Back to Authors

Cha, Yong‐Mei

https://orcid.org/0000-0002-5897-9464

Mayo Clinic

Mayo Clinic

Citations 164

Incidence of Idiopathic Ventricular Arrhythmias
Sirichand, Surksha , Killu, Ammar M. , Padmanabhan, Deepak , Hodge, David O. , Chamberlain, Alanna M. , Brady, Peter A. , Packer, Douglas L. , Munger, Thomas M. , Shen, Win-Kuang, Cha, Yong‐Mei , Asirvatham, Samuel J. , Friedman, Paul A. , Mulpuru, Siva K. , Kapa, Suraj , Noseworthy, Peter A. , Gersh, Bernard J. , McLeod, Christopher J. , Asirvatham, Samuel J , Chamberlain, Alanna M

Circulation: Arrhythmia and Electrophysiology | February 9, 2017 | Volume: 10 | Issue: 2 | Pages: No page available

10.1161/circep.116.004662 Get It

Background— Ventricular tachycardia and premature ventricular complexes (PVCs) most frequently occur in the context of structural heart disease. However, the burden of idiopathic ventricular arrhythmias (IVA) in the general population is unknown. Methods and Results— We identified incident cases of IVA between 2005 and 2013 from Olmsted County, Minnesota, using the Rochester Epidemiology Project database. For PVC cohorts, we included those with frequent (defined as ≥100 PVC/24 hours) symptomatic PVCs. We defined IVA-associated cardiomyopathy as a drop in ejection fraction of ≥10% from baseline. Between 2005 and 2013, we identified 614 individuals with incident IVA (229 [37.3%] were male; average age was 52.1±17.2 years). Of these, 177 (28.8%) had idiopathic ventricular tachycardia, 408 (66.5%) had symptomatic PVCs, and 29 (4.7%) had IVA-associated cardiomyopathy. The age- and sex-adjusted incidence rates in 2005 to 2007, 2008 to 2010, and 2011 to 2013 were 44.9 per 100 000 (95% confidence interval [CI], 38.0–51.8), 47.6 per 100 000 (95% CI, 40.8–54.5), and 62.0 per 100 000 (95% CI, 54.4–69.6), respectively. In idiopathic ventricular tachycardia, there was an increase in incidence rate with ages ( P <0.001) but not between sexes ( P =0.12). The age-adjusted incidence of symptomatic PVC was higher in females than in males (46.2 per 100 000 [95% CI, 40.9–51.6] versus 20.5 per 100 000 [95% CI, 16.8–24.3]; P <0.001). The small number of individuals with IVA-associated cardiomyopathy precluded any formal testing. Conclusions— The incidence of IVA is increasing. Furthermore, overall incidence increases with age. Although the rate of idiopathic ventricular tachycardia is similar across sexes, women have a higher incidence of symptomatic PVC.
Magnetic Resonance Imaging in Nondependent Pacemaker Patients with Pacemakers and Defibrillators with a Nearly Depleted Battery
Okamura, Hideo , Padmanabhan, Deepak , Watson, Robert E. , Dalzell, Connie, Acker, Nancy, Jondal, Mary Lou, ROMME, ABBY L., Cha, Yong‐Mei , Asirvatham, Samuel J. , Felmlee, Joel P. , Friedman, Paul A. , Jondal, Mary, Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | February 7, 2017 | Volume: 40 | Issue: 5 | Pages: 476-481

