Citations 110

Outcomes of Transvenous Lead Extraction for Cardiovascular Implantable Electronic Device Infections in Patients With Prosthetic Heart Valves
Huang, Xin-Miao, Fu, Hai-xia, Zhong, Li , Cao, Jiang, Asirvatham, Samuel J. , Sohail, M. Rizwan , Nishimura, Rick A., Greason, Kevin L. , Suri, Rakesh M. , Friedman, Paul A. , Cha, Yong‐Mei , Baddour, Larry M. , Nkomo, Vuyisile T. , Suri, Rakesh M. , Asirvatham, Samuel J , Sohail, M Rizwan

Circulation: Arrhythmia and Electrophysiology | September 15, 2016 | Volume: 9 | Issue: 9 | Pages: No page available

10.1161/circep.116.004188 Get It

Background— Lead-related or valve-related endocarditis can complicate cardiovascular implantable electronic device (CIED) infection in patients with both CIED and prosthetic valves. The objective of this study was to determine the outcomes of transvenous lead extraction for CIED infection in patients with prosthetic valves. Methods and Results— We retrospectively screened 794 transvenous lead extraction procedures, between September 1, 2001 and August 31, 2012, at Mayo Clinic to identify patients with prosthetic valves who underwent lead extraction for infection. Demographic, clinical, and follow-up characteristics were analyzed. In total, 51 patients (6%) met the study inclusion criteria, of whom 20 had pocket infection and 31 had lead-related or valve-related, or both, endocarditis or bloodstream infection (mean age, 67 [18] years). Staphylococcal species were the most common pathogens, including Staphylococcus aureus in 20 cases (39%) and coagulase-negative staphylococci in 19 cases (37%). Overall, 127 transvenous leads (median lead age, 52 months) were extracted. Of these leads, 123 (97%) were removed completely. The in-hospital mortality rate was 9.8%; no deaths were attributable to the extraction procedure. Ninety-five percent of patients who survived had no evidence of recurrent device-related or valve-related infection. Conclusions— Transvenous lead extraction seems safe and curative in patients with CIED infection and prosthetic valves. Cure of infection can be achieved in the majority of patients with complete CIED removal and antimicrobial therapy and without valve surgery.
Incidence, Treatment Intensity, and Incremental Annual Expenditures for Patients Experiencing a Cardiac Implantable Electronic Device Infection
Sohail, M. Rizwan , Eby, Elizabeth L. , Ryan, Michael P. , Gunnarsson, Candace , Greenspon, Arnold J. , Wright, Laura A, Wright, Laura A. , Sohail, M Rizwan

Circulation: Arrhythmia and Electrophysiology | August 9, 2016 | Volume: 9 | Issue: 8 | Pages: No page available

10.1161/circep.116.003929 Get It

Background— Because of the increasing use of cardiac implantable electronic devices (CIEDs), it is important to estimate the incidence and annual healthcare expenditures associated with CIED infections. Methods and Results— Patients with a record of an initial or replacement (full implant or generator only) CIED implant during the calendar years 2009 to 2012 in MarketScan Commercial Claims and Medicare Supplemental database were identified. CIED infections were classified into 4 categories: (1) infection not managed by inpatient admission nor implant removal, (2) infection managed by inpatient admission but no implant removal, (3) infection managed by an implant removal either in an inpatient or in an outpatient setting, and (4) infection with severe sepsis and managed in an inpatient setting with implant removal. Using separate models for initial and replacement cohorts, annualized incidence of infection and incremental annual expenditures by treatment intensity were estimated. Cumulative incidence of infection at 1 year post implant was 1.18% for initial CIED implants and 2.37% for replacement. Median time to infection was 35 days for initial and 23 days for replacement. Incremental healthcare expenditures by treatment intensity categories for initial implant patients at 1 year were $16 651, $104 077, $45 291, and $279 744. For replacement patients, incremental expenditures at 1 year by treatment intensity categories were $26 857, $43 541, $48 759, and $362 606. Conclusions— The management of CIED infections results in a substantial healthcare burden with a significant increase in annual expenditures the year after implant when device infection occurs.
Cardiovascular Implantable Electronic Device Infections due toPropionibacteriumSpecies
Rafei, Abdelghani El , Sohail, M. Rizwan , Steckelberg, James M., Wilson, Walter R. , El Rafei, Abdelghani, DeSimone, Daniel C. , DeSimone, Christopher V. , Baddour, Larry M. , Sohail, M Rizwan

