Back to Authors

Hagler, Donald J.

https://orcid.org/0000-0002-0331-3294

Mayo Clinic

Mayo Clinic

Citations 53

Temporary balloon occlusion of atrial septal defects in suspected or documented left ventricular diastolic dysfunction: Hemodynamic and clinical findings
Miranda, William R. , Hagler, Donald J. , Reeder, Guy S., Warnes, Carole A. , Connolly, Heidi M. , Egbe, Alexander C. , Taggart, Nathaniel W. , Taggart, Nathaniel W

Catheterization and Cardiovascular Interventions | February 12, 2019 | Volume: 93 | Issue: 6 | Pages: 1069-1075

10.1002/ccd.28150 Get It

AbstractObjectiveTo review our experience with balloon testing prior to atrial septal defect (ASD) closure in adults with left ventricular (LV) diastolic dysfunction.BackgroundASD closure in patients with LV diastolic dysfunction may precipitate LV failure. Temporary ASD occlusion has been used in this scenario but data are limited.MethodsRetrospective review of 27 patients age ≥ 50 years undergoing temporary ASD balloon occlusion between 2000 and 2018 for suspected LV diastolic dysfunction or elevated LV end‐diastolic pressure (LVEDP).ResultsMedian age was 72 years (IQR 66.7; 75.2). Atrial fibrillation was seen in 58% of patients, hypertension in 58%, and coronary artery disease in 26%; 52% were females. Median ASD size was 13 mm (10; 18) and Qp/Qs 1.8 (1.6; 2.2). Median LVEDP was 14 mmHg (12; 22); pulmonary artery wedge pressure (PAWP) 12 mmHg (9; 16.5) and left atrial pressure (LAP) 13.5 mmHg (8; 16.3). After a median of 5 min (3; 10) of balloon occlusion, patients with baseline LVEDP ≥15 mmHg had more significant increases in LVEDP (9 [6; 12] vs. 2 mmHg [0.5; 5]; p = 0.03) and LAP/PAWP (10.5 [8.3; 16.3] vs. 1.5 mmHg [−1.5; 3]; p = 0.0003) than those with baseline LVEDP <15 mmHg. None of those with a baseline LVEDP <15 mmHg had a LAP/PAWP >15 mmHg during balloon testing compared to 92% of patients with a baseline LVEDP ≥15 mmHg.ConclusionLVEDP might be used to predict LAP post‐ASD closure. Comorbidities typically associated with LV diastolic dysfunction are common in these patients and should be considered in their management.
Haemodynamic Profiles in Adult Fontan Patients: Associated Haemodynamics and Prognosis
Miranda, William R. , Borlaug, Barry A. , Hagler, Donald J. , Connolly, Heidi M. , Egbe, Alexander C. , Borlaug, Barry A

European Journal of Heart Failure | January 24, 2019 | Volume: 21 | Issue: 6 | Pages: 803-809

10.1002/ejhf.1365 Get It

Abstract Aims The Fontan operation is associated with significant long-term morbidity and mortality, posing challenges in management. No haemodynamic classification has been established to aid management and prognostication of patients with Fontan palliation. Our aim was to assess haemodynamic profiles for Fontan patients and evaluate their relationships to prognosis. Methods and results Eighty-four adult Fontan patients without obstruction or significant valve disease undergoing cardiac catheterization for Fontan-related co-morbidities were divided into four different haemodynamic profiles based on normal/high Fontan pressures (FP) (&lt; 15 or ≥ 15 mmHg) and low/normal cardiac index (CI) (&lt; 2.5 or ≥ 2.5 L/min/m2). Fourteen patients had low CI/high FP (17%), 24 low CI/normal FP (29%), 20 normal CI/high FP (24%), and 26 normal CI/normal FP (31%). Demographic and clinical data were similar among groups except for a trend towards a higher prevalence of cirrhosis in the normal CI/high FP (50%) group. Systemic vascular afterload, assessed by systemic vascular resistance and effective arterial elastance, was higher in patients with low CI/high FP and low CI/normal FP as compared to normal CI profiles. Pulmonary vascular resistance indices were higher in patients with low CI/high FP than all other profiles. The normal CI/high FP haemodynamic profile was an independent predictor of mortality (hazard ratio 4.1, 95% confidence interval 1.2–11.5). Heterotaxy and protein-losing enteropathy were also predictors of mortality on the multivariate model. Conclusion The proposed haemodynamic classification provides prognostic information in adults post-Fontan with patients in the normal CI/high FP profile having worse survival. Whether this classification can guide management in these patients deserves further investigation.
Effect of percutaneous paravalvular leak closure on hemolysis
Panaich, Sidakpal , Maor, Elad , Reddy, Gautam , Raphael, Claire E. , Hagler, Donald J. , Reeder, Guy S., Rihal, Charanjit S. , Eleid, Mackram F. , Panaich, Sidakpal S , Cabalka, Allison, Hagler, Donald J , Eleid, Mackram F , Raphael, Claire , Maor, Elad , Cabalka, Allison K. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | October 3, 2018 | Volume: 93 | Issue: 4 | Pages: 713-719

