Back to Authors

Breakspear, Michael J

0000-0003-4943-3969

Mayo Clinic

Hunter Medical Research Institute

Citations 3

Gradients in excitability generate hippocampal waves and shape their interactions with cortex
Behler, Anna , Phogat, Richa , Jones, David T. , Shine, James, Breakspear, Michael , Jones, David T , Shine, James M. , Breakspear, Michael J

No container title available | May 29, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.05.27.728116 Get It

Abstract Travelling waves are a prominent feature of hippocampal activity, but the mechanisms determining their propagation and influence on the cerebral cortex remain unclear. Using a biophysically-grounded model of neural activity evolving across hippocampal and cortical surfaces, we show that spatial gradients in external in-put or neural excitability are a sufficient mechanism for the emergence of travelling waves along the long axis of the hippocampus. These waves emerge only above a critical gradient threshold, propagate with biologically-plausible velocities and exhibit frequency-dependent reversals in direction across slow and fast theta regimes. When coupled to the cerebral cortex, anterior-to-posterior hippocampal waves selectively reorganise globally synchronous cortical activity into metastable travelling waves, whereas posterior-to-anterior hippocampal waves do not, revealing a directional asymmetry in hippocampal–cortical communication. Conversely, cortical waves aligned with large-scale functional gradients induce structured hippocampal waves, revealing complementary direction specific effects across the two systems. These analyses identify structured excitability gradients as a principle governing wave propagation in the hippocampus and suggest how wave-to-wave interactions may coordinate complex cortical and hippocampal interactions during mnemonic and perceptual processes.
AI‐enhanced Centiloid quantification of amyloid PET images
Bourgeat, Pierrick , Fripp, Jurgen, Lebrat, Léo , Xia, Ying, Zisis, Georgios , Goyal, Manu S., Tosun, Duygu, Benzinger, Tammie LS., Breakspear, Michael J, Short, Cathy, Adam, Robert , Robertson, Joanne, Sperling, Reisa, O'Bryant, Sid E., Johnson, Sterling C., Jr, Clifford R. Jack, Schwarz, Christopher G., Barkhof, Frederik, Farrar, Gill , Bollack, Ariane, Collij, Lyduine E., Landau, Susan, Koeppe, Robert, Initiative, for the Alzheimer's Disease Neuroimaging, OASIS3, Team, the A4/LEARN Study, Team, The Health and Aging Brain Study (HABS‐HD) Study, WRAP, ADNI‐DOD, PISA, ADNeT, Morris, John C., Weiner, Michael W., Villemagne, Victor L., Masters, Colin L., Rowe, Christopher C., Doré, Vincent , Barkhof, Frederik , Bourgeat, Pierrick , Xia, Ying , Barkhof, Frederik , Xia, Ying , Doré, Vincent , Fripp, Jürgen , Xia, Ying, Feizpour, Azadeh , Cox, Timothy O. , Gillman, Ashley , Goyal, Manu S. , Benzinger, Tammie L.S. , LaMontagne, Pamela , Breakspear, Michael J , Lupton, Michelle K. , Short, Cathy, Sperling, Reisa Anne , O’Bryant, Sid E. , Johnson, Sterling C. , Jack, Clifford R. , Schwarz, Christopher G. , Bollack, Ariane , Collij, Lyduine , Landau, Susan , Koeppe, Robert A. , Initiative, for the Alzheimer’s Disease Neuroimaging, Morris, John C. , Weiner, Michael W. , Villemagne, Victor L. , Masters, Colin L. , Rowe, Christopher Cleon

Alzheimer's & Dementia | February 11, 2026 | Volume: 22 | Issue: 2 | Pages: No page available

