Back to Authors

Sio, Terence T.

https://orcid.org/0000-0003-4210-5479

Mayo Clinic

Mayo Clinic in Arizona

Citations 70

The Search for Optimal Stereotactic Body Radiotherapy Dose in Inoperable, Centrally Located Non–Small-Cell Lung Cancer Continues
Mohindra, Pranshu , Yu, Nathan Y. , Ashman, Jonathan B. , Daniels, T.B., Merrell, Kenneth W. , Daniels, Thomas B, Schild, Steven E. , Mohindra, Pranshu , Sio, Terence T.

Journal of Clinical Oncology | August 29, 2019 | Volume: 37 | Issue: 29 | Pages: 2697-2699

10.1200/jco.19.01330 Get It

10-Year Locoregional Control with Postoperative External Beam Radiotherapy in Patients with Locally Advanced High-Risk Non-Anaplastic Thyroid Carcinoma De Novo or at Relapse, a Propensity Score Analysis
Vernat, S. Servagi, Khalifa, Jonathan , Sun, Xu-Shan, Kammerer, Emmanuel , Blais, E. , Pan, Jianji , Qiu, Hao , Bar‐Sela, Gil , Simon, Jean-Marc, Blais, Eivind , Sio, Terence Tai-Weng, Bar-Sela, Gil , Faivre, Jean Christophe , Sio, Terence T. , Simon, Jean-Marc, Salleron, Julia , Thariat, Juliette

Cancers | June 19, 2019 | Volume: 11 | Issue: 6 | Pages: 849

10.3390/cancers11060849 Get It

(1) Background: To assess the role of postoperative external beam radiotherapy (pEBRT) on locoregional failure (LRF) for patients with locally advanced high-risk non-anaplastic thyroid carcinoma (naTC) at primary event or relapse. (2) Methods: Between 1995 and 2015, postoperative naTC patients with a theoretical indication for EBRT were included based on criteria that were common to American-British-French current guidelines, i.e., pT3-4, pN+, gross or microscopic residual disease. Inverse probability of treatment weighting (IPTW) after multiple imputation was used to reduce selection biases. (3) Results: Of 254 naTC patients, 216 patients underwent pEBRT (106 de novo, 110 at relapse, median dose 60 Gy) and 38 underwent surgery only. pEBRT patients had more gross residual disease, a major prognostic factor (p = 0.027) but less perineural invasion (p = 0.008) or lymphovascular emboli (p = 0.009). pEBRT patients more frequently underwent radioiodine therapy (p = 0.026). The 10-year cumulative incidence of LRF was 56% (95% CI, 32–74%) in operated patients, and 23% (95% CI, 17–30%) in pEBRT patients. After IPTW method, pEBRT reduced the risk of LRF (hazard ratio 0.30; 95% CI [0.18–0.49], p < 0.001), but had no impact on OS. In the pEBRT group, non-Intensity Modulated RadioTherapy (IMRT) plans and interruption of the radiotherapy were associated with poorer survival, while extended versus limited field strategy and dose were not. (4) Conclusions: In naTC patients who have pT3-4, pN+ disease or R1-2 resection, pEBRT improved LRF. Limited-field IMRT is preferred.
Dosimetric comparison of distal esophageal carcinoma plans for patients treated with small‐spot intensity‐modulated proton versus volumetric‐modulated arc therapies
Liu, Chenbin , Bhangoo, R.S. , Yu, Nathan Y. , Shan, Jie , Chiang, Jennifer S. , Ding, Julia, Rule, William G., Korte, Shawn M., Lara, Pedro, Ding, Xiaoning, Hu, Yanle , DeWees, T.A. , Ashman, Jonathan B. , Bhangoo, Ronik S, Ding, Julia X, Korte, Shawn, Bues, Martin , DeWees, Todd, DeWees, Todd A , Sio, Terence T. , Liu, Wei

Journal of Applied Clinical Medical Physics | May 21, 2019 | Volume: 20 | Issue: 7 | Pages: 15-27