10.1002/ccd.27917 Get It

AbstractObjectiveTo study the effect of percutaneous paravalvular leak closure on hemolysis.BackgroundAlthough transcatheter PVL closure reduces heart failure and mortality in symptomatic patients with paravalvular leaks (PVL), little is known about its effect on hemolysis.MethodsWe retrospectively analyzed patients undergoing transcatheter mitral or aortic PVL closure (January 2005–December 2016) at Mayo Clinic. Patients with anemia or abnormal hemolysis markers (LDH, haptoglobin) were included in the analysis. The primary outcome was defined as hemoglobin increase ≥ 1.5 mg/dL, decrease in LDH above median or improvement in haptoglobin. Univariate and multivariate binary logistic regression modeling were used to determine predictors of successful treatment of hemolysis.ResultsFinal study population included 168 patients (130 [77%] mitral, 38 [23%] aortic PVL). Primary outcome occurred in 70 patients (42%). Hemoglobin increased by 1.74 ± 1.69 mg/dL in patients who reached primary outcome. 57/168 (34%) patients required blood transfusion prior to PVL closure compared to 35/168 (21%) postprocedure. The mean reduction in LDH was 403 U/L. Multivariate regression showed that patients with mechanical valves were more likely to have successful outcome (P = 0.044).ConclusionPercutaneous PVL closure is associated with modest improvement in hemolysis markers, increase in hemoglobin levels and reduction in blood transfusion requirements. This benefit is most significant in patients with mechanical valves.
Successful Percutaneous Mitral Paravalvular Leak Closure Is Associated With Improved Midterm Survival
Zack, Chad, Sarraf, Mohammad , Eleid, Mackram F. , Reeder, Guy S., Hagler, Donald J. , Maalouf, Joseph F., Rihal, Charanjit S. , Zack, Chad J, Cabalka, Allison K. , Alkhouli, Mohamad , Nkomo, Vuyisile T. , Rihal, Charanjit S.

Circulation: Cardiovascular Interventions | December 16, 2017 | Volume: 10 | Issue: 12 | Pages: No page available

10.1161/circinterventions.117.005730 Get It

Background— Percutaneous closure of prosthetic mitral valve paravalvular leak (PVL) has emerged as an alternative to surgical treatment in high-risk patients. Limited data exist on the impact of successful percutaneous PVL closure on midterm outcomes. Methods and Results— We examined consecutive patients who underwent percutaneous mitral PVL closure at Mayo Clinic, Rochester, MN, between January 2006 and January 2017. Procedural success, in-hospital outcomes, and midterm mortality were assessed. A total of 231 patients underwent percutaneous mitral PVL repair at a mean age of 67±12 years. Mean time from mitral valve replacement to percutaneous PVL repair was 1.25 (0.31–7.25) years. One hundred sixty-two patients (70%) had ≤mild PVL after the procedure. Compared with those who had >mild residual PVL, patients with ≤mild residual PVL had lower rates of repeat surgical interventions (6% versus 17%; P =0.004) and lower all-cause mortality at 30 days (1% versus 14%; P <0.001) and 1 year (15% versus 39%; P <0.001). Survival at 3 years was 61% in patients who had ≤mild residual leak and 47% in patients with higher grade of residual PVL ( P =0.002). Conclusions— In a large consecutive cohort of patients undergoing percutaneous mitral PVL closure, successful percutaneous reduction of the PVL to mild or less was associated with significant midterm survival benefit.
Hemodynamics of Fontan Failure
Egbe, Alexander C. , Connolly, Heidi M. , Miranda, William R. , Ammash, Naser M., Hagler, Donald J. , Veldtman, Gruschen , Borlaug, Barry A. , Veldtman, Gruschen R, Borlaug, Barry A

