Back to Authors

Johnson, Bruce D.

Mayo Clinic

Mayo Clinic

Citations 3

The Metabolic Cost Of Steep Incline Treadmill Walking
Yeo, Dongwook , Carlson, Alex R., Johnston, Jessi I., Ziegler, Briana, Wentz, Robert J., Olson, Lucas A., Hunter Downs, J., Kim, Chul-Ho, Johnson, Bruce D., Carlson, Alex R. , Johnston, Jessica I., Wentz, Robert J., Kim, Chul‐Ho , Johnson, Bruce D.

Medicine & Science in Sports & Exercise | September 18, 2026 | Volume: 58 | Issue: 10S | Pages: No page available

10.1249/01.mss.0001263140.75996.84 Get It

Estimating Blood Volume Loss With Wireless, Wearable Ultrasound: A Pilot Investigation
Kenny, Jon‐Émile S. , Savery, Tracy, Lachner-Piza, Daniel, Eibl, Andrew M., Eibl, Joseph K. , Vungarala, Soumya , Dietz, Niki M., Kim, Chul-Ho, Johnson, Bruce D, Hebscher, Melissa , Atwi, Sarah , Piza, Daniel Lachner , Johnson, Bruce D.

Military Medicine | April 2, 2026 | Volume: 191 | Issue: Supplement_1 | Pages: 386-392

10.1093/milmed/usag109 Get It

Abstract Introduction Detecting and estimating blood volume loss are important for the diagnosis and management of life-threatening hemorrhage. There is a direct relationship between percent blood volume loss (BVL%) and falling in stroke volume (SV); furthermore, there is a direct relationship between diminishing SV and the corrected flow time of the carotid artery (ccFT). Therefore, we hypothesized that change in ccFT (ccFTΔ) would directly relate with BVL% in a phlebotomy paradigm. Materials and Methods A prospective, convenience sample of healthy volunteers was studied. Volunteers underwent blood donation protocol in a physiology lab. A wireless, wearable Doppler ultrasound system monitored ccFT during blood donation. Traditional vital signs were also measured throughout. The relationship between traditional vital signs as well as ccFTΔ were compared to BVL% using 2 mixed linear regression models. Results Data from 20 subjects and blood donations comprising 46,123 cardiac cycles are included. On average 413.5 ± 39 mL of blood were drawn representing 8.6 ± 1.6% BVL%. There was a significant and strong linear relationship between BVL% and ccFTΔ during blood draw with the regression slope demonstrating that for every 1 ms reduction in ccFT there was a 0.4% reduction in blood volume. Conclusions In healthy subjects and when blood loss is the sole mechanism for falling SV, we estimate that for every 1 ms reduction in ccFT, there is an approximate 0.4 BVL%. Validation of these results in patients with traumatic hemorrhage is underway.
A Hemodynamic Lens on Inspiratory Muscle Strength Exercise
Yeo, Dongwook , Johnson, Bruce D., Kim, Chul-Ho, Kim, Chul‐Ho , Kim, Chul-Ho , Johnson, Bruce D.

The Korean Journal of Sports Medicine | February 27, 2026 | Volume: 44 | Issue: 1 | Pages: 1-3

10.5763/kjsm.2026.44.1.1 Get It