Pacing and Clinical Electrophysiology | March 12, 2016 | Volume: 39 | Issue: 6 | Pages: 522-530

10.1111/pace.12845 Get It

Gastrointestinal mucormycosis in immunocompromised hosts
Dioverti, M. Veronica , Abidi, Maheen Z. , Sohail, M. Rizwan , Walker, Randall C., Osmon, Douglas R. , Cawcutt, Kelly A., Cawcutt, Kelly , Sohail, M Rizwan , Abidi, Maheen Z , Dioverti, Maria Veronica , Abidi, Maheen Z

Mycoses | October 12, 2015 | Volume: 58 | Issue: 12 | Pages: 714-718

10.1111/myc.12419 Get It

SummaryInvasive mucormycosis is a rare fungal infection in immunocompromised hosts, but it carries a high mortality rate. Primary gastrointestinal disease is the least frequent form of presentation. Early diagnosis and treatment are critical in the management; however, symptoms are typically non‐specific in gastrointestinal disease, leading to delayed therapy. To describe the clinical presentation, diagnosis, treatment and outcomes of gastrointestinal mucormycosis in immunocompromised hosts, we reviewed all cases of primary gastrointestinal mucormycosis in immunocompromised hosts reported in English literature as well as in our Institution from January 1st 1991 to December 31st 2013 for a total of 31 patients. About 52% of patients underwent solid organ transplant (SOT), while the rest had an underlying haematologic malignancy. Abdominal pain was the most common presenting symptom, followed by gastrointestinal bleeding and fever. Gastric disease was more common in SOT, whereas those with haematologic malignancy presented with intestinal disease (P = 0.002). Although gastrointestinal mucormycosis remains an uncommon condition in immunocompromised hosts, it carries significant morbidity and mortality, particularly in cases with intestinal involvement. A high index of suspicion is of utmost importance to institute early and appropriate therapy and improve outcomes.
Outcomes and Complications of Lead Removal: Can We Establish a Risk Stratification Schema for a Collaborative and Effective Approach?
Fu, Hai‐Xia , Huang, Xinmiao, Li, Zhong , Osborn, Michael J., Asirvatham, Samuel J. , Espinosa, Raúl E. , Brady, Peter A. , Lee, Hon-Chi , Greason, Kevin L. , Sohail, M. Rizwan , Acker, Nancy G., Hodge, David O. , Friedman, Paul A. , Cha, Yong‐Mei , Sohail, Rizwan M., Baddour, Larry M. , Asirvatham, Samuel J , Sohail, M Rizwan

Pacing and Clinical Electrophysiology | August 21, 2015 | Volume: 38 | Issue: 12 | Pages: 1439-1447

10.1111/pace.12736 Get It

Predicting Risk of Endovascular Device Infection in Patients With Staphylococcus aureus Bacteremia (PREDICT-SAB)
Sohail, M. Rizwan , Palraj, Bharath Raj, Uslan, Daniel Z. , Al‐Saffar, Farah , Friedman, Paul A. , Hayes, David L. , Lohse, Christine M. , Wilson, Walter R. , Steckelberg, James M., Palraj, Raj , Khalid, Sana , Al-Saffar, Farah, Khalid, Sana , Baddour, Larry M. , Sohail, M Rizwan , Palraj, Raj

Circulation: Arrhythmia and Electrophysiology | December 12, 2014 | Volume: 8 | Issue: 1 | Pages: 137-144

