Molecular Biomarkers for the Evaluation of Colorectal Cancer: Guideline Summary From the American Society for Clinical Pathology, College of American Pathologists, Association for Molecular Pathology, and American Society of Clinical Oncology
Abstract Objectives: To develop evidence-based guideline recommendations through a systematic review of the literature to establish standard molecular biomarker testing of colorectal cancer (CRC) tissues to guide epidermal growth factor receptor (EGFR) therapies and conventional chemotherapy regimens. Methods: The American Society for Clinical Pathology, College of American Pathologists, Association for Molecular Pathology, and American Society of Clinical Oncology convened an expert panel to develop an evidence-based guideline to establish standard molecular biomarker testing and guide therapies for patients with CRC. A comprehensive literature search that included more than 4,000 articles was conducted. Results: Twenty-one guideline statements were established. Conclusions: Evidence supports mutational testing for EGFR signaling pathway genes, since they provide clinically actionable information as negative predictors of benefit to anti-EGFR monoclonal antibody therapies for targeted therapy of CRC. Mutations in several of the biomarkers have clear prognostic value. Laboratory approaches to operationalize CRC molecular testing are presented.
Molecular Biomarkers for the Evaluation of Colorectal Cancer: Guideline From the American Society for Clinical Pathology, College of American Pathologists, Association for Molecular Pathology, and American Society of Clinical Oncology
Objectives.— To develop evidence-based guideline recommendations through a systematic review of the literature to establish standard molecular biomarker testing of colorectal cancer (CRC) tissues to guide epidermal growth factor receptor (EGFR) therapies and conventional chemotherapy regimens. Methods.— The American Society for Clinical Pathology, College of American Pathologists, Association for Molecular Pathology, and American Society of Clinical Oncology convened an expert panel to develop an evidence-based guideline to establish standard molecular biomarker testing and guide therapies for patients with CRC. A comprehensive literature search that included more than 4,000 articles was conducted. Results.— Twenty-one guideline statements were established. Conclusions.— Evidence supports mutational testing for EGFR signaling pathway genes, since they provide clinically actionable information as negative predictors of benefit to anti-EGFR monoclonal antibody therapies for targeted therapy of CRC. Mutations in several of the biomarkers have clear prognostic value. Laboratory approaches to operationalize CRC molecular testing are presented.
Interpretive Diagnostic Error Reduction in Surgical Pathology and Cytology: Guideline From the College of American Pathologists Pathology and Laboratory Quality Center and the Association of Directors of Anatomic and Surgical Pathology
Context Additional reviews of diagnostic surgical and cytology cases have been shown to detect diagnostic discrepancies. Objective To develop, through a systematic review of the literature, recommendations for the review of pathology cases to detect or prevent interpretive diagnostic errors. Design The College of American Pathologists Pathology and Laboratory Quality Center in association with the Association of Directors of Anatomic and Surgical Pathology convened an expert panel to develop an evidence-based guideline to help define the role of case reviews in surgical pathology and cytology. A literature search was conducted to gather data on the review of cases in surgical pathology and cytology. Results The panel drafted 5 recommendations, with strong agreement from open comment period participants ranging from 87% to 93%. The recommendations are: (1) anatomic pathologists should develop procedures for the review of selected pathology cases to detect disagreements and potential interpretive errors; (2) anatomic pathologists should perform case reviews in a timely manner to avoid having a negative impact on patient care; (3) anatomic pathologists should have documented case review procedures that are relevant to their practice setting; (4) anatomic pathologists should continuously monitor and document the results of case reviews; and (5) if pathology case reviews show poor agreement within a defined case type, anatomic pathologists should take steps to improve agreement. Conclusions Evidence exists that case reviews detect errors; therefore, the expert panel recommends that anatomic pathologists develop procedures for the review of pathology cases to detect disagreements and potential interpretive errors, in order to improve the quality of patient care.
Verifying Performance Characteristics of Quantitative Analytical Systems: Calibration Verification, Linearity, and Analytical Measurement Range
Context.— Both the regulations in the Clinical Laboratory Improvement Amendments of 1988 (CLIA) and the checklists of the College of American Pathologists (CAP) Laboratory Accreditation Program require clinical laboratories to verify performance characteristics of quantitative test systems. Laboratories must verify performance claims when introducing an unmodified, US Food and Drug Administration–cleared or approved test system, and they must comply with requirements for periodic calibration and calibration verification for existing test systems. They must also periodically verify the analytical measurement range of many quantitative test systems. Objective.— To provide definitions for many of the terms used in these regulations, to describe a set of basic analyses that laboratories may adapt to demonstrate compliance with both CLIA and the CAP Laboratory Accreditation Program checklists for performing calibration verification and for verifying the analytical measurement range of test systems, to review some of the recommended procedures for establishing performance goals, and to provide data illustrating the performance goals used in some of the CAP's calibration verification and linearity surveys. Data Sources.— The CAP's calibration verification and linearity survey programs, the CLIA regulations, the Laboratory Accreditation Program requirements, and published literature were used to meet these objectives. Conclusions.— Calibration verification and linearity and analytical measurement range verification should be performed using suitable materials with assessment of results using well-defined evaluation protocols. We describe the CAP's calibration verification and linearity programs that may be used for these purposes.