Background: Familial transthyretin amyloidosis is a disease caused by misfolded transthyretin aggregates that can impair multiple organ systems. Liver transplantation is the first-line treatment for familial transthyretin amyloidosis. Research Question: Our objective is to study outcomes and survival among patients with familial transthyretin amyloidosis after transplantation. Design: All patients undergoing orthotopic liver transplant for familial transthyretin amyloidosis at Mayo Clinic between 1997 and 2012 were reviewed. Baseline clinical characteristics, organs transplanted, and posttransplant clinical course were assessed. Results: Of the 40 patients, 7 patients had the V30M mutation and 33 had other mutations. Nineteen patients received liver only, 19 liver and heart, and 2 combined liver, heart, and kidney transplants. The 5-year overall survival was 85% for those receiving multiple organ transplant and 52% for those receiving liver transplant only ( P = .057). There was no difference in overall survival based on mutation (V30M vs other mutations), but survival was confounded by varied disease involvement and organs transplanted. Those who had early death (≤24 months from liver transplant) had a higher incidence of baseline peripheral neuropathy, autonomic neuropathy, lower modified BMI, and higher alkaline phosphatase. Discussion: Outcomes of orthotopic liver transplant in familial transthyretin amyloidosis are variable due to heterogeneity in mutations and patient status at the time of transplant. Familial transthyretin amyloidosis can progress, despite liver transplantation. Patients receiving combined liver, heart/kidney transplant demonstrated improved survival compared to liver transplant alone.
Pulmonary Pressure Assessment with the Total Artificial Heart
Reversal of pulmonary hypertension has been observed in patients during a bridge to transplant with a left ventricular assist device. Total artificial heart (TAH) implant prevents subsequent right heart catheterization. Consequently, controversy exists over whether the prosthetic right ventricle improves or exacerbates pulmonary hypertension. A pulmonary artery (PA) pressure monitor was placed in two patients undergoing TAH implant, as a bridge to transplant. One patient had pulmonary hypertension at implant; the other had normal pulmonary pressures. Daily measurements were taken of systolic, diastolic, and mean PA pressures throughout support. Patient 1 received successful transplant after TAH support of 91 days. Systolic/diastolic (mean) PA pressures steadily decreased from 55/39 (28) mm Hg at implant to 29/18 (7) mm Hg currently. Patient 2 received support for 101 days before death due to abdominal ischemic complications. Pulmonary arterial pressures stayed consistent throughout this period, from 26/17 (20) mm Hg at implant to 23/13 (17) mm Hg at the time of death. These findings suggest that an implantable PA pressure monitor may be useful in optimizing hemodynamics and planning appropriate timing of transplant with TAH support.
Early Gains in Renal Function Following Implantation of HeartMate II Left Ventricular Assist Devices May Not Persist to One Year
Renal function improves early after left ventricular assist device (LVAD) implantation but later decline has been observed. We sought to determine the occurrence and evaluate possible causes for this decline. In 62 consecutive patients with HeartMateII LVAD with available calculated glomerular filtration rate (GFR, ml/min/1.73 m2) 1 year after implant, GFR was assessed repeatedly and possible predictors for decline from 3 to 12 months were investigated. Post-mortem renal specimens for patients supported with an LVAD were evaluated. GFR 54.5 ± 19.5 at admission increased to 66.4 ± 22.3 preoperatively and to 79.2 ± 30.1 ~1 month after implantation. Subsequently at ~3 months GFR declined to 74.7 ± 25.4, at ~6 months to 68.8 ± 23.1, and ~1 year after implant to 63.9 ± 17.7. Glomerular filtration rate at 1 year was significantly lower (p < 0.0001, p < 0.0001, p = 0.005) than GFR 1, 3, and 6 months after implant. Early rise in GFR after surgery was not associated with late decline. Shorter bypass time (β = −0.09, p = 0.048) and higher albumin 3 months after LVAD (β = 14.4, p = 0.025) were significantly associated with less later decline in GFR. Arteriosclerosis was identified in autopsy renal specimens. In conclusion, early gains in renal function after LVAD implant are not sustained in many patients. Patient, device, and operative factors may influence long-term renal function in these patients.