10.1002/acm2.12623 Get It

BackgroundEsophageal carcinoma is the eighth most common cancer in the world. Volumetric‐modulated arc therapy (VMAT) is widely used to treat distal esophageal carcinoma due to high conformality to the target and good sparing of organs at risk (OAR). It is not clear if small‐spot intensity‐modulated proton therapy (IMPT) demonstrates a dosimetric advantage over VMAT. In this study, we compared dosimetric performance of VMAT and small‐spot IMPT for distal esophageal carcinoma in terms of plan quality, plan robustness, and interplay effects.Methods35 distal esophageal carcinoma patients were retrospectively reviewed; 19 patients received small‐spot IMPT and the remaining 16 of them received VMAT. Both plans were generated by delivering prescription doses to clinical target volumes (CTVs) on phase‐averaged 4D‐CT's. The dose‐volume‐histogram (DVH) band method was used to quantify plan robustness. Software was developed to evaluate interplay effects with randomized starting phases for each field per fraction. DVH indices were compared using Wilcoxon rank‐sum test. For fair comparison, all the treatment plans were normalized to have the same CTVhigh D95% in the nominal scenario relative to the prescription dose.ResultsIn the nominal scenario, small‐spot IMPT delivered statistically significantly lower liver Dmean and V30Gy[RBE], lung Dmean, heart Dmean compared with VMAT. CTVhigh dose homogeneity and protection of other OARs were comparable between the two treatments. In terms of plan robustness, the IMPT and VMAT plans were comparable for kidney V18Gy[RBE], liver V30Gy[RBE], stomach V45Gy[RBE], lung Dmean, V5Gy[RBE], and V20Gy[RBE], cord Dmax and , liver Dmean, heart V20Gy[RBE], and V30Gy[RBE], but IMPT was significantly worse for CTVhigh D95%, , and D5%‐D95%, CTVlow D95%, heart Dmean, and V40Gy[RBE], requiring careful and experienced adjustments during the planning process and robustness considerations. The small‐spot IMPT plans still met the standard clinical requirements after interplay effects were considered.ConclusionsSmall‐spot IMPT decreases doses to heart, liver, and total lung compared to VMAT as well as achieves clinically acceptable plan robustness. Our study supports the use of small‐spot IMPT for the treatment of distal esophageal carcinoma.
Effect of Doxepin Mouthwash or Diphenhydramine-Lidocaine-Antacid Mouthwash vs Placebo on Radiotherapy-Related Oral Mucositis Pain
Leenstra, James L. , Loprinzi, Charles L. , Rine, G.P., Curtis, Amarinthia, Singh, Anurag K. , Martenson, James A., Novotny, Paul J. , Tan, Angelina D., Qin, Rui , Reiter, Paul L. , Miller, Robert C. , Ko, Stephen J. , Sio, Terence T. , Le‐Rademacher, Jennifer

JAMA | April 16, 2019 | Volume: 321 | Issue: 15 | Pages: 1481

10.1001/jama.2019.3504 Get It

Radiation Contamination Following Cremation of a Deceased Patient Treated With a Radiopharmaceutical
Yu, Nathan Y. , Rule, William G., Ashman, Jonathan B. , Nelson, Kevin L., Sio, Terence T.

JAMA | February 26, 2019 | Volume: 321 | Issue: 8 | Pages: 803

10.1001/jama.2018.21673 Get It

Dosimetric analysis of distal esophageal adenocarcinoma patients treated by intensity-modulated proton therapy with small spot size.
Liu, Chenbin , Bhangoo, R.S. , Rule, William G., Ross, Helen J. , Paripati, Harshita, Jaroszewski, Dawn E. , Beamer, Staci E. , Fleischer, David E., Ramirez, Francisco C. , Ding, Xiaoning, Ashman, Jonathan B. , Sio, Terence T. , Bues, Martin , Liu, Wei

Journal of Clinical Oncology | January 2, 2019 | Volume: 36 | Issue: 4_suppl | Pages: 159-159

