Back to Authors

Woodhead, Zoe

0000-0003-0462-6791

Mayo Clinic

Brainomix (United Kingdom)

Citations 2

Abstract 295: Prospective comparison of core and penumbra volumes from two CT perfusion quantification software packages
Wolfe, Jared , Mendis, D. A. , Beegle, Richard D. , Johnny, Shinn-Nan, Nord, Charisse A., Pahl, Elfriede , Wood, Stephen , FERNANDEZ, CLAIRE, English, S., Demaerschalk, Bart M. , Pahl, E., Wood, S., Woodhead, Zoe , Carone, Davide , Harston, George

Stroke: Vascular and Interventional Neurology | December 2, 2025 | Volume: 5 | Issue: S1 | Pages: No page available

10.1161/svi270000_295 Get It

Introduction Software packages for quantification of CT perfusion parameters allow quick visualization of perfusion deficits to support clinical decision making in acute ischemic stroke (AIS). Several packages are now commercially available for automated quantification of ischemic core, penumbra volumes, and mismatch ratios to indicate eligibility for reperfusion therapies. This study explored the agreement between two software packages, Brainomix 360 e‐CTP and Rapid CTP, in prospective, real‐world use. Methods Consecutive patients scanned for suspected stroke at three comprehensive stroke centers over 90 days from May to July 2024 were included in the study. Eligibility for the current analysis was limited to discharge diagnosis of AIS and CTP imaging processed by both Brainomix and Rapid software. Software processing was conducted in real time after image acquisition. The presence of large vessel occlusion (LVO) was determined from review of electronic medical records. CTP core (CBF<30%) and penumbra (Tmax>6s) volumes from Brainomix and Rapid were recorded for each case. Mismatch ratios were calculated (penumbra÷core volume); positive mismatch was defined according to DEFUSE‐3 criteria (core<70ml, penumbra>15ml, mismatch ratio > 1.8). The correlations and linear regressions between Brainomix and Rapid were computed for core, penumbra and mismatch ratios, and their concordance for mismatch positivity was assessed. Results 137 patients were scanned and received a final diagnosis of AIS. Of these, only 38 had imaging processed by both Brainomix and Rapid. Median age was 69 years (interquartile range: 57‐77.5y); 16 (42%) were female; 13 (34%) had LVO. Linear models between Brainomix and Rapid's outputs for CBF and Tmax volumes are shown in Figure 1a and 1b. The correlation between software outputs for CBF volume was r=0.70 (p<.001), and for Tmax volume was r=0.72 (p<.001). Mismatch ratios were calculated for the 13 cases with LVO (Figure 1c). The linear model between mismatch ratios was not significant, with four Rapid outputs showing infinite mismatch ratios (due to having CBF volumes of 0ml). Concordance between software for mismatch positivity was good; 8/13 cases showed mismatch on both softwares; 1 case showed mismatch on Brainomix only; 1 for Rapid only; and 3 cases showed mismatch on neither software. Conclusion This prospective study, despite limited sample size (N=38), showed good correlations between Brainomix 360 e‐CTP and Rapid CTP for calculation of both core and penumbra volumes. Although mismatch ratios showed less agreement, the categorization of mismatch positivity showed good concordance between software platforms. image
Abstract TP86: Evaluating the Implementation of Brainomix 360 AI Stroke Software in a Robust Academic Hub-and-Spoke Telestroke Network
Smith, Brett, Wolfe, Jackson, Karam, Arnaud , Hrdlicka, Courtney M. , Nasr, Deena M. , Chukwudelunzu, Felix E. , Nord, Charisse, Pahl, Emily, English, Stephen , Smith, Brett, Wolfe, Jackson, Demaerschalk, Bart M. , Woodhead, Zoe , Harston, George

Stroke | January 30, 2025 | Volume: 56 | Issue: Suppl_1 | Pages: No page available

10.1161/str.56.suppl_1.tp86 Get It

Background: Artificial intelligence (AI) stroke imaging software is becoming mainstay in many hub-and-spoke hospitals. Brainomix 360 Stroke software is the market leader in Europe focused on leveraging simple imaging (non-contrast computerized topography (NCCT) and CT angiography (CTA)) and has recently been FDA-cleared for use in the USA. We evaluated the implementation of Brainomix 360 AI Stroke software in the 17 spoke, multi-state Mayo Clinic Health System (MCHS) telestroke network. Methods: This prospective study compared decision and treatment times before and after Brainomix AI implementation, as well as clinician feedback and simulated decision making to better understand any changes seen. Patients were included if they underwent telestroke evaluation at an MCHS emergency department within 90 days of implementation (2/9/2024-8/8/2024), and excluded if they were already admitted to the hospital or if video evaluation was not performed. Data collection included demographics, clinical decisions and treatment times. Qualitative surveys were conducted at baseline and evaluation end, as well as simulated decision making in 20 de-identified cases randomized to with/without AI through an online portal. Results: A total of 907 patients were included (444 pre- and 463 post-implementation, 287 (32%) with ischemic stroke final diagnosis). Median NIHSS was 2. IVT was recommended in 20.3% (27/148 ischemic stroke patients) pre- and 25.9% (36/139) post-implementation. EVT was recommended in 16.2% (24/148) pre and 14.4% (20/139) post. AI use was associated with trends of faster telestroke activation to IVT decision (36 vs 32 mins, p=0.6), IVT administration (47 vs 40 minutes, p=0.6), and EVT decision (36 vs 33 minutes, p=0.5). In the simulation, imaging interpretation was significantly faster when randomized to AI use (3.4 vs 2.1 mins, p<0.001) and associated with improved physician confidence (62 vs 88%, p=0.004). Qualitative feedback from 14/24 neurologists showed the greatest perceived value was improved confidence of treatment decisions (43%) and faster triaging (36%). Most value was gained from e-ASPECTS (NCCT) and LVO modules. Conclusion: This service evaluation highlighted the opportunity to improve efficiency of decision making even in the setting of a well-developed telestroke system. The impact was underpinned by the improved speed and confidence of imaging interpretation reflected in an offline simulation and qualitative feedback.