Back to Authors

Andrews, James C.

https://orcid.org/0000-0003-1481-2096

Mayo Clinic

Mayo Clinic

Citations 26

Lumbar Artery Pseudoaneurysm Caused by a Gunther Tulip Inferior Vena Cava Filter
McEachen, J.C., Stockland, Andrew H., Wennberg, Paul W. , Shepherd, Roger F.J., Shields, Raymond C., Andrews, James C. , Skeik, Nedaa

Vascular and Endovascular Surgery | January 19, 2012 | Volume: 45 | Issue: 8 | Pages: 756-760

10.1177/1538574411419373 Get It

Inferior vena cava (IVC) filters are widely used to decrease the risk of pulmonary embolism in patients with contraindications to anticoagulation. Complications include local hematoma, access site deep venous thrombosis (DVT), filter migration and embolization, leg penetration through the IVC wall, IVC occlusion, and filter fracture with embolization. Other rare complications include leg penetration into adjacent organs including duodenum and ureter. Lumbar artery pseudoaneurysms are rare and may be spontaneous, iatrogenic, or traumatic. To date, there have been 3 case reports of lumbar artery pseudoaneurysms caused by IVC filters. We present an additional case of a lumbar artery pseudoaneurysm caused by a Gunther Tulip IVC filter treated successfully with selective embolization.
Secular Trends in the Presentation and Management of Functioning Insulinoma at the Mayo Clinic, 1987–2007
Placzkowski, Kimberly A., Thompson, Geoffrey B. , Grant, Clive S., Reading, Carl C., Charboneau, J. William, Andrews, James C. , Lloyd, Ricardo V., Service, F. John, Vella, Adrian

The Journal of Clinical Endocrinology & Metabolism | January 13, 2009 | Volume: 94 | Issue: 4 | Pages: 1069-1073

10.1210/jc.2008-2031 Get It

Aorto Uni-iliac Modification of a Bifurcated Stent Graft for Endovascular Aneurysm Repair: Expanding the Versatility of a Modular Device
Sampaio, Sérgio , Panneton, Jean M. , Brink, Jeromy, Andrews, James C. , McKusick, Michael C., Gloviczki, Péter , Gloviczki, Péter

Vascular and Endovascular Surgery | June 21, 2007 | Volume: 40 | Issue: 2 | Pages: 103-107

10.1177/153857440604000203 Get It

As endografting technology advances, anatomical constraints limiting access and deployment have become less of a burden. While unsuitable candidates for endografting exist, these patients are becoming less frequent. To broaden the applicability of endovascular abdominal aortic aneurysm repair (EVAR), we have modified the bifurcated AneuRx™ device into a unilimb modular prosthesis, by placing an aortic extender cuff across the flow divider, thus excluding its contralateral limb. This technique was used with success in 3 groups of patients: with occlusion of 1 iliac artery, with a nontraversable iliac stenosis, or with a small calcific aortic bifurcation. In these patients, anatomy can make it difficult, if not impossible, to place a bifurcated stent graft. Whether as a planned preoperative procedure or as a ‘bail-out’ maneuver, this procedure has been successful in avoiding open surgical conversion.
Most Patients with Abdominal Aortic Aneurysm Are Not Suitable for Endovascular Repair Using Currently Approved Bifurcated Stent-Grafts
Elkouri, Stéphane , Martelli, Eugenio , Gloviczki, Péter , McKusick, Michael A., Panneton, Jean M. , Andrews, James C. , Noel, Audra A., Bower, Thomas C., Sullivan, Timothy M. , Rowland, Charles M. , Cherry, Kenneth J., Hoskin, Tanya L. , Gloviczki, Péter

Vascular and Endovascular Surgery | March 31, 2006 | Volume: 38 | Issue: 5 | Pages: 401-412