Left Internal Mammary Artery Versus Coronary Stents: Impact on Downstream Coronary Stenoses and Conduit Patency
Background The study compared downstream coronary and conduit disease progression in the left anterior descending coronary artery treated with coronary artery bypass grafting using the left internal mammary artery ( LIMA ) versus percutaneous coronary intervention with bare metal stent ( BMS ) or drug eluting stent ( DES ). Methods and Results A total of 12 301 consecutive patients underwent isolated primary coronary revascularization, of which 2386 met our inclusion criteria (Percutaneous coronary intervention, n=1450; coronary artery bypass grafting, n=936). Propensity score analysis matched 628 patients, of which 468 were treated to the left anterior descending with coronary artery bypass grafting with LIMA (n=314), percutaneous coronary intervention with BMS (n=94), and DES (n=60). Coronary angiograms were analyzed by quantitative coronary angiography ( QCA ; n=433). Cumulative downstream coronary and conduit disease progression were estimated by Kaplan–Meier method and effect of treatment type by Cox proportional hazard models. Patients treated with LIMA had significantly lower risk of downstream coronary disease progression at follow‐up angiogram compared with BMS and DES (hazard ratio [ HR ] [95% CI ], 0.34; [0.20–0.59]; P =0.0002; and HR [95% CI ], 0.39; [0.20–0.79]; P =0.01, respectively). LIMA was associated with a lower risk of conduit disease progression compared to BMS and DES ( HR [95% CI ], 0.18; [0.12–0.28]; P <0.001; and HR [95% CI ], 0.27; [0.16–0.46]; P <0.001, respectively). BMS was associated with higher HR for downstream coronary and conduit disease progression compared with DES , but the difference did not reach statistical significance ( HR [95% CI], 1.13; [0.57–2.36]; P =0.73; and HR [95% CI ], 1.46; [0.88–2.50]; P =0.14, respectively). Conclusions LIMA grafting to left anterior descending is associated with significantly lower risk of downstream coronary and conduit disease progression compared to percutaneous coronary intervention with BMS and DES .
Sex Related Differences in the Risk of Antibody-Mediated Rejection and Subsequent Allograft Vasculopathy Post-Heart Transplantation: A Single-Center Experience
Background Pregnancies may result in antibodies against HLA, a risk factor for antibody-mediated rejection (AMR) and subsequent cardiac allograft vasculopathy (CAV) after heart transplantation (HTx). The aim of this study was to evaluate sex differences in the incidence of AMR events and subsequent risk of CAV among HTx recipients. Methods The study comprised 160 patients (51 [32%] women) who underwent HTx in 2008 to 2014. The cumulative effect of AMR events was calculated by AMR score (sum of myocardial biopsy grading divided by number of biopsies taken during 3 years post-HTx). Results Females had higher levels of anti-HLA I antibodies pre-HTx compared to males which was associated with a history of pregnancies, total number of children and with a higher AMR score at 6 months post-HTx (P < 0.05). Women demonstrated a significant increase in the total incidence of AMR events (27 vs. 7%, P = 0.001) and in AMR scores at 6, 12, 24 and 36 months post-HTx compared to men (P < 0.05). There were no differences in cellular rejection between the groups. A history of AMR events was associated with a significantly increased risk of severe CAV onset (hazard ratio, 7.0; 95% confidence interval, 1.5-31.5; P = 0.012). Conclusions Women are at higher risk for AMR post-HTx which subsequently increases their risk for CAV. Females recipients may benefit from closer surveillance to identify AMR at an earlier stage post-HTx, and targeted immunosuppressive therapy to attenuate the development of CAV.
