Short-Term Outcomes of Heart Transplant Patients Bridged with Impella 5.5 Ventricular Assist Device
Haddad, Osama , Sareyyüpoğlu, Başar , Goswami, Rohan , Bitargil, Macit , Patel, Parag C. , Jacob, Samuel , Ahmed, Magdy M. El‐Sayed , Leoni, Juan , Yip, Daniel , Landolfo, Kevin , Leoni Moreno, Juan Carlos, Pham, Si M. , Goswami, Rohan , Leoni, Juan Carlos

ESC Heart Failure | May 3, 2023 | Volume: 10 | Issue: 4 | Pages: 2298-2306

10.1002/ehf2.14391 Get It

Abstract Aims We sought to investigate the outcomes of heart transplant patients supported with Impella 5.5 temporary mechanical circulatory support. Methods and results Patient demographics, perioperative data, hospital timeline, and haemodynamic parameters were followed during initial admission, Impella support, and post-transplant period. Vasoactive-inotropic score, primary graft failure, and complications were recorded. Between March 2020 and March 2021, 16 advanced heart failure patients underwent Impella 5.5 temporary left ventricular assist device support through axillary approach. Subsequently, all these patients had heart transplantation. All patients were either ambulatory or chair bound during their temporary mechanical circulatory support until heart transplantation. Patients were kept on Impella support median of 19 days (3–31) with the median lactate dehydrogenase level of 220 (149–430). All Impella devices were removed during heart transplantation. During Impella support, patients had improved renal function with median creatinine serum level of 1.55 mg/dL decreased to 1.25 (P = 0.007), pulmonary artery pulsatility index scores increased from 2.56 (0.86–10) to 4.2 (1.3–10) (P = 0.048), and right ventricular function improved (P = 0.003). Patients maintained improved renal function and favourable haemodynamics after their heart transplantation as well. All patients survived without any significant morbidity after their heart transplantation. Conclusions Impella 5.5 temporary left ventricular assist device optimizes care of heart transplant recipients providing superior haemodynamic support, mobility, improved renal function, pulmonary haemodynamics, and right ventricular function. Utilizing Impella 5.5 as a direct bridging strategy to heart transplantation resulted in excellent outcomes.
Incidentally Discovered Cor Triatriatum Sinistrum Anomaly During Heart Transplant
Ahmed, Magdy M. El‐Sayed , Makey, Ian A. , Thomas, Mathew , Jacob, Samuel , Landolfo, Kevin , Thomas, Mathew , Landolfo, Kevin P, Pham, Si M. , Thomas, Mathew

Texas Heart Institute Journal | December 6, 2022 | Volume: 49 | Issue: 6 | Pages: No page available

10.14503/thij-20-7453 Get It

Safe heart flush technique during recovery from donors after circulatory death
Ahmed, Magdy M. El‐Sayed , Landolfo, Kevin , Jacob, Samuel , Sareyyüpoğlu, Başar , Thomas, Mathew , Pham, Si M. , Makey, Ian A. , Thomas, Mathew , El-Sayed Ahmed, Magdy M , Landolfo, Kevin P, Thomas, Mathew , Pham, Si

Journal of Cardiac Surgery | October 14, 2022 | Volume: 37 | Issue: 12 | Pages: 5646-5648

10.1111/jocs.17023 Get It

MERGING ADVANCE TECHNOLOGY TO IMPROVE OUTCOMES IN HEART TRANSPLANTATION - A CASE REPORT
Jang, Jin Sung , Pham, S, JM, Ruiz, PC, Patel, JC, Leoni, DS, Yip, JN, Nativi, Landolfo, K, Sareyyupoglu, B, RM, Goswami, Pham, S., Ruiz, Jose , Patel, Parag C. , Leoni, Juan Carlos , Yip, Daniel , Nativí, Jose, Landolfo, Kevin , Sareyyüpoğlu, Başar , Goswami, Rohan

INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH | August 5, 2022 | Volume: No volume available | Issue: No issue available | Pages: 26-28

10.36106/ijsr/5822267 Get It

One of the signicant obstacles to donor heart utilization is that increasingly prolonged cold ischemic times are associated with worsened short- and long-term outcomes. As a result, most transplant centers aim to limit cold ischemic times to less than four hours. The TransMedics Organ Care System (OCS) (Trans Medics, Andover MA) is a portable ex vivo perfusion system designed to store a donor heart in a beating, metabolically active state, until it reaches the recipient, thereby allowing extended time outside the body while minimizing the effects of cold storage. We present a case of a heart transplant recipient supported with the Impella 5.5 as a bridge to transplantation who received a donation after circulatory death (DCD) heart supported by OCS. To our knowledge, this is the rst report of such a case.
Safe Heart Flush Technique During Recovery From Donors After Circulatory Death
Ahmed, Magdy M. El‐Sayed , Landolfo, Kevin, Jacob, Samuel , Sareyyüpoğlu, Başar , Thomas, Mathew , Makey, Ian A. , Landolfo, Kevin , Pham, Si M.