10.1161/circep.114.002199 Get It

Background— Prompt recognition of underlying cardiovascular implantable electronic device (CIED) infection in patients presenting with Staphylococcus aureus bacteremia (SAB) is critical for optimal management of these cases. The goal of this study was to identify clinical predictors of CIED infection in patients presenting with SAB and no signs of pocket infection. Methods and Results— All cases of SAB in CIED recipients at Mayo Clinic from 2001 to 2011 were retrospectively reviewed. We identified 131 patients with CIED who presented with SAB and had no clinical signs of device pocket infection. Forty-five (34%) of these patients had underlying CIED infection based on clinical or echocardiographic criteria. The presence of a permanent pacemaker rather than an implantable cardioverter-defibrillator (odds ratio, 3.90; 95% confidence interval, 1.65–9.23; P =0.002), >1 device-related procedure (odds ratio, 3.30; 95% confidence interval, 1.23–8.86; P =0.018), and duration of SAB ≥4 days (odds ratio, 5.54; 95% confidence interval, 3.32–13.23; P <0.001) were independently associated with an increased risk of CIED infection in a multivariable model. The area under the receiver operating characteristics curve for the multivariable model was 0.79, indicating a good discriminatory capacity to distinguish SAB patients with and without CIED infection. Conclusions— Among patients presenting with SAB and no signs of pocket infection, the risk of underlying CIED infection can be calculated based on the type of device, number of device-related procedures, and duration of SAB. We propose that patients without any of these high-risk features have a low risk of underlying CIED infection and may be monitored closely without immediate device extraction. Prospective studies are needed to validate this risk prediction model.
Increased Long‐Term Mortality in Patients with Cardiovascular Implantable Electronic Device Infections
Sohail, M. Rizwan , Braid‐Forbes, Mary Jo, Forbes, Kevin F. , Lerner, Daniel J., Rizwan Sohail, Muhammad, Henrikson, Charles A. , Sohail, M Rizwan

Pacing and Clinical Electrophysiology | September 22, 2014 | Volume: 38 | Issue: 2 | Pages: 231-239

10.1111/pace.12518 Get It

BackgroundDevice infection is associated with increased mortality in patients receiving cardiovascular implantable electronic device (CIED) therapy. However, long‐term mortality associated with CIED infections has not been systematically analyzed in larger studies. This study sought to determine the long‐term mortality associated with CIED infection in a large cohort of Medicare beneficiaries.MethodsWe used a retrospective study design to analyze 3‐year mortality in 200,219 Medicare fee‐for‐service patients admitted for CIED generator implantation, replacement, or revision between January 1, 2007 and December 31, 2007. Multivariate analysis adjusting for age, sex, race, and 28 comorbidities was performed to determine the relative risk (RR) of death in the 12 quarters following CIED infection.ResultsPatients with CIED infection, compared to device recipients without infection, had increased mortality that persisted for at least 3 years after the admission quarter for all device types: pacemakers (PMs: 53.8% vs 33%; P < 0.001), implantable cardioverter defibrillator (ICD: 47.7% vs 31.6%; P < 0.001), and cardiac resynchronization therapy‐defibrillator (CRT‐D: 50.8% vs 36.5%; P < 0.001). After adjusting for patient demographics and comorbidities, significantly increased RR of death following CIED infection persisted for at least 3 years following PM infection, and for at least 2 years with single‐ and dual‐chamber ICD infection.ConclusionsCIED recipients who develop device infection have increased, device‐dependent, long‐term mortality even after successful treatment of infection. The etiology of this persistent increased risk of death associated with CIED infection is unknown and merits further investigation.
Stability in the cumulative incidence, severity and mortality of 101 cases of invasive mucormycosis in high‐risk patients from 1995 to 2011: a comparison of eras immediately before and after the availability of voriconazole and echinocandin‐amphotericin co
Abidi, Maheen Z. , Sohail, M. Rizwan , Wilhelm, Mark , Wengenack, Nancy L. , Brumble, Lisa , Shah, Harshal , Hata, D. Jane , McCullough, Ann E. , Wendel, Amy J., Vikram, Holenarasipur R. , Kusne, Shimon , Litzow, Mark R. , Letendre, Louis, Lahr, Brian D. , Poeschla, Eric M. , Walker, Randall C., Cummins, Nathan W. , Vikram, Holenarasipur R. , Sohail, M Rizwan , Abidi, Maheen Z , Abidi, Maheen Z

