Abstract 295: Prospective comparison of core and penumbra volumes from two CT perfusion quantification software packages
Wolfe, Jared , Mendis, D. A. , Beegle, Richard D. , Johnny, Shinn-Nan, Nord, Charisse A., Pahl, Elfriede , Wood, Stephen , FERNANDEZ, CLAIRE, English, S., Demaerschalk, Bart M. , Pahl, E., Wood, S., Woodhead, Zoe , Carone, Davide , Harston, George

Stroke: Vascular and Interventional Neurology | December 2, 2025 | Volume: 5 | Issue: S1 | Pages: No page available

10.1161/svi270000_295 Get It

Introduction Software packages for quantification of CT perfusion parameters allow quick visualization of perfusion deficits to support clinical decision making in acute ischemic stroke (AIS). Several packages are now commercially available for automated quantification of ischemic core, penumbra volumes, and mismatch ratios to indicate eligibility for reperfusion therapies. This study explored the agreement between two software packages, Brainomix 360 e‐CTP and Rapid CTP, in prospective, real‐world use. Methods Consecutive patients scanned for suspected stroke at three comprehensive stroke centers over 90 days from May to July 2024 were included in the study. Eligibility for the current analysis was limited to discharge diagnosis of AIS and CTP imaging processed by both Brainomix and Rapid software. Software processing was conducted in real time after image acquisition. The presence of large vessel occlusion (LVO) was determined from review of electronic medical records. CTP core (CBF<30%) and penumbra (Tmax>6s) volumes from Brainomix and Rapid were recorded for each case. Mismatch ratios were calculated (penumbra÷core volume); positive mismatch was defined according to DEFUSE‐3 criteria (core<70ml, penumbra>15ml, mismatch ratio > 1.8). The correlations and linear regressions between Brainomix and Rapid were computed for core, penumbra and mismatch ratios, and their concordance for mismatch positivity was assessed. Results 137 patients were scanned and received a final diagnosis of AIS. Of these, only 38 had imaging processed by both Brainomix and Rapid. Median age was 69 years (interquartile range: 57‐77.5y); 16 (42%) were female; 13 (34%) had LVO. Linear models between Brainomix and Rapid's outputs for CBF and Tmax volumes are shown in Figure 1a and 1b. The correlation between software outputs for CBF volume was r=0.70 (p<.001), and for Tmax volume was r=0.72 (p<.001). Mismatch ratios were calculated for the 13 cases with LVO (Figure 1c). The linear model between mismatch ratios was not significant, with four Rapid outputs showing infinite mismatch ratios (due to having CBF volumes of 0ml). Concordance between software for mismatch positivity was good; 8/13 cases showed mismatch on both softwares; 1 case showed mismatch on Brainomix only; 1 for Rapid only; and 3 cases showed mismatch on neither software. Conclusion This prospective study, despite limited sample size (N=38), showed good correlations between Brainomix 360 e‐CTP and Rapid CTP for calculation of both core and penumbra volumes. Although mismatch ratios showed less agreement, the categorization of mismatch positivity showed good concordance between software platforms. image