10.1111/pace.13042 Get It

BackgroundMagnetic resonance imaging (MRI) in patients with non‐MRI‐conditional cardiac implantable electronic devices (CIEDs) has been shown to be safe when performed under closely monitored protocols. However, the safety of MRI in patients with devices with a nearly depleted battery has not been reported.MethodsProspective data were collected between January 2008 and May 2015 in patients with non‐MRI‐conditional CIEDs undergoing clinically indicated MRI under institutional protocol. Patients who were pacemaker dependent were excluded. Patients whose devices were at elective replacement indicator (ERI) at the time of MRI or close to ERI (ERI or replacement for battery depletion within 3 months of scan) were identified through database review and analyzed for clinical events.ResultsMRI scans (n = 569) were performed in 442 patients. Of these, we identified 13 scans performed with a nearly depleted battery in nine patients. All scans with implantable cardioverter defibrillators (ICDs, n = 9) were uneventful. However, two scans with pacemakers close to ERI resulted in a power‐on‐reset (PoR) event. One scan with a pacemaker close to ERI that was programmed to DOO mode reached ERI during MRI and automatically changed to VVI mode. Additionally, one scan with a pacemaker at ERI did not allow programming. All pacemakers with events were implanted before 2005.ConclusionPatients with pacemakers and ICDs with a nearly depleted battery can safely undergo MRI when patients are not pacemaker dependent. Attention should be paid because old devices can result in PoR or ERI during MRI, which may lead to oversensing and inhibition of pacing.
Impact of a Care Process Model on Management of Cardiovascular Implantable Electronic Device Infections
Anderson, Brenda, Linderbaum, Jane A. , Ziel, Thomas De, Cha, Yong‐Mei , Loomis, Erica, Espinosa, Raúl E. , Friedman, Paul A. , Greason, Kevin L. , Schiller, Henry J., Virk, Abinash , Wilson, Walter R. , Steckelberg, James M., Tan, Eugene M. , Nagpal, Avish , DeSimone, Daniel C. , Li, Zhuo , Sohail, M. Rizwan , Baddour, Larry M.

Open Forum Infectious Diseases | February 3, 2017 | Volume: 3 | Issue: suppl_1 | Pages: No page available

10.1093/ofid/ofw172.811 Get It

Impact of a Primary Inpatient Electrophysiology Service on Cardiovascular Implantable Electronic Device Infections in a Tertiary Care Hospital
Anderson, Brenda, Linderbaum, Jane A. , Ziel, Thomas De, Li, Zhuo, Cha, Yong‐Mei , Loomis, Erica, Espinosa, Raúl E. , Friedman, Paul A. , Greason, Kevin L. , Schiller, Henry J., Virk, Abinash , Wilson, Walter R., Steckelberg, James M., Tan, Eugene M. , Nagpal, Avish , DeSimone, Daniel C. , Sohail, M. Rizwan , Baddour, Larry M.

Open Forum Infectious Diseases | February 2, 2017 | Volume: 3 | Issue: suppl_1 | Pages: No page available

10.1093/ofid/ofw172.810 Get It

The Modulating Effects of Cardiac Resynchronization Therapy on Myocardial Metabolism in Heart Failure
XU, YI‐ZHOU, Chen, Chao-Feng , Gao, Xiaofei , Hua, Wei , Cha, Yong‐Mei , Dzeja, Petras P. , CHEN, BIN

Pacing and Clinical Electrophysiology | November 3, 2016 | Volume: 39 | Issue: 12 | Pages: 1404-1409

10.1111/pace.12971 Get It

Heart failure (HF) is associated with changes in cardiac substrate utilization and energy metabolism, including a decline in high‐energy phosphate content, mitochondrial dysfunction, and phosphotransfer enzyme deficiency. A shift toward glucose metabolism was noted in the end stage of HF in animals, although HF in humans may not be associated with a shift toward predominant glucose utilization. Deficiencies of micronutrients are well‐established causes of cardiomyopathy. Correction of these deficits can improve heart function. The genes governing the energy metabolism were predominantly underexpressed in nonischemic cardiomyopathy and hypertrophic cardiomyopathy but were overexpressed in ischemic cardiomyopathy. Cardiac resynchronization therapy (CRT) has been proven to increase cardiac efficiency without increasing myocardial oxygen consumption. Altered myocardial metabolism is normalized by CRT to improve ventricular function.
Effect of Ventricular Arrhythmia Ablation in Patients With Heart Mate II Left Ventricular Assist Devices: An Evaluation of Ablation Therapy
Snipelisky, David , Reddy, Yogesh N.V. , Manocha, Kevin K. , Patel, Aalok, Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Packer, Douglas L. , Cha, Yong‐Mei , Brady, Peter A. , Maleszewski, Joseph J. , Mulpuru, Siva K. , Manocha, Kevin, Dunlay, Shannon M. , Kapa, Suraj , Noseworthy, Peter A. , Asirvatham, Samuel J , Nishimura, Rick