Postcardiotomy ECMO Support after High-risk Operations in Adult Congenital Heart Disease
AbstractWe performed a retrospective review of outcomes after heart transplantation during long‐term follow‐up of a surgical cohort of 1138 Fontan patients who were followed at the Mayo Clinic. Follow‐up information was obtained from medical records and a clinical questionnaire that was mailed to patients not known to be deceased at the initiation of the study. Forty‐four of 1138 Fontan patients with initial or subsequent evaluation at Mayo had cardiac transplantation between 1988 and 2014 (mean age at transplantation was 23.2 ± 12 yr, median was 19.8 yr; mean interval between Fontan and transplantation was 13.0 ± 7.7 yr, median was 13.1 yr). Two patients had combined organ transplantation (one heart–lung, one heart–liver). Twelve of the 44 (27%) patients had PLE prior to transplantation. There was no difference in post‐bypass Fontan pressures or incidence of late reoperations for AVV repair/replacement between transplanted and non‐transplanted patients. There were 16 (36%) deaths in the transplantation cohort; seven occurred within 30 days of transplantation. Overall one, five, 10, and 15 yr post‐transplantation survival was 80%, 72%, 69%, and 55%, respectively. Although this is a challenging group of patients, intermediate‐term results suggest that cardiac transplantation remains a reasonable option for patients with a failed Fontan circulation.
Robotic Mitral Valve Repair for Simple and Complex Degenerative Disease
Background— Severe primary (degenerative) mitral regurgitation (MR) is repaired with durable results when simple single-scallop disease is addressed. The midterm quality outcomes of minimally invasive repair for complex disease are unknown, however. Methods and Results— From January 2008 to January 2015, 487 patients (56±11 years, 360 men, ejection fraction 65±6%, 98.8% complete follow-up) underwent robotic mitral valve repair for severe nonischemic degenerative MR. Simple pathology was addressed in 289 of 487 (59%) patients, and complex repair (all others) was performed in 198 of 487 (41%). Four patients died during follow-up with a 5-year survival rate 99.5% (99.4% simple; 99.5% complex; hazard ratio, 0.48; 95% confidence interval, 0.05–4.59); and New York Heart Association functional class I/II was documented in 97.9% (477/487). Eight patients had recurrence of moderate-to-severe MR (4 simple, 4 complex), with a 5-year freedom from MR of 94.6% (96.2% simple; 92.7%, complex; P =0.67; hazard ratio, 1.36; 95% confidence interval, 0.34–5.43). Seven patients (2 simple, 5 complex), underwent mitral reoperation, with a 5-year freedom from reoperation of 97.7% (99.1% simple; 95.7% complex; P =0.13; hazard ratio, 3.35; 95% confidence interval, 0.65–17.32). Conclusions— At a large tertiary care referral center, midterm quality outcomes after robotic correction of degenerative MR are excellent, with very high survival, infrequent complications, and a low likelihood of MR recurrence, regardless of mitral valve repair complexity. Awareness of these improvements in outcome is important to inform contemporary decisions regarding high-quality alternatives to conventional and percutaneous mitral repair.
Impact of Surgical Ventricular Reconstruction on Sphericity Index in Patients with Ischaemic Cardiomyopathy: Follow-Up from the STICH Trial
Abstract Aims We sought to evaluate associations between baseline sphericity index (SI) and clinical outcome, and changes in SI after coronary artery bypass graft (CABG) surgery with or without surgical ventricular reconstruction (SVR) in ischaemic cardiomyopathy patients enrolled in the SVR study (Hypothesis 2) of the Surgical Treatment for Ischemic Heart Failure (STICH) trial. Methods and results Among 1000 patients in the STICH SVR study, we evaluated 546 patients (255 randomized to CABG alone and 291 to CABG + SVR) whose baseline SI values were available. SI was not significantly different between treatment groups at baseline. After 4 months, SI had increased in the CABG + SVR group, but was unchanged in the CABG alone group (0.69 ± 0.10 to 0.77 ± 0.12 vs. 0.67 ± 0.07 to 0.66 ± 0.09, respectively; P < 0.001). SI did not significantly change from 4 months to 2 years in either group. Although LV end-systolic volume and EF improved significantly more in the CABG + SVR group compared with CABG alone, the severity of mitral regurgitation significantly improved only in the CABG alone group, and the estimated LV filling pressure (E/A ratio) increased only in the CABG + SVR group. Higher baseline SI was associated with worse survival after surgery (hazard ratio 1.21, 95% confidence interval 1.02 − 1.43; P = 0.026). Survival was not significantly different by treatment strategy. Conclusion Although SVR was designed to improve LV geometry, SI worsened after SVR despite improved LVEF and smaller LV volume. Survival was significantly better in patients with lower SI regardless of treatment strategy.