Abstract Context. —The laboratory test turnaround times (TATs) that exceed the expectations of clinicians who order those tests, the so-called outlier test reporting rates, may be responsible for perceptions of inadequate laboratory service. Objective. —To monitor outlier test reporting rates for emergency department stat potassium results and routine inpatient morning blood tests. Design. —In 2 different monitors, each conducted for 2 years, laboratory personnel in institutions enrolled in the College of American Pathologists (CAP) Q-Tracks program tracked the percentages of emergency department stat potassium results and/or the percentages of morning rounds routine test results that were reported later than self-imposed reporting deadlines. Setting. —A total of 291 hospitals participating in 2 CAP Q-Tracks monitors. Results. —Participants monitored 225 140 stat emergency department potassium TATs, of which 33 402 (14.8%) were outliers, and 1 055 040 routine morning test reporting times, of which 123 554 (11.7%) were outliers. For both monitors, there was a significant ( P < .05) downward trend in the outlier rates as the number of quarters in which participants submitted data increased. Conclusion. —Outlier reporting rates for emergency department stat potassium and routine morning test results decreased during the 2-year period of continuous monitoring. The CAP Q-Tracks program provides an effective vehicle by which providers of laboratory services may improve the timeliness with which they deliver the results of laboratory tests.
Biochemical Markers of Myocardial Injury Test Turnaround Time: A College of American Pathologists Q-Probes Study of 7020 Troponin and 4368 Creatine Kinase–MB Determinations in 159 Institutions
Abstract Context. —Rapid diagnosis of acute myocardial infarction in patients presenting to emergency departments (EDs) with chest pain may determine the types, and predict the outcomes of, the therapy those patients receive. The amount of time consumed in establishing diagnoses of acute myocardial infarction may depend in part on that consumed in the generation of the blood test results measuring myocardial injury. Objective. —To determine the normative rates of turnaround time (TAT) for biochemical markers of myocardial injury and to examine hospital and laboratory practices associated with faster TATs. Design. —Laboratory personnel in institutions enrolled in the College of American Pathologists Q-Probes Program measured the order-to-report TATs for serum creatine kinase–MB and/or serum troponin (I or T) for patients presenting to their hospital EDs with symptoms of acute myocardial infarction. Laboratory personnel also completed detailed questionnaires characterizing their laboratories' and hospitals' practices related to testing for biochemical markers of myocardial injury. ED physicians completed questionnaires indicating their satisfaction with testing for biochemical markers of myocardial injury in their hospitals. Setting. —A total of 159 hospitals, predominantly located in the United States, participating in the College of American Pathologists Q-Probes Program. Results. —Most (82%) laboratory participants indicated that they believed a reasonable order-to-report TATs for biochemical markers of myocardial injury to be 60 minutes or less. Most (75%) of the 1352 ED physicians who completed satisfaction questionnaires believed that the results of tests measuring myocardial injury should be reported back to them in 45 minutes or less, measured from the time that they ordered those tests. Participants submitted TAT data for 7020 troponin and 4368 creatine kinase–MB determinations. On average, they reported 90% of myocardial injury marker results in slightly more than 90 minutes measured from the time that those tests were ordered. Among the fastest performing 25% of participants (75th percentile and above), median order-to-report troponin and creatine kinase–MB TATs were equal to 50 and 48.3 minutes or less, respectively. Shorter troponin TATs were associated with performing cardiac marker studies in EDs or other peripheral laboratories compared to (1) performing tests in central hospital laboratories, and (2) having cardiac marker specimens obtained by laboratory rather than by nonlaboratory personnel. Conclusion. —The TAT expectations of the ED physicians using the results of laboratory tests measuring myocardial injury exceed those of the laboratory personnel providing the results of those tests. The actual TATs of myocardial injury testing meet the expectations of neither the providers of those tests nor the users of those test results. Improving TAT performance will require that the providers and users of laboratory services work together to develop standards that meet the needs of the medical staff and that are reasonably achievable by laboratory personnel.
Outpatient Phlebotomy Success and Reasons for Specimen Rejection
Abstract Objectives.—To determine the rate with which blood collection is successful on the initial phlebotomy encounter, the rate with which laboratory personnel judge specimens unsuitable for analysis, and the practice characteristics associated with fewer unsuccessful collections and fewer rejected specimens. Design.—Clinical laboratories participating in the College of American Pathologists Q-Probes laboratory improvement program prospectively characterized the outcome of outpatient phlebotomies for 3 months or until 20 unsuccessful phlebotomy encounters occurred. By questionnaire, participants provided information about test ordering, patient preparation, and specimen collection. Setting and Participants.—Institutions in the United States (n = 202), Canada (n = 4), Australia (n = 3), and South Korea (n = 1). Main Outcome Measures.—Percentage of successful encounters and percentage of unsuitable specimens. Results.—Of 833289 encounters, 829723 were successful. Phlebotomies were unsuccessful because patients were not fasting as directed (32.2%), phlebotomy orders were missing information (22.5%), patients specimens were difficult to draw (13.0%), patients left the collection area before specimens were collected (11.8%), patients were improperly prepared for reasons other than fasting (6.3%), patients presented at the wrong time (3.1%), or for other reasons (11.8%). Only 2153 specimens (0.3%) were unsuitable; these samples were hemolyzed (18.1%), of insufficient quantity (16.0%), clotted (13.4%), lost or not received in the laboratory (11.5%), inadequately labeled (5.8%), at variance with previous or expected results (4.8%), or unacceptable for other reasons (31.1%). Facilities staffed by laboratory-administered phlebotomists reported higher success rates than facilities staffed by nonlaboratory-administered phlebotomists (P = .002). Conclusions.—Most outpatient phlebotomy encounters are successful and result in specimens suitable for laboratory analysis.
