were tested, 20 with no detectable disease by IHC and 42 with no detectable disease by 6-color flow cytometry. A target peptide that could be monitored was identified in 57 patients (91%). Of these 57, detectable disease by LC-MS/MS was found in 52 (91%). CONCLUSIONS The ability to use LC-MS/MS to measure disease in patients who are negative by bone marrow–based methodologies indicates that a serum-based approach has more analytical sensitivity and may be useful for measuring deeper responses to MM treatment. The method requires no bone marrow aspiration.
Fluctuating Serum Aspartate Aminotransferase Activity in a Complicated Pregnancy
Mills, John R. , Greene, Dina N. , Bainton, James, Lorey, Thomas , Baumann, N, Baumann, Nikola A, Greene, Dina

Clinical Chemistry | September 28, 2015 | Volume: 61 | Issue: 10 | Pages: 1241-1244

10.1373/clinchem.2014.228247 Get It

The Perils of Deprofessionalizing Laboratory Test Ordering: Are We Headed Down a Costly Path?
Mills, John R. , Katzman, Brooke M. , Baumann, N

Clinical Chemistry | August 28, 2015 | Volume: 61 | Issue: 9 | Pages: 1216-1217

10.1373/clinchem.2015.242222 Get It

To Monitor Dabigatran or Not: A Matter of Patient Safety
Ketha, Hemamalini , Mills, John R.

Clinical Chemistry | February 5, 2015 | Volume: 61 | Issue: 5 | Pages: 691-693

10.1373/clinchem.2014.232207 Get It