Back to Authors

Abraham, Adam C.

https://orcid.org/0000-0003-2131-5178

Mayo Clinic

Colorado State University

Citations 2

Internal Pressure of the Human Meniscal Attachments During Physiological and Pathological Loading
Abraham, Adam C. , Kaufman, Kenton R. , Donahue, Tammy L. Haut , Kaufman, Kenton R

ASME 2012 Summer Bioengineering Conference, Parts A and B | July 19, 2013 | Volume: No volume available | Issue: No issue available | Pages: 451-452

10.1115/sbc2012-80742 Get It

Knee menisci are semi-lunar, fibrocartilaginous structures that convert applied compressive loads to circumferential hoop stresses which are attenuated at the tibial plateau via the meniscal attachments [1]. These specialized interfaces, located at the lateral anterior (LA), lateral posterior (LP), medial anterior (MA), and medial posterior (MP) horns, are crucial to maintaining mechanical functionality of menisci, thereby preventing osteoarthritis [2]. Soft-tissues subjected to compression and shear loads are known to possess proteoglycans, which aid in resisting these applied stresses by retaining interstitial fluid [1]. Interestingly, proteoglycans are also known to be present at the meniscus to bone interface [3]. Despite the presence of these biphasic attachments and their important role in joint load transfer, there have been no quantitative investigations of the mechanical environment within these attachments under physiological and pathological loads. Recent development of a novel pressure microsensor now allows direct observation of fluid pressure, which will aid in understanding the internal mechanical environment within the attachment sites. Previous work indicates that the attachment sites are geometrically, mechanically, and histologically different [4], thus it is hypothesized that the fluid pressures would likewise differ.
Internal pressure of human meniscal root attachments during loading
Abraham, Adam C. , Villegas, Diego F. , Kaufman, Kenton R. , Donahue, Tammy L. Haut , Kaufman, Kenton R

Journal of Orthopaedic Research | June 17, 2013 | Volume: 31 | Issue: 10 | Pages: 1507-1513

10.1002/jor.22408 Get It

ABSTRACTThis study investigated the internal fluid pressure of human cadaver meniscal root attachments. A pressure micro‐sensor was implanted inside each attachment site. Tibiofemoral joints were compressed to 2× body weight at various flexion angles and pressure recorded for 20 min. The anterior cruciate ligament (ACL) was then transected and joints retested. Lastly, a longitudinal incision of the lateral posterior (LP) horn was made and the joint retested. Ramp pressure was defined as the pressure when 2× body weight was reached, and equilibrium pressure was recorded at the end of the hold period. The medial posterior (MP) attachment was subjected to greater ramp pressure than the medial anterior (p = 0.002) and greater equilibrium pressure than all other root attachment sites (p < 0.001). Flexion angle had a significant effect on pressure as full extension was greatest at ramp (p = 0.040). Transection of the ACL decreased ramp pressure in the LP attachment (p = 0.025) and increased equilibrium pressure (p = 0.031) in the MP attachment. The results suggest that repair strategies should be developed which reconstruct the MP attachments to be sufficient to withstand large pressures. Furthermore, since meniscal pressure is highest at full extension, this fact should be considered when prescribing rehabilitation following repair of an attachment. © 2013 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 31:1507–1513, 2013