Circulation: Heart Failure | December 16, 2017 | Volume: 10 | Issue: 12 | Pages: No page available

10.1161/circheartfailure.117.004515 Get It

Background Nonpulsatile pulmonary blood flow in Fontan circulation results in pulmonary vascular disease, but the potential relationships between pulmonary vascular resistance index (PVRI) and Fontan failure have not been studied. The objective was to determine whether the absence of subpulmonary ventricle in the Fontan circulation would make patients more vulnerable to even low-level elevations in PVRI, and when coupled with low cardiac index, this would identify patients at increased risk of Fontan failure. Methods and Results Two hundred sixty-one adult Fontan patients underwent cardiac catheterization; age 26±3 years, men 146 (56%), atriopulmonary Fontan 144 (55%). Patients were divided into 2 groups: those with high PVRI (>2 WU·m 2 ) and low cardiac index <2.5 L min −1 m −2 (group 1, n=70, 30%), and those with normal PVRI and normal cardiac index (group 2, n=182, 70%). Fontan failure was defined by the composite of all-cause mortality, listing for heart transplantation, or initiation of palliative care. There were 68 (26%) cases of Fontan failure during a mean follow-up of 8.6±2.4 years. When compared with group 2, freedom from Fontan failure was significantly lower in group 1: 66% versus 89% at 5 years. The combination of high PVRI and low cardiac index was an independent risk factor for Fontan failure (hazard ratio, 1.84; 95% confidence interval, 1.09–2.85). Conclusions When coupled with low cardiac index, even mild elevations in PVRI identify patients at high risk of Fontan failure. This suggests that pulmonary vascular disease is a key mechanism underlying Fontan failure and supports further studies to understand the pathophysiology and target treatments to pulmonary vascular tone in this population.
Left atrial pressure and predictors of survival after percutaneous mitral paravalvular leak closure
Maor, Elad , Raphael, Claire E. , Panaich, Sidakpal , Hagler, Donald J. , Pollak, Peter , Reeder, Guy S., Eleid, Mackram F. , Rihal, Charanjit S. , Panaich, Sidakpal S, Cabalka, Allison, Hagler, Donald J , Pollak, Peter M, Eleid, Mackram F , Alkhouli, Mohamad , Cabalka, Allison K. , Rihal, Charanjit S. , Raphael, Claire , Panaich, Sidakpal S , Maor, Elad

Catheterization and Cardiovascular Interventions | July 14, 2017 | Volume: 90 | Issue: 5 | Pages: 861-869

10.1002/ccd.27179 Get It

AbstractBackgroundData on the clinical utility of left atrial (LA) hemodynamic monitoring during percutaneous mitral interventions are limited.ObjectivesTo evaluate the association between intraprocedural LA pressures during percutaneous mitral paravalvular leak (PVL) closure and long term survival.MethodsPatients who underwent mitral PVL repair with invasive LA pressure monitoring were divided at baseline to three tertiles based on their mean final LA pressure (<25%; 25‐30%; >30% of mean systolic blood pressure). Primary outcome was all‐cause mortality.Results134 patients (mean age 68 ± 12 years) were studied. Over 3 year mean follow‐up, 81 (38%) patients died. The cumulative probability of death at 3 years was significantly higher among patients in the highest LA pressure tertile (56 ± 8% vs. 28 ± 5%, log rank P < 0.001). More than mild residual mitral regurgitation (MR) by transesophageal echocardiography (TEE) was associated with a 2.5‐fold increased risk of death and patients in the highest LA pressure tertile had 2.2‐fold higher mortality (P < 0.001 and = 0.003 respectively). After adjustment for residual MR by TEE, each 10% acute procedural reduction in LA pressures was associated with a significant 9% reduced risk of death (P = 0.023). Multivariate Cox regression with adjustment for multiple predictors of death showed that patients in lower LA pressure tertiles had 59% lower mortality (P = 0.003).ConclusionLower LA pressure following mitral PVL closure is an independent predictor of improved survival, even after adjustment for residual MR. LA pressure monitoring may be a useful tool for procedural guidance during mitral PVL closure.
The Lababidi Procedure
Hagler, Donald J.

