Abstract Introduction Detecting and estimating blood volume loss are important for the diagnosis and management of life-threatening hemorrhage. There is a direct relationship between percent blood volume loss (BVL%) and falling in stroke volume (SV); furthermore, there is a direct relationship between diminishing SV and the corrected flow time of the carotid artery (ccFT). Therefore, we hypothesized that change in ccFT (ccFTΔ) would directly relate with BVL% in a phlebotomy paradigm. Materials and Methods A prospective, convenience sample of healthy volunteers was studied. Volunteers underwent blood donation protocol in a physiology lab. A wireless, wearable Doppler ultrasound system monitored ccFT during blood donation. Traditional vital signs were also measured throughout. The relationship between traditional vital signs as well as ccFTΔ were compared to BVL% using 2 mixed linear regression models. Results Data from 20 subjects and blood donations comprising 46,123 cardiac cycles are included. On average 413.5 ± 39 mL of blood were drawn representing 8.6 ± 1.6% BVL%. There was a significant and strong linear relationship between BVL% and ccFTΔ during blood draw with the regression slope demonstrating that for every 1 ms reduction in ccFT there was a 0.4% reduction in blood volume. Conclusions In healthy subjects and when blood loss is the sole mechanism for falling SV, we estimate that for every 1 ms reduction in ccFT, there is an approximate 0.4 BVL%. Validation of these results in patients with traumatic hemorrhage is underway.
The Correlation between Carotid Artery Corrected Flow Time and Velocity Time Integral during Central Blood Volume Loss and Resuscitation
Abstract Background: Doppler ultrasound of the common carotid artery is used to infer central hemodynamics. For example, change in the common carotid artery corrected flow time (ccFT) and velocity time integral (VTI) are proposed surrogates of changing stroke volume. However, conflicting data exist which may be due to inadequate beat sample size and measurement variability – both intrinsic to handheld systems. In this brief communication, we determined the correlation between changing ccFT and carotid VTI during progressively severe central blood volume loss and resuscitation. Methods: Measurements were obtained through a novel, wireless, wearable Doppler ultrasound system. Sixteen participants (ages of 18–40 years with no previous medical history) were studied across 25 lower body-negative pressure protocols. Relationships were assessed using repeated-measures correlation regression models. Results: In total, 33,110 cardiac cycles comprise this analysis; repeated-measures correlation showed a strong, linear relationship between ccFT and VTI. The strength of the ccFT-VTI relationship was dependent on the number of consecutively averaged cardiac cycles (R 1 cycle = 0.70, R 2 cycles = 0.74, and R 10 cycles = 0.81). Conclusions: These results positively support future clinical investigations employing common carotid artery Doppler as a surrogate for central hemodynamics.