10.1177/153857440403800502 Get It

Strict morphologic criteria must be used for patient selection to achieve durable success with endovascular aortic aneurysm repair (EVAR). The goal of this study was to assess morphologic suitability (MS) of abdominal aortic aneurysms (AAAs) for 2 currently approved bifurcated stent grafts and identify reasons for exclusion from EVAR. The authors reviewed the electronic charts of 1,795 consecutive patients who were diagnosed as having AAA between January 1999 and July 2001 at their institution. Three hundred and twenty patients had an AAA with a diameter of =5.0 cm, measured on computed tomography (CT). The records of 301 patients, 254 men, 47 women, with a mean age of 74 years were available for review, and these patients constituted the study cohort. Criteria used for MS included a proximal neck length =15 mm; neck diameter between 18 and 26 mm; neck angulation =60°; common or external iliac artery (CIA or EIA) diameters of 7–16 mm and 8–13 mm, respectively, for AneuRx (Medtronic Ave, Santa Rosa, CA) and Ancure (Guidant Cardiac and Vascular Division, Menlo Park, CA) bifurcated grafts. AAAs were suitable for AneuRx device in 14% of patients (43 of 301; 95% CI = 11–19%) and for Ancure in 5% (16 of 301; 95% CI = 3.1–9%). The main reason for exclusion was an inadequate proximal aortic neck (73%). The neck was too short in 49.5%, too wide in 64% and badly angulated in 12% of the patients. Iliac artery morphology precluded EVAR with AneuRx and Ancure devices in 52% and 80%. Both CIAs were too wide for EVAR in 43% and 77%, respectively. When iliac artery diameter =20 mm was accepted, iliac suitability for AneuRx increased from 49% to 70% and overall suitability increased from 14% to 20%. When more permissive criteria were used for MS (neck length =10 mm, neck diameter =30 mm, CIA =20), 39% of patients became candidates for EVAR. More than three fourths of the patients with an AAA =5.0 cm in size, seen in a tertiary referral center, are morphologically not suitable for EVAR using 2 currently approved bifurcated endografts. The main reasons for exclusion are a short or wide proximal aortic neck. Considerable changes in size of the devices and in proximal attachment techniques have to occur before most AAAs will be suitable for EVAR.
Non-insulinoma pancreatogenous hypoglycaemia syndrome
Service, F J, Thompson, Geoffrey B. , Natt, Neena, Grant, Clive S., Heerden, Jon A. van, Andrews, James C. , Lloyd, Ricardo V.

Journal of British Surgery | March 11, 2003 | Volume: 87 | Issue: 9 | Pages: 1274-1275

10.1046/j.1365-2168.2000.01601-44.x Get It

Abstract Background The authors have reported a newly recognized hypoglyacemic disorder, non-insulinoma pancreatogenous hypoglycaemia syndrome (NIPHS), which is characterized by postprandial hyperinsulinaemic hypoglycaemia, negative 72-h fast, negative transabdominal and intraoperative ultrasonography, spiral computed tomography and coeliac axis angiography, positive selective arterial calcium stimulation test (SACST), absence of insulinoma but presence of islet hypertrophy and nesidioblastosis, and relief of symptoms from gradient-guided partial pancreatectomy. Experience with the next five patients with this disorder (6–10; 1998–1999) compared with the original five (1–5; 1996–1998) is reported. Results Wide age range, male predominance, postprandial occurrence of symptoms, negative radiological localization, nesidioblastosis/islet hypertrophy, but no insulinoma characterized all ten cases. Response to SACST indicated widespread islet hyperfunction in patients 1 and 5; limitation to distribution of the SPA and GDA in patients 3, 4, 6 and 8, to distribution of the SPA in patients 2, 7 and 9, and to distribution of the SMA in patient 10. Except for patient 5, pancreatic resection to the left of the SMV was performed when only the SPA was positive on the SACST. Patients 5 and 8 have had recurrence of symptoms; they resolved within 3 months for patient 5. Conclusion NIPHS can usually be treated successfully with gradient-guided partial pancreatectomy.
The kidney is an important site for in vivo phenylalanine-to-tyrosine conversion in adult humans: A metabolic role of the kidney
Møller, Niels , Meek, Shon E., Bigelow, Maureen L., Andrews, James C. , Nair, K. Sreekumaran , Møller, Niels

Proceedings of the National Academy of Sciences | July 26, 2002 | Volume: 97 | Issue: 3 | Pages: 1242-1246

10.1073/pnas.97.3.1242 Get It

Synthesis of Tyr in the human body occurs by hydroxylation of the indispensable amino acid Phe. Until now, it was believed that in humans, this process was restricted to the liver, but we provide compelling evidence of production of Tyr from Phe in the kidney. To determine whether the human kidney produces Tyr, we measured Tyr balance, the Tyr appearance rate, and the Phe-to-Tyr conversion in 12 healthy human subjects by using [ 15 N]Phe and [ 2 H 4 ]Tyr as tracers. Renal plasma flow was measured by using paraaminohippurate, and sampling from the femoral artery and renal veins was performed. The results were compared with those obtained in 12 control subjects undergoing hepatic vein catheterization and infusion of identical tracers. In all 12 subjects, there was a net uptake of Phe by the kidney (2.2 ± 1.2 μmol/min), whereas Tyr was released (5.3 ± 1.5 μmol/min). In contrast, there was a net uptake of both Phe (9.5 ± 1.2 μmol/min) and Tyr (14.3 ± 1.3 μmol/min) by the splanchnic bed. Phe conversion to Tyr occurred at a rate of 5.2 ± 1.2 μmol/min in kidney and 3.0 ± 0.7 μmol/min in the splanchnic bed. The kidney contributed a substantial amount of Tyr to the systemic circulation where the splanchnic bed was a net remover of Tyr. Our results demonstrate that the kidney is the major donor of Tyr to the systemic circulation by its conversion of Phe to Tyr. This observation may have important clinical implications for patients with both renal and hepatic disease, who may be at risk of Phe overloading and Tyr deficiency, and it should be considered when parenteral or enteral nutrients are administered rich in Phe and low in Tyr.