Journal of Cardiovascular Electrophysiology | October 21, 2016 | Volume: 28 | Issue: 1 | Pages: 68-77

10.1111/jce.13114 Get It

VT Ablation in LVAD RecipientsBackgroundPatients with advanced heart failure (HF) are predisposed to ventricular arrhythmias (VAs), particularly following implantation of a left ventricular assist device (LVAD). There is minimal evidence for appropriate management strategies.ObjectivesThis study aimed to compare the burden of VA and response to ablation performed either before or following LVAD implantation.MethodsWe created a retrospective cohort of patients who underwent both VA ablation and Heart Mate II (Thoratec, Pleasanton, CA, USA) LVAD implantation at Mayo Clinic (Rochester, MN, USA). Patients were stratified based on whether they underwent VA ablation before (pre‐LVAD) or after LVAD (post‐LVAD) implantation. Descriptive analyses assessed 6‐month arrhythmia burden in relation to LVAD implantation and VA ablation.ResultsA total of 9 patients underwent both LVAD implantation and VA ablation. There were 3 and 6 patients, respectively, in the pre‐LVAD and post‐LVAD cohorts. Among patients in the pre‐LVAD cohort, the median number of VAs tended to increase after ablation (9 vs. 72) and decreased after LVAD implantation (72 vs. 63). Similarly among patients in the post‐LVAD cohort, the median burden of VAs increased after LVAD implantation (1 vs. 22) and the median burden decreased after ablation (22 vs. 13). Two of 6 patients had substrate related to the LVAD inflow cannula site, while other substrate was not related directly to the cannula.ConclusionsIn patients with progressive HF and LVAD implantation, ablation is associated with reduced VA rates. In LVAD patients, most VAs arise from substrate unrelated to the inflow cannula site.
Sudden death and its risk factors after atrioventricular junction ablation and pacemaker implantation in patients with atrial fibrillation
Wang, Ruxing , Lee, Hon‐Chi, Li, Jiaping , Hodge, David O. , Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Pavri, Behzad B. , Shen, Win‐Kuang , Srivathsan, Komandoor

Clinical Cardiology | October 17, 2016 | Volume: 40 | Issue: 1 | Pages: 18-25

10.1002/clc.22600 Get It

BackgroundAlthough sudden death (SD) is a rare complication after atrioventricular junction (AVJ) ablation and permanent pacemaker implantation, the risk factors leading to this SD remain unknown. The purpose of this study was to investigate SD and its risk factors after ablate‐and‐pace strategy for rate control in atrial fibrillation (AF) patients during long‐term follow‐up.HypothesisMethodsFrom January 2005 to December 2009, we enrolled into this study 517 AF patients with AVJ ablation and right ventricular pacemaker implantation. Patients were divided into 2 groups, SD and non‐SD. Cox proportional hazards models were used to assess potential risk factors for overall mortality and SD.ResultsDuring a mean follow‐up of 25.8 ± 18.6 months (range, 3 days to 63.8 months), 53 patients died (15 with SD). Cox proportional hazards models showed that the presence of congestive heart failure, New York Heart Association functional class, chronic renal failure, and nonsustained ventricular tachycardia were risk factors that predicted overall mortality. For SD, the presence of dilated cardiomyopathy and mitral stenosis were associated risk factors. SD was exclusively seen in patients who had narrow QRS complex or right bundle branch block prior to AVJ ablation and pacemaker implantation; SD was not seen in any patient with preexisting complete left bundle branch block.ConclusionsDilated cardiomyopathy, mitral stenosis, and baseline QRS morphology should be examined as potential risk factors for SD after AVJ ablation and pacemaker implantation.
Outcomes of Transvenous Lead Extraction for Cardiovascular Implantable Electronic Device Infections in Patients With Prosthetic Heart Valves
Huang, Xin-Miao, Fu, Hai-xia, Zhong, Li , Cao, Jiang, Asirvatham, Samuel J. , Sohail, M. Rizwan , Nishimura, Rick A., Greason, Kevin L. , Suri, Rakesh M. , Friedman, Paul A. , Cha, Yong‐Mei , Baddour, Larry M. , Nkomo, Vuyisile T. , Suri, Rakesh M. , Asirvatham, Samuel J , Sohail, M Rizwan