Mycoses | July 18, 2014 | Volume: 57 | Issue: 11 | Pages: 687-698

10.1111/myc.12222 Get It

SummaryAs invasive mucormycosis (IM) numbers rise, clinicians suspect prior voriconazole worsens IM incidence and severity, and believe combination anti‐fungal therapy improves IM survival. To compare the cumulative incidence (CI), severity and mortality of IM in eras immediately before and after the commercial availability of voriconazole all IM cases from 1995 to 2011 were analysed across four risk‐groups (hematologic/oncologic malignancy (H/O), stem cell transplantation (SCT), solid organ transplantation (SOT) and other), and two eras, E1 (1995–2003) and E2, (2004–2011). Of 101 IM cases, (79 proven, 22 probable): 30 were in E1 (3.3/year) and 71 in E2 (8.9/year). Between eras, the proportion with H/O or SCT rose from 47% to 73%, while ‘other’ dropped from 33% to 11% (P = 0.036). Between eras, the CI of IM did not significantly increase in SCT (P = 0.27) or SOT (P = 0.30), and patterns of anatomic location (P = 0.122) and surgical debridement (P = 0.200) were similar. Significantly more patients received amphotericin‐echinocandin combination therapy in E2 (31% vs. 5%, P = 0.01); however, 90‐day survival did not improve (54% vs. 59%, P = 0.67). Since 2003, the rise of IM reflects increasing numbers at risk, not prior use of voriconazole. Frequent combination of anti‐fungal therapy has not improved survival.
Acute renal failure associated with albendazole therapy in a patient with trichinosis
Batzlaff, Cassandra M., Pupaibool, Jakrapun , Sohail, M. Rizwan , Batzlaff, Cassandra Marie, Sohail, M Rizwan , Pupaibool, Jakrapun

BMJ Case Reports | May 19, 2014 | Volume: 2014 | Issue: No issue available | Pages: bcr2013200668

10.1136/bcr-2013-200668 Get It

A 72-year-old Caucasian woman presented with a 3-week history of confusion, cramping abdominal pain, nausea, vomiting, diarrhoea, fatigue and dehydration. By history, she reported consumption of raw pork and bacon that was salted and cured in brine, but not boiled or cooked. Laboratory testing was significant for an absolute eosinophil count of 3.09×109/L. She was found to have a positive Trichinella serology by ELISA testing. Based on history of raw pork consumption, symptoms, peripheral eosinophilia and positive serology, a diagnosis of trichinosis was made. Treatment was started with oral albendazole. Following initiation of therapy, the patient developed acute kidney injury presumably secondary to albendazole. Therapy was discontinued. Her serum creatinine returned to baseline over the following days. The decision was made to proceed with observation alone, as she did not tolerate treatment. At the 3-week follow-up, her gastrointestinal symptoms had improved and her eosinophilia had resolved.
Variability in Clinical Features of Early Versus Late Cardiovascular Implantable Electronic Device Pocket Infections
Welch, M P, Uslan, Daniel Z. , Greenspon, Arnold J. , Sohail, M. Rizwan , Blank, Elisabeth, Carrillo, Roger G. , Danik, Stephan B., Lechuga, Ana del Río , Hellinger, Walter C. , Le, Katherine, Naber, Christoph, Peacock, James E. , Vikram, Holenarasipur R. , Tseng, Chi‐Hong , Prutkin, Jordan M. , Investigators, for the MEDIC, Baddour, Larry M. , Miró, José María , Vikram, Holenarasipur R. , Investigators, for the MEDIC, Sohail, M Rizwan

Pacing and Clinical Electrophysiology | March 25, 2014 | Volume: 37 | Issue: 8 | Pages: 955-962

10.1111/pace.12385 Get It

Background Cardiovascular implantable electronic device (CIED) pocket infections are often related to recent CIED placement or manipulation, but these infections are not well characterized. The clinical presentation of CIED pocket infection, based on temporal onset related to last CIED procedure, deserves further study. Methods The MEDIC (Multicenter Electrophysiologic Device Infection Cohort) prospectively enrolled subjects with CIED infection. Subjects were stratified into those whose infection occurred <12 months (early) or ≥12 months (late) since their last CIED‐related procedure. Results There were 132 subjects in the early group and 106 in the late group. There were more females (P = 0.009) and anticoagulation use (P = 0.039) in the early group. Subjects with early infections were more likely to have had a generator change or lead addition as their last procedure (P = 0.03) and had more prior CIED procedures (P = 0.023). Early infections were more likely to present with pocket erythema (P < 0.001), swelling (P < 0.001), and pain (P = 0.007). Late infections were more likely to have pocket erosion (P = 0.005) and valvular vegetations (P = 0.009). In bacteremic subjects, early infections were more likely healthcare‐associated (P < 0.001). In‐hospital and 6‐month mortality were equivalent. Conclusion A total of 45% of patients with CIED pocket infection presented >12 months following their last CIED‐related procedure. Patients with early infection were more likely to be female, on anticoagulation, and present with localized inflammation, whereas those with late infection were more likely to have CIED erosion or valvular endocarditis.