Back to Authors

Willrich, Maria A

Mayo Clinic

Department of Laboratory Medicine and Pathology, Mayo Clinic , Rochester, Minnesota 55905, United States.

Citations 2

Limitations of Free Light Chain Assays caused by the Matrix Effect
Logsdon, Nicole M, Hayes, Jennifer, Rais, Rehan , Gronowski, Ann M., Willrich, Maria A, Farnsworth, Christopher W , Willrich, Maria Alice V.

The Journal of Applied Laboratory Medicine | January 7, 2020 | Volume: 5 | Issue: 2 | Pages: 311-319

10.1093/jalm/jfz021 Get It

Abstract Background Serum free light chain (FLC) assays are used clinically to measure the concentration of κ and λ FLC in patients with suspected or diagnosed plasma cell proliferative disorders. Previous studies have demonstrated a loss of linearity in low concentration ranges of these assays. We hypothesized that this result could be caused by a matrix effect. Methods Recovery studies were performed for κ and λ FLC in both serum and saline using the Freelite assay (Binding Site) on a Cobas c502 system (Roche). Samples were analyzed either at the recommended dilution or undiluted. Follow-up studies were performed in varying matrices ranging from 0% to 100% saline. Retrospective patient data were analyzed to assess the impact on reported κ FLC, λ FLC, and κ/λ ratio. Results FLC in a serum matrix demonstrated underrecovery relative to samples diluted in saline for both κ and λ FLC. Of 255 patient samples with λ FLC measured undiluted (λ FLC <6.0 mg/L), an unexpected gap was observed in patient results between 2.0 and 6.0 mg/L. In addition, 23 patients measured serially with λ FLC between 2.0 and 6.0 mg/L demonstrated dramatic changes in κ/λ ratio, with no changes in κ FLC, likely because of the matrix effect. Conclusions The κ and λ Freelite assays exhibit a matrix effect when samples are tested undiluted, which has the potential to affect the κ/λ ratio. Consequently, our laboratory has stopped reporting λ FLC <6.0 mg/L.
Using Mass Spectrometry to Quantify Rituximab and Perform Individualized Immunoglobulin Phenotyping in ANCA-Associated Vasculitis
Mills, John R. , Dasari, Surendra , Ladwig, Paula M. , Hummel, Amber M., Cheu, Melissa , Murray, David , Snyder, Melissa R., Hoffman, Gary S., Kallenberg, Cees G. M., Langford, Carol A. , Seo, Philip , Clair, E. William St. , Stone, John H., Barnidge, David R. , Snyder, M , Cornec, Divi, Murray, David L., Willrich, Maria A, Cornec, Divi , Willrich, Maria Alice V. , Snyder, Melissa R., Merkel, Peter A. , Monach, Paul A. , Spiera, Robert , Specks, Ulrich , Snyder, Michael

Analytical Chemistry | May 26, 2016 | Volume: 88 | Issue: 12 | Pages: 6317-6325

10.1021/acs.analchem.6b00544 Get It

Abstract Therapeutic monoclonal immunoglobulins (mAbs) are used to treat patients with a wide range of disorders including autoimmune diseases. As pharmaceutical companies bring more fully humanized therapeutic mAb drugs to the healthcare market analytical platforms that perform therapeutic drug monitoring (TDM) without relying on mAb specific reagents will be needed. In this study we demonstrate that liquid-chromatography?mass spectrometry (LC?MS) can be used to perform TDM of mAbs in the same manner as smaller nonbiologic drugs. The assay uses commercially available reagents combined with heavy and light chain disulfide bond reduction followed by light chain analysis by microflow-LC?electrospray ionization-quadrupole-time-of-flight mass spectrometry (ESI-Q-TOF MS). Quantification is performed using the peak areas from multiply charged mAb light chain ions using an in-house developed software package developed for TDM of mAbs. The data presented here demonstrate the ability of an LC?MS assay to quantify a therapeutic mAb in a large cohort of patients in a clinical trial. The ability to quantify any mAb in serum via the reduced light chain without the need for reagents specific for each mAb demonstrates the unique capabilities of LC?MS. This fact, coupled with the ability to phenotype a patient?s polyclonal repertoire in the same analysis further shows the potential of this approach to mAb analysis.