Abstract Objectives.—To establish the rates with which reference laboratories resolve inquiries telephoned to them from primary laboratories and to identify reference laboratory practices associated with higher rates of inquiry resolution. Design and Participants.—For 2 months, or until 50 contacts had occurred, 545 primary laboratories participating in the College of American Pathologists Q-Probes laboratory quality improvement program prospectively documented and characterized telephone inquiries they made to a reference laboratory of their choice. Participants also cataloged their own laboratory's demographic and practice characteristics and their reference laboratory's customer service characteristics. Main Outcome Measure.—Rates with which reference laboratories resolved telephone inquiries. Results.—Participants characterized 11 031 (78.7%) of 14 017 telephone inquiries as resolved by the reference laboratories. Ranked according to inquiry resolution rates, primary laboratories in the 90th percentile characterized reference laboratories as resolving 100% of their inquiries; those in the 10th percentile characterized reference laboratories as resolving only 54.2% of their inquiries. The rate of resolved inquiries was significantly higher (P = .0047) for participants using reference laboratories with 24-hour customer service than it was for participants using reference laboratories with less than 24-hour service. Most primary laboratories (80.9%) chose to monitor 1 of 11 national reference laboratories; in this subset, median rates of inquiry resolution ranged from 90.2% to 55.0% (P < .0001), despite no significant variation in other measured customer service characteristics. Conclusions.—Primary laboratories experience significant differences in the rates with which reference laboratories resolve telephone inquiries. The performance benchmark for reference laboratories is resolution of at least 90% of telephone inquiries from primary laboratory customers.
Abstract Objective. —To determine the frequency with which solitary blood culture samples were submitted to laboratories serving small hospitals and to ascertain whether certain hospital practices relating to the performance of blood cultures were associated with lower solitary blood culture rates (SBCRs). Design. —Participants in the College of American Pathologists Q-Probes laboratory quality improvement program collected data prospectively on the numbers of solitary blood culture sets from adult patients submitted to their laboratories and answered questions about their institutions' practice characteristics relating to the collection of blood culture specimens. Setting and Participants. —Three hundred thirty-three public and private institutions with a median occupied bed size of 57. Participants were located in the United States (n = 329), Canada (n = 3), and Australia (n = 1). Main Outcome Measure. —The solitary blood culture rate was defined as the number of instances in which only 1 blood culture venipuncture was performed on an individual patient during a 24-hour period divided by the total number of blood culture venipunctures that were performed during the study period. Results. —Participants submitted data on 132 778 adult patient blood culture sets. The SBCRs were 3.4% or less in the top-performing 10% of participating institutions (90th percentile and above), 12.7% in the midrange of participating institutions (50th percentile), and 42.5% or more in the bottom-performing 10% of participating institutions (10th percentile and below). In half the participating institutions, the SBCRs for inpatients were 8.3% or less and for outpatients, 22% or less. Solitary blood culture rates were lower for institutions in which phlebotomists rather than nonphlebotomists routinely collected blood culture specimens, in which internal policies required drawing at least 2 blood culture sets, in which hospital personnel contacted clinicians when their laboratories received requests for solitary blood culture sets, and in which quality control programs monitored SBCRs routinely. Conclusions. —Hospitals can achieve SBCRs under 5%. Those hospitals with particularly high SBCRs may lower their rates by altering certain institutional practices.
Abstract Objectives. —To determine the success with which laboratories were able to report morning test results on time, the laboratory practice characteristics associated with improved success, and the degree of satisfaction among clinicians with the timeliness of laboratory service. Design. —Hospital laboratories participating in the College of American Pathologist Q-Probes laboratory quality improvement program prospectively calculated the percentages of morning-run complete blood cell count (CBC) and electrolyte results that were reported on or before predetermined reporting deadlines, completed questionnaires concerning their departments' practice characteristics as they related to performing morning blood work, and distributed to physician utilizers of morning laboratory services questionnaires evaluating physician satisfaction with laboratory services. Setting and Participants. —A total of 367 public and private institutions located in the United States (355), Canada (5), Australia (2), and 1 each in the United Kingdom, Spain, Brazil, Korea, and Guam. Main Outcome Measure. —The percentages of morning-run CBC and electrolyte results reported on or before predetermined reporting deadlines. Results. —Participants submitted data on 40 256 CBC and 39 604 electrolyte specimens. In aggregate, a total of 88.9% of these tests (90.2% of CBCs and 87.6% of electrolytes) were reported on or before the reporting deadlines that the participating laboratories set for themselves. Half of the participants reported 94.6% of their CBC results and 95.5% of their electrolyte results on or before their self-imposed reporting deadlines. No specific demographic features or departmental practice characteristics were associated with higher or lower rates of institutional reporting compliance. Most physician utilizers of early-morning laboratory test results believed that the laboratory is sensitive to and meets the needs of clinicians for timely reporting of early-morning test results. Conclusions. —Most laboratories are capable of reporting 95% of their routine morning laboratory tests on time, and most physicians are satisfied with their laboratories' morning testing service.