10.1200/jco.2018.36.4_suppl.159 Get It

159 Background: Intensity-modulated proton therapy (IMPT) with small spot size has the potential to reduce dose to normal tissues but also introduces new confounding factors such as setup uncertainty, range uncertainty, and interplay effects due to breathing motion. We investigated plan quality and robustness of IMPT with small spot size for distal esophageal adenocarcinoma (DEA). Methods: 19 patients with DEA treated by IMPT were retrospectively evaluated. Spot sizes ranged from 2 to 6mm, with spot spacing of 5mm. All plans were generated using a commercial treatment planning system. In-house-developed dose-evaluation software modeled time-dependent spot delivery to incorporate interplay effects. Dose-volume-histogram (DVH) indices were used to evaluate plan quality and robustness was evaluated using the DVH band method. Results: For plan quality, median values of clinical target volume D95% and D5%-D95% (normalized to the prescribed doses), total lung mean dose, heart mean dose, and cord Dmax were 1.014, 0.035, 3.82Gy[RBE], 7.73Gy[RBE], 39.16Gy[RBE], respectively. For plan robustness, median band widths of the aforementioned DVH indices were 0.018, 0.048, 0.60Gy[RBE], 4.17Gy[RBE], and 2.36Gy[RBE], respectively. For interplay effects, median values of the aforementioned DVH indices were 0.99, 0.061, 4.07Gy[RBE], 7.87Gy[RBE], and 39.66Gy[RBE], respectively. Seven patients underwent esophagectomy after neoadjuvant chemoradiation, and five, three, and one of them achieved downstaging, near complete response, and pathologic complete response, respectively; R0 resection was achieved in all cases. For all patients, acute side effects were mostly limited to grades 1-2 only. The only grade 3 adverse events were related to feeding tube placement (8 patients); there were no RT-induced pneumonitis or other lung-related toxicities. Conclusions: IMPT plans with small spot size for DEA have good target dose coverage, homogeneity and normal tissue protection. Treatment plans are also robust to uncertainties and interplay effects. Early clinical results demonstrate low acute toxicity and encouraging clinical and pathologic response.
A novel and individualized robust optimization method using normalized dose interval volume constraints (NDIVC) for intensity‐modulated proton radiotherapy
Shan, Jie , Liu, Chenbin , Schild, Steven E. , Bues, Martin , Sio, Terence T. , Liu, Wei

Medical Physics | November 2, 2018 | Volume: 46 | Issue: 1 | Pages: 382-393

10.1002/mp.13276 Get It

PurposeIntensity‐modulated proton therapy (IMPT) is known to be sensitive to patient setup and range uncertainty issues. Multiple robust optimization methods have been developed to mitigate the impact of these uncertainties. Here, we propose a new robust optimization method, which provides an alternative way of robust optimization in IMPT, and is clinically practical, which will enable users to control the balance between nominal plan quality and plan robustness in a user‐defined fashion.MethodWe calculated nine individual dose distributions which corresponded to one nominal and eight extreme scenarios caused by patient setup and proton beam's range uncertainties. For each voxel, the normalized dose interval (NDI) is defined as the full dose range variation divided by the maximum dose in all uncertainty scenarios (NDI = [max – min dose]/max dose), which was then used to calculate the normalized dose interval volume histogram (NDIVH) curves. The areas under the NDIVH curves were used to quantify plan robustness. A normalized dose interval volume constraint (NDIVC) applied to the target was incorporated to specify the desired robustness which was user‐defined. Users could then explore the trade‐off between nominal plan quality and plan robustness by adjusting the position of the NDIVCs on the NDIVH curves freely. We benchmarked our method using one lung, five head and neck (H&N), and three prostate cases by comparing our results to those derived using the voxel‐wise worst‐case robust optimization.ResultsUsing the benchmark cases, our new method achieved quality IMPT plans comparable to those derived from the voxel‐wise worst‐case robust optimization for both nominal plan quality and plan robustness in general; even more conformal and more homogeneous target dose distributions in some cases, if proper NDIVCs were applied. The AUC under NDIVH, as a precise quantitative index of plan robustness, was consistent with DVH bandwidths. Additionally, we demonstrated the feasibility of adjusting the position of NDIVCs in the NDIVH curves which allowed users to explore the trade‐off between nominal plan quality and plan robustness.ConclusionsThe NDIVH‐based robust optimization method provided a novel and individualized way of robust optimization in IMPT, and enables users to adjust the balance between nominal plan quality and plan robustness in a user‐defined fashion. This method is applicable for continued improvement and developing the next generation of IMPT planning algorithms in the future.
Disseminated High-grade Glioma in a Long-term Survivor of Medulloblastoma
Porter, Alyx B. , Nelson, Kent D., Raghunathan, Aditya , Mrugala, Maciej , Raghunathan, Aditya , Sio, Terence T. , Bendok, Bernard R.