Catheterization and Cardiovascular Interventions | February 16, 2017 | Volume: 89 | Issue: 2 | Pages: 296-297

10.1002/ccd.26923 Get It

Key Points Long‐term risk of mortality, aortic insufficiency, and aortic valve replacement (AVR) reintervention are the objectives of the report. They discuss how this may impact our congenital interventional practice questioning which risk factors may be modifiable. Should the interventionalist be satisfied with a residual gradient of 30–35mm Hg and mild AR in the neonate?
Incidence, morphology, and progression of bicuspid aortic valve in pediatric and young adult subjects with coexisting congenital heart defects
Poterucha, Joseph T., Johnson, Jonathan N. , Craviari, Cecilia , Nienaber, Thomas , Palfreeman, Jared, Cetta, Frank , Hagler, Donald J. , Niaz, Talha

Congenital Heart Disease | November 28, 2016 | Volume: 12 | Issue: 3 | Pages: 261-269

10.1111/chd.12429 Get It

Intravascular and hybrid intraoperative stent placement for baffle obstruction in transposition of the great arteries after atrial switch
Poterucha, Joseph T., Taggart, Nathaniel W. , Johnson, Jonathan N. , Cannon, Bryan C. , Hagler, Donald J. , Cetta, Frank , Cabalka, Allison K. , Dearani, Joseph A. , Taggart, Nathaniel W

Catheterization and Cardiovascular Interventions | October 27, 2016 | Volume: 89 | Issue: 2 | Pages: 306-314

10.1002/ccd.26783 Get It

ObjectivesTo report our experience with intravascular and hybrid intra‐operative stent placement for baffle obstruction in patients with complete transposition of the great arteries (TGA) after the atrial switch (Mustard/Senning) operation.BackgroundVenous baffle obstruction is a challenging complication after atrial switch operation in patients with TGA. Traditional treatment options include intravascular stenting or surgery.MethodsA retrospective analysis of Mayo Clinic's electronic medical record was completed to identify consecutive pediatric and adult patients with TGA after atrial switch who underwent baffle stent implantation from 1994 to 2015.ResultsOverall, 64 patients were referred for cardiac catheterization, in whom 47 (73%) were noted to have hemodynamic and angiographic evidence of baffle obstruction. A total of 20 patients mean age 33 (range: 8–46) years old underwent stent implantation of baffle stenosis at a mean of 33 (range: 7.5–45) years after initial atrial switch operation (Mustard, n = 19; Senning, n = 1). Overall, 27 baffles were stented in 20 patients via the following approaches: intravascular (17); hybrid surgical (3); staged intravascular & hybrid (2). Sites of stent placement were: superior vena cava (SVC) (13); inferior vena cava (IVC) (9); pulmonary venous baffle (5). Three patients had stent placement in the SVC and IVC baffles during the same procedure. Procedural adverse events occurred in 2/22 cases (9%) including creation of unintentional baffle leak (n = 1) and stent migration (n = 1). There was no procedure‐related mortality. At follow‐up (median 2, range 0.02–10 years), significantly improved NYHA class and mean Doppler baffle gradient were demonstrated (P < 0.05). Mild baffle re‐stenosis (mean Doppler gradient; 2–3 mmHg) occurred in two patients who have not required re‐intervention. Trivial baffle leak was noted in four patients. Baffle re‐intervention was only occurred in one patient. One patient with pre‐procedural Class IV symptoms died 3.5 months after stent implantation.ConclusionsThis study is the largest reported experience of intravascular and intra‐operative hybrid stent placement for patients with TGA after atrial switch. Transcatheter and minimally invasive hybrid intraoperative surgical stent placement are an effective strategy for relief of systemic and pulmonary venous baffle obstruction. © 2016 Wiley Periodicals, Inc.
Good news and bad news
Hagler, Donald J.

Catheterization and Cardiovascular Interventions | September 13, 2016 | Volume: 88 | Issue: 3 | Pages: 444-445

10.1002/ccd.26713 Get It

Key Points: Current delivery systems for the Sapien XT valve for the native pulmonary valve are unacceptable stiff and poorly design for implantation in the pulmonary outflow tract. This report details improvisation of the Melody Ensemble for easier pulmonary outflow tract delivery of the Sapien XT valve. The unacceptable cost of the utilization of two delivery systems for valve implantation, requires industry development of an safe, effective delivery system appropriate for the pulmonary outflow tract.