B-231 Evaluation of the KingFisher Flex for DNA Isolation From FFPE Tissue Utilizing Autolys M Tubes and the MagMAX FFPE DNA/RNA Ultra Kit
Zuckerman, Eric Zimmerman , Caffes, Patricia L., Marta, Paz, Lockwood, Nicola , Dukek, Brian A. , Baumann, N, Rowsey, Ross, Knight, S, Milosevic, D, Lockwood, N

Clinical Chemistry | October 2, 2024 | Volume: 70 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvae106.590 Get It

Abstract Background Our institution is facing increasing demand for oncology testing that requires high quality DNA extracted from formalin-fixed paraffin-embedded (FFPE) tissue. The current DNA extraction workflow involves a time and labor-intensive manual process that limits our ability to accommodate increasing downstream clinical testing volumes. We evaluated the KingFisher (KF) Flex utilizing Autolys M Tubes and the MagMAX FFPE DNA/RNA Ultra Kit as a possible high-throughput, automated DNA isolation workflow option that would decrease hands-on time and be conducive to volume growth without the need for additional staff. Methods DNA from 52 FFPE tissue samples (n=24 unique cases previously extracted by the current “manual method”) were extracted using Autolys M tubes, the MagMAX FFPE DNA/RNA Ultra Kit, and the KF Flex (Thermo Fisher Scientific Waltham, MA) over 4 “automated method” runs. Method modifications to the published procedure were introduced over the runs to determine any effects on DNA quality/quantity. Timings were taken during each run to compare hands-on and total run time against that of the manual method. Precision experiments were performed by extracting 4 replicates of sample on a single run (intra-assay precision) and 2 samples from 2 cases over 2 runs (inter-assay precision). Three cases were processed using varying tissue input levels to assess input-yield correlation. DNA yield was measured using HS dsDNA Qubit (Thermo Fisher Scientific, Waltham, MA). A subset of samples was tested by digital droplet PCR (ddPCR) (n=10), chromosomal microsomal microarray (CMA) (n=1), and next-generation sequencing (NGS) (n=3). Variants and QC metrics of the KF DNA were compared to those of the manual method DNA. Results The average total DNA yield was 3% lower from samples extracted following the manufacturer recommended KF procedure compared to matched samples extracted using the manual method (n=28 samples from 23 unique cases). A CV of 2.8% was observed in an intra-assay experiment (n=4 replicates from 1 case) and 3.0% in an average inter-assay experiment (n=2 replicates from 2 cases). There was a direct correlation between the tissue input amount (4 amounts of varied tissue input) and the total DNA yield (n=3 samples). We observed concordant fractional abundance values for ddPCR samples and concordant variant detection for NGS and CMA samples. We did not see a significant difference in the quality metrics tracked for any of the downstream testing assays. Conclusions This evaluation demonstrated that, as compared to our manual method, the automated method resulted in comparable DNA yields and downstream assay results. The incorporation of this automation would significantly increase our FFPE DNA extraction capacity without requiring additional staff while reducing hands-on time per run by about six hours. We would also be able to reduce ergonomic hazards related to tube cap manipulation, eliminate use of hazardous reagents, and leverage the plate format to better integrate extracted DNA into our clinical sample preparation workflows. These operational benefits highlight the value of automating high-throughput workflows.
Expanding the phenotypic spectrum of lipomatosis of the sciatic nerve: Early‐onset colonic diverticular disease
Marek, Tomáš , Amrami, Kimberly K. , Blackburn, Patrick R. , Caffes, Patricia L., Carter, Jodi M. , Camilleri, Michael , Spinner, Robert J. , Camilleri, M , Spinner, Robert J , Carter, Jodi , Mahan, Mark A

Neurogastroenterology & Motility | June 22, 2020 | Volume: 32 | Issue: 10 | Pages: No page available

10.1111/nmo.13917 Get It

AbstractBackgroundLipomatosis of nerve (LN) is a complex peripheral nerve disorder characterized by fibrofatty nerve enlargement. MRI of this pathology is pathognomonic and obviates a diagnostic biopsy. Mutation in PIK3CA has been associated with LN cases with nerve‐territory overgrowth which may occur in some cases. We evaluate an association of LN of the sciatic nerve and early‐onset colonic diverticular disease and discuss the potential pathogenesis.MethodsOur institutional database was searched for LN cases. Available information of identified cases was reviewed, and cases with a confirmed diagnosis of LN affecting the lumbosacral plexus and/or sciatic nerve; available MRI of the affected nerve(s); and diverticular disease occurring in the area supplied by the nerve(s) affected by LN were further analyzed. PIK3CA mutation testing was performed on available tissue samples.ResultsWe identified 10 LN cases of lumbosacral plexus and/or sciatic nerve. Of these, three fulfilled our inclusion criteria. All three patients had concomitant colonic diverticular disease, diagnosed at a relatively young age. MRI studies of these cases showed LN involvement of the sacral nerves innervating the sigmoid colon. All three also had abnormal diagnostic workup including various GI tests and evidence of associated nerve‐territory overgrowth. Colonic tissue samples for PIK3CA mutation were negative.ConclusionWhile the pathogenesis of the colonic diverticular disease is increasingly recognized as being multifactorial, our observations are consistent with the potential role of autonomic nervous system dysfunction affecting either the pelvic floor musculature, or the colon itself (or both) in a subset of patients with early‐onset diverticular disease.
Major Basic Protein Homolog (MBP2): A Specific Human Eosinophil Marker
Plager, Douglas A., Loegering, David A., Checkel, James L., Tang, Junger, Kephart, Gail M., Caffes, Patricia L., Adolphson, Cheryl R., Ohnuki, Lyo E., Gleich, Gerald J.

The Journal of Immunology | April 18, 2014 | Volume: 177 | Issue: 10 | Pages: 7340-7345

10.4049/jimmunol.177.10.7340 Get It

Abstract Human eosinophil granule major basic protein (MBP1) is an exceedingly basic (isoelectric point >11) 14-kDa protein, comprising the core of the secondary eosinophil granule. Recently, a less cationic homolog of MBP, termed MBPH or simply, MBP2, has been discovered. We prepared a panel of mAbs to MBP2 and used these Abs to localize and quantitate this molecule in leukocytes and biological fluids. Specific mAbs for MBP2 were selected using slot-blot analyses and used in a two-site immunoassay, Western blotting, and immunofluorescence microscopy. The sensitivity of the immunoassay was markedly improved by reduction and alkylation of MBP2. MBP1 is more abundant than MBP2 in lysates of eosinophils and their granules, as judged by immunoassay and Western blotting. By immunofluorescence, MBP1 is present in eosinophils, basophils, and a human mast cell line (HMC1), whereas MBP2 is only detected in eosinophils. Neither MBP1 nor MBP2 could be detected in any other peripheral blood leukocyte. MBP2 levels measured in plasma and serum were essentially identical. In contrast to past measurements for MBP1, MBP2 was not detected above normal levels in sera from pregnant donors. However, measurement of serum MBP2 discriminated patients with elevated eosinophils from normal subjects, and MBP2 was also detectable in other biological specimens, such as bronchoalveolar lavage, sputum, and stool. These results indicate that MBP2 is present only in eosinophils and that it may be a useful biomarker for eosinophil-associated diseases.