The Neurologist | October 30, 2018 | Volume: 23 | Issue: 6 | Pages: 191-193

10.1097/nrl.0000000000000199 Get It

We describe a gentleman diagnosed with a posterior fossa medulloblastoma in 1998, successfully treated with craniospinal radiation therapy (RT) and posterior fossa RT boost, followed by 12 months of adjuvant chemotherapy. Nineteen years later, at the age of 28, the patient presented with multiple cranial neuropathies and was found to have disseminated high-grade glioma with leptomeningeal dissemination. In addition to the salient features of this case, we provide a brief review of RT-induced malignancies and the need for further research regarding surveillance and prevention strategies.
Small‐spot intensity‐modulated proton therapy and volumetric‐modulated arc therapies for patients with locally advanced non‐small‐cell lung cancer: A dosimetric comparative study
Liu, Chenbin , Shan, Jie , Daniels, T.B., Rule, William G., Lara, Pedro R., Korte, Shawn M., Shen, Jiajian , Ding, Xiaoning, Daniels, Thomas B, Schild, Steven E. , Bues, Martin , Shen, Jiajian , Sio, Terence T. , Deng, Wei, Shan, Jie, Lara, Pedro R., Liu, Wei

Journal of Applied Clinical Medical Physics | October 17, 2018 | Volume: 19 | Issue: 6 | Pages: 140-148

10.1002/acm2.12459 Get It

AbstractPurposeTo compare dosimetric performance of volumetric‐modulated arc therapy (VMAT) and small‐spot intensity‐modulated proton therapy for stage III non‐small‐cell lung cancer (NSCLC).Methods and MaterialsA total of 24 NSCLC patients were retrospectively reviewed; 12 patients received intensity‐modulated proton therapy (IMPT) and the remaining 12 received VMAT. Both plans were generated by delivering prescription doses to clinical target volumes (CTV) on averaged 4D‐CTs. The dose‐volume‐histograms (DVH) band method was used to quantify plan robustness. Software was developed to evaluate interplay effects with randomized starting phases of each field per fraction. DVH indices were compared using Wilcoxon rank sum test.ResultsCompared with VMAT, IMPT delivered significantly lower cord Dmax, heart Dmean, and lung V5 Gy[RBE] with comparable CTV dose homogeneity, and protection of other OARs. In terms of plan robustness, the IMPT plans were statistically better than VMAT plans in heart Dmean, but were statistically worse in CTV dose coverage, cord Dmax, lung Dmean, and V5 Gy[RBE]. Other DVH indices were comparable. The IMPT plans still met the standard clinical requirements with interplay effects considered.ConclusionsSmall‐spot IMPT improves cord, heart, and lung sparing compared to VMAT and achieves clinically acceptable plan robustness at least for the patients included in this study with motion amplitude less than 11 mm. Our study supports the usage of IMPT to treat some lung cancer patients.
Technical Note: Using dual step wedge and 2D scintillator to achieve highly precise and robust proton range quality assurance
Robertson, Daniel , Keole, Sameer R., Shen, Jiajian , Robertson, Daniel G, Bues, Martin , Shen, Jiajian , Deng, Wei , Liu, Wei , Sio, Terence T.

Medical Physics | May 13, 2018 | Volume: 45 | Issue: 7 | Pages: 2947-2951

10.1002/mp.12951 Get It

PurposeThe purpose of this study was to develop a fast method for proton range quality assurance (QA) using a dual step wedge and two‐dimensional (2D) scintillator and to evaluate the robustness, sensitivity, and long‐term reproducibility of this method.MethodsAn in‐house customized dual step wedge and a 2D scintillator were developed to measure proton ranges. Proton beams with homogenous fluence were delivered through wedge, and the images captured by the scintillator were used to calculate the proton ranges by a simple trigonometric method. The range measurements of 97 energies, comprising all clinically available synchrotron energies at our facility (ranges varying from 4 to 32 cm) were repeated ten times in all four gantry rooms for range baseline values. They were then used for evaluating room‐to‐room range consistencies. The robustness to setup uncertainty was evaluated by measuring ranges with ±2 mm setup deviations in the x, y, and z directions. The long‐term reproducibility was evaluated by 1 month of daily range measurements by this method.ResultsRanges of all 97 energies were measured in less than 10 minutes including setup time. The reproducibility in a single day and daily over 1 month is within 0.1 and 0.15 mm, respectively. The method was very robust to setup uncertainty, with measured range consistencies within 0.15 mm for ±2 mm couch shifts. The method was also sensitive enough for validating range consistencies among gantry rooms and for detecting small range variations.ConclusionsThe new method of using a dual step wedge and scintillator for proton range QA was efficient, highly reproducible, and robust. This method of proton range QA was highly feasible and appealing from a workflow point of view.