BACKGROUND Pulmonary transfusion reactions are important complications of blood transfusion, yet differentiating these clinical syndromes is diagnostically challenging. We hypothesized that biologic markers of inflammation could be used in conjunction with clinical predictors to distinguish transfusion‐related acute lung injury (TRALI), transfusion‐associated circulatory overload (TACO), and possible TRALI. STUDY DESIGN AND METHODS In a nested case‐control study performed at the University of California at San Francisco and Mayo Clinic, Rochester, we evaluated clinical data and blood samples drawn before and after transfusion in patients with TRALI (n = 70), possible TRALI (n = 48), TACO (n = 29), and controls (n = 147). Cytokines measured included granulocyte‐macrophage–colony‐stimulating factor, interleukin (IL)‐6, IL‐8, IL‐10, and tumor necrosis factor‐α. Logistic regression and receiver operating characteristics curve analyses were used to determine the accuracy of clinical predictors and laboratory markers in differentiating TACO, TRALI, and possible TRALI. RESULTS Before and after transfusion, IL‐6 and IL‐8 were elevated in patients with TRALI and possible TRALI relative to controls, and IL‐10 was elevated in patients with TACO and possible TRALI relative to that of TRALI and controls. For all pulmonary transfusion reactions, the combination of clinical variables and cytokine measurements displayed optimal diagnostic performance, and the model comparing TACO and TRALI correctly classified 92% of cases relative to expert panel diagnoses. CONCLUSIONS Before transfusion, there is evidence of systemic inflammation in patients who develop TRALI and possible TRALI but not TACO. A predictive model incorporating readily available clinical and cytokine data effectively differentiated transfusion‐related respiratory complications such as TRALI and TACO.
A multicenter study of plasma use in the United States
BackgroundDetailed information regarding plasma use in the United States is needed to identify opportunities for practice improvement and design of clinical trials of plasma therapy.Study Design and MethodsTen US hospitals collected detailed medical information from the electronic health records for 1 year (2010‐2011) for all adult patients transfused with plasma.ResultsA total of 72,167 units of plasma were transfused in 19,596 doses to 9269 patients. The median dose of plasma was 2 units (interquartile range, 2‐4; range 1‐72); 15% of doses were 1 unit, and 45% were 2 units. When adjusted by patient body weight (kg), the median dose was 7.3 mL/kg (interquartile range, 5.5‐12.0). The median pretransfusion international normalized ratio (INR) was 1.9 (25%‐75% interquartile range, 1.6‐2.6). A total of 22.5% of plasma transfusions were given to patients with an INR of less than 1.6 and 48.5% for an INR of 2.0 or more. The median posttransfusion INR was 1.6 (interquartile range, 1.4‐2.0). Only 42% of plasma transfusions resulted in a posttransfusion INR of less than 1.6. Correction of INR increased as the plasma dose increased from 1 to 4 units (p < 0.001). There was no difference in the INR response to different types of plasma. The most common issue locations were general ward (38%) and intensive care unit (ICU; 42%).ConclusionThis large database describing plasma utilization in the United States provides evidence for both inadequate dosing and unnecessary transfusion. Measures to improve plasma transfusion practice and clinical trials should be directed at patients on medical and surgical wards and in the ICU where plasma is most commonly used.