10.1002/alz.71162 Get It

Abstract INTRODUCTION The Centiloid scale is the standard for amyloid (Aβ) PET quantification in research and clinical settings. However, variability between tracers and scanners remains a challenge. METHODS This study introduces DeepSUVR, a deep learning method to correct Centiloid quantification, by penalizing implausible longitudinal trajectories during training. The model was trained using data from 2,129 participants (7,149 Aβ positron emission tomography [PET] scans) in the Australian Imaging, Biomarkers and Lifestyle Study of ageing (AIBL)/Alzheimer's Disease Neuroimaging Initiative (ADNI) and validated using 15,807 Aβ PET scans from 10,543 participants across 10 external datasets. RESULTS DeepSUVR increased correlation between tracers, and reduced variability in the Aß‐negatives. It showed significantly stronger association with cognition, visual reads, neuropathology, and increased longitudinal consistency between studies. DeepSUVR also increased the effect size for detecting small treatment related slowing of amyloid accumulation in the A4 study. DISCUSSION DeepSUVR substantially advances Aβ PET quantification, outperforming all standard approaches, which is particularly important for clinical decision making and to detect subtle or early changes in Aβ. Highlights Novel artificial intelligence (AI)‐method that penalizes biologically implausible longitudinal trajectories, enabling the model to learn standardized uptake value ratios (SUVR) correction factors without requiring longitudinal data at inference time. Improves Centiloid consistency across tracers and studies, significantly enhancing cross‐sectional and longitudinal amyloid positron emission tomography (PET) quantification. DeepSUVR‐derived Centiloids show stronger associations with cognition, visual reads, and neuropathology. Longitudinal variability is reduced three‐ to five‐fold, enabling more reliable tracking of amyloid accumulation and better detection of treatment effects. Novel reference and target masks derived from DeepSUVR replicate most of the model's performance, offering a practical alternative for integration into existing pipelines.
Revisiting Centiloids using AI
Bourgeat, Pierrick , Xia, Ying , Feizpour, Azadeh , Zisis, Georgios , Goyal, Manu S. , Tosun, Duygu , Short, C, Adam, Robert , Robertson, Joanne, Park, Denise C. , Farrar, Gill , Bollack, Ariane , Landau, Susan , Koeppe, Robert, Morris, John, Weiner, Michael, Villemagne, Victor L. , Masters, Colin, Doré, Vincent , Xia, Ying , Feizpour, Azadeh , Goyal, Manu , Tosun, Duygu , Benzinger, Tammie L S , LaMontagne, Pamela , Sperling, Reisa Anne , O'Bryant, Sid , Johnson, Sterling C. , Jack, Clifford R , Schwarz, Christopher G , Park, Denise C , Collij, Lyduine , Rowe, Christopher Cleon , Doré, Vincent , Bourgeat, Pierrick , Fripp, Jürgen , Lebrat, Léo , Cox, Timothy O. , Gillman, Ashley , Benzinger, Tammie L.S. , Breakspear, Michael J , Lupton, Michelle K. , Short, Cathy, O’Bryant, Sid E. , Jack, Clifford R. , Schwarz, Christopher G. , Barkhof, Frederik , Masters, Colin

No container title available | July 8, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-7015694/v1 Get It

Abstract The Centiloid scale is the standard for Amyloid (Aβ) PET quantification, widely used in research, clinical settings, and trial stratification. However, variability between tracers and scanners remains a challenge. This study introduces DeepSUVR, a deep learning method to correct Centiloid quantification, by penalising implausible longitudinal trajectories during training. The model was trained using data from 2,098 participants (6,762 Aβ PET scans) in AIBL/ADNI and validated using 15,806 Aβ PET scans from 10,543 participants across 10 external datasets. DeepSUVR increased correlation between tracers, and reduced variability in the Aβ-negatives. It showed the strongest association with cognition, highest AUC against visual reads and best longitudinal consistency between studies. DeepSUVR also increased the effect size for detecting lower Centiloid increase per year in the A4 study. DeepSUVR advances Aβ PET quantification, outperforming standard approaches, which is particularly important for consistent decision making and to detect subtle and early changes in clinical interventions.