Abstract Context. —Monitoring customer satisfaction is a valuable component of a laboratory quality improvement program. Objective. —To survey the level of physician satisfaction with hospital clinical laboratory services. Design. —Participating institutions provided demographic and practice information and survey results of physician satisfaction with defined aspects of clinical laboratory services, rated on a scale of 1 (poor) to 5 (excellent). Results. —One hundred thirty-eight institutions participated in this study and submitted a total of 4329 physician surveys. The overall satisfaction score for all institutions ranged from 2.9 to 5.0. The median overall score for all participants was 4.1 (10th percentile, 3.6; 90th percentile, 4.5). Physicians were most satisfied with the quality/reliability of results and staff courtesy, with median values of excellent or good ratings of 89.9%. Of the 5 service categories that received the lowest percentage values of excellent/good ratings (combined scores of 4 and 5), 4 were related to turnaround time for inpatient stat, outpatient stat, routine, and esoteric tests. Surveys from half of the participating laboratories reported that 96% to 100% of physicians would recommend the laboratory to other physicians. The category most frequently selected as the most important category of laboratory services was quality/reliability of results (31.7%). Conclusions. —There continues to be a high level of physician satisfaction and loyalty with clinical laboratory services. Test turnaround times are persistent categories of dissatisfaction and present opportunities for improvement.
Continuous Monitoring of Stat and Routine Outlier Turnaround Times: Two College of American Pathologists Q-Tracks Monitors in 291 Hospitals
Abstract Context. —The laboratory test turnaround times (TATs) that exceed the expectations of clinicians who order those tests, the so-called outlier test reporting rates, may be responsible for perceptions of inadequate laboratory service. Objective. —To monitor outlier test reporting rates for emergency department stat potassium results and routine inpatient morning blood tests. Design. —In 2 different monitors, each conducted for 2 years, laboratory personnel in institutions enrolled in the College of American Pathologists (CAP) Q-Tracks program tracked the percentages of emergency department stat potassium results and/or the percentages of morning rounds routine test results that were reported later than self-imposed reporting deadlines. Setting. —A total of 291 hospitals participating in 2 CAP Q-Tracks monitors. Results. —Participants monitored 225 140 stat emergency department potassium TATs, of which 33 402 (14.8%) were outliers, and 1 055 040 routine morning test reporting times, of which 123 554 (11.7%) were outliers. For both monitors, there was a significant ( P < .05) downward trend in the outlier rates as the number of quarters in which participants submitted data increased. Conclusion. —Outlier reporting rates for emergency department stat potassium and routine morning test results decreased during the 2-year period of continuous monitoring. The CAP Q-Tracks program provides an effective vehicle by which providers of laboratory services may improve the timeliness with which they deliver the results of laboratory tests.
Biochemical Markers of Myocardial Injury Test Turnaround Time: A College of American Pathologists Q-Probes Study of 7020 Troponin and 4368 Creatine Kinase–MB Determinations in 159 Institutions
Abstract Context. —Rapid diagnosis of acute myocardial infarction in patients presenting to emergency departments (EDs) with chest pain may determine the types, and predict the outcomes of, the therapy those patients receive. The amount of time consumed in establishing diagnoses of acute myocardial infarction may depend in part on that consumed in the generation of the blood test results measuring myocardial injury. Objective. —To determine the normative rates of turnaround time (TAT) for biochemical markers of myocardial injury and to examine hospital and laboratory practices associated with faster TATs. Design. —Laboratory personnel in institutions enrolled in the College of American Pathologists Q-Probes Program measured the order-to-report TATs for serum creatine kinase–MB and/or serum troponin (I or T) for patients presenting to their hospital EDs with symptoms of acute myocardial infarction. Laboratory personnel also completed detailed questionnaires characterizing their laboratories' and hospitals' practices related to testing for biochemical markers of myocardial injury. ED physicians completed questionnaires indicating their satisfaction with testing for biochemical markers of myocardial injury in their hospitals. Setting. —A total of 159 hospitals, predominantly located in the United States, participating in the College of American Pathologists Q-Probes Program. Results. —Most (82%) laboratory participants indicated that they believed a reasonable order-to-report TATs for biochemical markers of myocardial injury to be 60 minutes or less. Most (75%) of the 1352 ED physicians who completed satisfaction questionnaires believed that the results of tests measuring myocardial injury should be reported back to them in 45 minutes or less, measured from the time that they ordered those tests. Participants submitted TAT data for 7020 troponin and 4368 creatine kinase–MB determinations. On average, they reported 90% of myocardial injury marker results in slightly more than 90 minutes measured from the time that those tests were ordered. Among the fastest performing 25% of participants (75th percentile and above), median order-to-report troponin and creatine kinase–MB TATs were equal to 50 and 48.3 minutes or less, respectively. Shorter troponin TATs were associated with performing cardiac marker studies in EDs or other peripheral laboratories compared to (1) performing tests in central hospital laboratories, and (2) having cardiac marker specimens obtained by laboratory rather than by nonlaboratory personnel. Conclusion. —The TAT expectations of the ED physicians using the results of laboratory tests measuring myocardial injury exceed those of the laboratory personnel providing the results of those tests. The actual TATs of myocardial injury testing meet the expectations of neither the providers of those tests nor the users of those test results. Improving TAT performance will require that the providers and users of laboratory services work together to develop standards that meet the needs of the medical staff and that are reasonably achievable by laboratory personnel.
Abstract Objective. —To determine the frequency with which solitary blood culture samples were submitted to laboratories serving small hospitals and to ascertain whether certain hospital practices relating to the performance of blood cultures were associated with lower solitary blood culture rates (SBCRs). Design. —Participants in the College of American Pathologists Q-Probes laboratory quality improvement program collected data prospectively on the numbers of solitary blood culture sets from adult patients submitted to their laboratories and answered questions about their institutions' practice characteristics relating to the collection of blood culture specimens. Setting and Participants. —Three hundred thirty-three public and private institutions with a median occupied bed size of 57. Participants were located in the United States (n = 329), Canada (n = 3), and Australia (n = 1). Main Outcome Measure. —The solitary blood culture rate was defined as the number of instances in which only 1 blood culture venipuncture was performed on an individual patient during a 24-hour period divided by the total number of blood culture venipunctures that were performed during the study period. Results. —Participants submitted data on 132 778 adult patient blood culture sets. The SBCRs were 3.4% or less in the top-performing 10% of participating institutions (90th percentile and above), 12.7% in the midrange of participating institutions (50th percentile), and 42.5% or more in the bottom-performing 10% of participating institutions (10th percentile and below). In half the participating institutions, the SBCRs for inpatients were 8.3% or less and for outpatients, 22% or less. Solitary blood culture rates were lower for institutions in which phlebotomists rather than nonphlebotomists routinely collected blood culture specimens, in which internal policies required drawing at least 2 blood culture sets, in which hospital personnel contacted clinicians when their laboratories received requests for solitary blood culture sets, and in which quality control programs monitored SBCRs routinely. Conclusions. —Hospitals can achieve SBCRs under 5%. Those hospitals with particularly high SBCRs may lower their rates by altering certain institutional practices.