Back to Authors

McColl, Roderick W.

0000-0001-7022-100X

Mayo Clinic

The University of Texas Southwestern Medical Center

Citations 2

Artificial intelligence-enabled cardiac volumetry for opportunistic screening of cardiomegaly on chest CT: clinical validation with echocardiography
Fan, Christopher , Scanio, Angelo , Yokoo, Patrícia , Wiessman, Maya , Lewis, Matthew A. , Xi, Yin, Duan, Xinhui, McColl, Roderick M, Kay, Fernando Uliana , Fan, Christopher M , Abbara, Suhny , Kay, Fernando , Long, Michael, Duan, Xinhui , McColl, Roderick W. , Peshock, Ronald M.

Radiology Advances | March 3, 2026 | Volume: 3 | Issue: 2 | Pages: No page available

10.1093/radadv/umag013 Get It

Abstract Background Cardiomegaly is a clinically significant incidental finding on chest computed tomography (CT) associated with heart failure, arrhythmias, and sudden cardiac death. Qualitative radiologist assessment is variable, and automated AI tools may enable objective opportunistic cardiac volumetry. Purpose To evaluate whether AI-enabled total cardiac volume (TCVAI) derived from non-ECG-gated, non-contrast chest CT can identify cardiomegaly as defined by echocardiography. Materials and Methods This retrospective study included 307 consecutive patients (median age, 67 years; 56% male) who underwent non-contrast chest CT at a single center on 7 scanner types (4 vendors) and clinically indicated echocardiography within 31 days. A commercially available AI tool (AI-Rad Companion, Siemens Healthineers) automatically quantified TCVAI, indexed to body surface area (TCVAI/BSA). Echocardiography reports were reviewed for chamber dilation and left ventricular hypertrophy (LVH), collectively defined as cardiomegaly. Associations between TCVAI/BSA and echocardiographic findings were assessed using correlation, ordinal regression, and receiver operating characteristic (ROC). Interscan repeatability was evaluated in 248 patients with 544 repeat CT examinations. Prespecified sex-specific thresholds were tested in a temporally independent validation cohort of 50 patients. Results Median TCVAI was higher in patients with cardiomegaly than those without (1061.9 vs 798.4 mL; P < .001). TCVAI/BSA was associated with chamber dilation and LVH severity on univariate analysis and remained associated in multivariable ordinal models, except for right ventricular dilation. Discriminatory performance was fair to good, with area under the curve (AUC) 0.81 (95% CI, 0.75-0.87) in men and 0.77 (95% CI, 0.69-0.85) in women. Interscan repeatability was excellent (intraclass correlation coefficient [ICC]: 0.93). In independent validation, performance ranged from sensitivity 89.3%/specificity 27.3% at a high-sensitivity threshold to sensitivity 28.6%/specificity 100% at a high-specificity threshold. Conclusion AI-derived cardiac volume from routine chest CT shows fair to good performance for identifying echocardiography-defined cardiomegaly with high measurement repeatability, supporting a potential role for automated cardiac volumetry as an objective, opportunistic biomarker.
Summary of the AAPM task group 248 report: Interoperability assessment for the commissioning of medical imaging acquisition systems
Walz‐Flannigan, Alisa , Weiser, John C., Goode, Allen R. , Junck, Kevin L., Tarbox, Lawrence , Dave, Jaydev K. , Clunie, David , Langer, Steve G., McColl, Roderick W.

Medical Physics | May 6, 2019 | Volume: 46 | Issue: 7 | Pages: No page available

10.1002/mp.13571 Get It

PurposeWe summarize the AAPM TG248 Task Group report on interoperability assessment for the commissioning of medical imaging acquisition systems in order to bring needed attention to the value and role of quality assurance testing throughout the imaging chain.MethodsTo guide the clinical physicist involved in commissioning of imaging systems, we describe a framework and tools for incorporating interoperability assessment into imaging equipment commissioning.ResultsWhile equipment commissioning may coincide with equipment acceptance testing, its scope may extend beyond validation of product or purchase specifications. Equipment commissioning is meant to provide assurance that a system is ready for clinical use, and system interoperability plays an essential role in the clinical use of an imaging system.ConclusionThe functionality of a diagnostic imaging system extends beyond the acquisition console and depends on interoperability with a host of other systems such as the Radiology Information System, a Picture Archive and Communication System, post‐processing software, treatment planning software, and clinical viewers.