No container title available | June 29, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.165648258.81499266/v1 Get It

For donation after circulatory death, procurement is performed after the heart has arrested. This technique has been employed and adopted by clinicians to overcome the shortage of available hearts for transplant. Warm ischemia time plays a pivotal role in the survival outcome of the heart recipients. We describe a fast and safe technique to flush the heart during recovery from circulatory death donors in order to shorten the warm ischemia time.
P32: Treatment of LVAD drive line infections with absorbable antibiotic beads.
Wadiwala, Ishaq , Alamouti-fard, Emad, Sareyyüpoğlu, Başar , Landolfo, Kevin , Pham, Si M.

ASAIO Journal | June 16, 2022 | Volume: 68 | Issue: Supplement 2 | Pages: 108-108

10.1097/01.mat.0000841344.52757.b8 Get It

REN3: Percutaneous Axillary Temporary Mechanical Support Improves Renal Function Prior To Heart Transplantation In Patients With Chronic Kidney Disease
Jang, Ji-Min, Nativí, Jose, Patel, Parag C. , Leoni, Juan , Yip, Daniel , Sareyyüpoğlu, Başar , Landolfo, Kevin , Leoni, Juan Carlos , Pham, Si M. , Goswami, Rohan

ASAIO Journal | June 16, 2022 | Volume: 68 | Issue: Supplement 2 | Pages: 89-89

10.1097/01.mat.0000841208.11864.3b Get It

Packing the donor heart: Is SherpaPak cold preservation technique safer compared to ice cold storage
Bitargil, Macit , Haddad, Osama , Pham, Si M. , Garg, Neha , Jacob, Samuel , Ahmed, Magdy M. El‐Sayed , Landolfo, Kevin , Patel, Parag C. , Goswami, Rohan , Leoni, Juan , Yip, Daniel , Sareyyüpoğlu, Başar , El-Sayed Ahmed, Magdy M , Goswami, Rohan M , Leoni, Juan Carlos , Yip, Daniel S , Patel, Parag C. , Pham, Si , Garg, Neha , Goswami, Rohan

Clinical Transplantation | May 11, 2022 | Volume: 36 | Issue: 8 | Pages: No page available

10.1111/ctr.14707 Get It

AbstractIntroductionThe present study aimed to compare the clinical outcomes of heart transplant patients whose donor hearts were preserved with the SherpaPak controlled cold organ system versus the conventional ice storage technique.MethodsAll patients undergoing heart transplantation at our center between January 2019 and April 2021 were divided into two groups according to the technique used during donor heart preservation and transport. The first group consisted of 34 SherpaPak controlled temperature preservation patients, and the second group consisted of 47 patients where the conventional three bags and ice technique was utilized during organ transportation. The two groups were compared based on demographics, operative details, and postoperative outcomes.ResultsThere were no significant differences between the groups regarding Vasoactive Inotropic Score (VIS), Primary Graft Dysfunction (PGD), and the need for a transient pacer. However, the VIS, PGD, and pacing trends were lower in the SherpaPak patients even though the total ischemic and cardiopulmonary bypass times were significantly longer. Furthermore, SherpaPak patients exhibited a shorter stay in the ICU with no severe PGD and mortality.ConclusionThe SherpaPak donor heart preservation provides safe outcomes in heart transplant patients. Further research is needed to utilize this method for longer durations of ischemic time and expand travel distances for organ transportation.
Controlled temperatures in cold preservation provides safe heart transplantation results
Bitargil, Macit , Haddad, Osama , Pham, Si M. , Goswami, Rohan , Patel, Parag C. , Jacob, Samuel , Ahmed, Magdy M. El‐Sayed , Leoni, Juan , Yip, Daniel , Landolfo, Kevin , Sareyyüpoğlu, Başar , Goswami, Rohan M, Leoni Moreno, Juan Carlos, Yip, Daniel S, Pham, Si , Goswami, Rohan , Leoni, Juan Carlos

Journal of Cardiac Surgery | January 21, 2022 | Volume: 37 | Issue: 4 | Pages: 732-738

10.1111/jocs.16243 Get It

1131: LOBAR TORSION AFTER BILATERAL LUNG TRANSPLANTATION: RARE COMPLICATION REQUIRING URGENT INTERVENTION
Shah, Sadia , Thomas, Mathew , Landolfo, Kevin , Shah, Sadia , Pham, Si M. , Haddad, Tarik , Shah, Sadia Z.

Critical Care Medicine | December 16, 2021 | Volume: 50 | Issue: 1 | Pages: 564-564