Circulation: Arrhythmia and Electrophysiology | September 15, 2016 | Volume: 9 | Issue: 9 | Pages: No page available

10.1161/circep.116.004188 Get It

Background— Lead-related or valve-related endocarditis can complicate cardiovascular implantable electronic device (CIED) infection in patients with both CIED and prosthetic valves. The objective of this study was to determine the outcomes of transvenous lead extraction for CIED infection in patients with prosthetic valves. Methods and Results— We retrospectively screened 794 transvenous lead extraction procedures, between September 1, 2001 and August 31, 2012, at Mayo Clinic to identify patients with prosthetic valves who underwent lead extraction for infection. Demographic, clinical, and follow-up characteristics were analyzed. In total, 51 patients (6%) met the study inclusion criteria, of whom 20 had pocket infection and 31 had lead-related or valve-related, or both, endocarditis or bloodstream infection (mean age, 67 [18] years). Staphylococcal species were the most common pathogens, including Staphylococcus aureus in 20 cases (39%) and coagulase-negative staphylococci in 19 cases (37%). Overall, 127 transvenous leads (median lead age, 52 months) were extracted. Of these leads, 123 (97%) were removed completely. The in-hospital mortality rate was 9.8%; no deaths were attributable to the extraction procedure. Ninety-five percent of patients who survived had no evidence of recurrent device-related or valve-related infection. Conclusions— Transvenous lead extraction seems safe and curative in patients with CIED infection and prosthetic valves. Cure of infection can be achieved in the majority of patients with complete CIED removal and antimicrobial therapy and without valve surgery.
Acute Sinus Node Dysfunction after Atrial Ablation: Incidence, Risk Factors, and Management
Killu, Ammar M. , Fender, Erin A. , Deshmukh, Abhishek , Munger, Thomas M. , Araoz, Philip A. , Brady, Peter A. , Cha, Yong‐Mei , Packer, Douglas L. , Friedman, Paul A. , Asirvatham, Samuel J. , Mulpuru, Siva K. , Araoz, Philip, Noseworthy, Peter A. , Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | August 17, 2016 | Volume: 39 | Issue: 10 | Pages: 1116-1125

10.1111/pace.12934 Get It

BackgroundMany patients with atrial fibrillation (AF) or atrial flutter (Aflutter) have concomitant sinus node dysfunction (SND). Ablation may result in injury to the sinus node complex or its blood supply resulting in sinus arrest and need for temporary pacing. We sought to characterize patients who develop acute SND (ASND) during/immediately after AF/Aflutter ablation.MethodsWe performed a retrospective analysis of AF/Aflutter ablation patients between January 1, 2010 and February 28, 2015 to characterize those who required temporary pacemaker (TPM) implantation due to ASND (sinus arrest, sinus bradycardia <40 beats/min, or junctional rhythm with hemodynamic compromise) following atrial ablation.ResultsOf 2,151 patients, eight patients (<0.5%) with ASND manifesting as sinus arrest (n = 2), severe sinus bradycardia (n = 2), and junctional rhythm with hemodynamic compromise (n = 4) were identified (all male, age 66 ± 9.9 years, 4/8 [50%] persistent AF). AF ablation was performed in four, atypical Aflutter in one, and AF/Aflutter in three patients. The ablation set consisted of: pulmonary vein (PV) isolation (n = 6), roof line ablation (n = 6), mitral annulus‐left inferior PV line ablation (n = 5), left atrial appendage‐mitral annulus ablation (n = 1), cavotricuspid isthmus ablation (n = 5), and isolation or ablation near the superior vena cava (SVC, n = 4). Patients with peri‐SVC ablation were more likely to develop ASND (P = 0.03). All patients received TPM; six received permanent pacemaker before discharge, performed 3.5 days postablation (range 2–6 days). At 3‐month device interrogation, all patients were atrially paced >50%.ConclusionASND is a rare complication of atrial ablation. It may be more common when peri‐SVC ablation is performed and may necessitate permanent pacemaker implantation.