Back to Authors

Kay, Fernando Uliana

https://orcid.org/0000-0002-9467-2013

Mayo Clinic

The University of Texas MD Anderson Cancer Center

Citations 4

Artificial intelligence-enabled cardiac volumetry for opportunistic screening of cardiomegaly on chest CT: clinical validation with echocardiography
Fan, Christopher , Scanio, Angelo , Yokoo, Patrícia , Wiessman, Maya , Lewis, Matthew A. , Xi, Yin, Duan, Xinhui, McColl, Roderick M, Kay, Fernando Uliana , Fan, Christopher M , Abbara, Suhny , Kay, Fernando , Long, Michael, Duan, Xinhui , McColl, Roderick W. , Peshock, Ronald M.

Radiology Advances | March 3, 2026 | Volume: 3 | Issue: 2 | Pages: No page available

10.1093/radadv/umag013 Get It

Abstract Background Cardiomegaly is a clinically significant incidental finding on chest computed tomography (CT) associated with heart failure, arrhythmias, and sudden cardiac death. Qualitative radiologist assessment is variable, and automated AI tools may enable objective opportunistic cardiac volumetry. Purpose To evaluate whether AI-enabled total cardiac volume (TCVAI) derived from non-ECG-gated, non-contrast chest CT can identify cardiomegaly as defined by echocardiography. Materials and Methods This retrospective study included 307 consecutive patients (median age, 67 years; 56% male) who underwent non-contrast chest CT at a single center on 7 scanner types (4 vendors) and clinically indicated echocardiography within 31 days. A commercially available AI tool (AI-Rad Companion, Siemens Healthineers) automatically quantified TCVAI, indexed to body surface area (TCVAI/BSA). Echocardiography reports were reviewed for chamber dilation and left ventricular hypertrophy (LVH), collectively defined as cardiomegaly. Associations between TCVAI/BSA and echocardiographic findings were assessed using correlation, ordinal regression, and receiver operating characteristic (ROC). Interscan repeatability was evaluated in 248 patients with 544 repeat CT examinations. Prespecified sex-specific thresholds were tested in a temporally independent validation cohort of 50 patients. Results Median TCVAI was higher in patients with cardiomegaly than those without (1061.9 vs 798.4 mL; P < .001). TCVAI/BSA was associated with chamber dilation and LVH severity on univariate analysis and remained associated in multivariable ordinal models, except for right ventricular dilation. Discriminatory performance was fair to good, with area under the curve (AUC) 0.81 (95% CI, 0.75-0.87) in men and 0.77 (95% CI, 0.69-0.85) in women. Interscan repeatability was excellent (intraclass correlation coefficient [ICC]: 0.93). In independent validation, performance ranged from sensitivity 89.3%/specificity 27.3% at a high-sensitivity threshold to sensitivity 28.6%/specificity 100% at a high-specificity threshold. Conclusion AI-derived cardiac volume from routine chest CT shows fair to good performance for identifying echocardiography-defined cardiomegaly with high measurement repeatability, supporting a potential role for automated cardiac volumetry as an objective, opportunistic biomarker.
Detection of Low Blood Hemoglobin Levels on Pulmonary CT Angiography: A Feasibility Study Combining Dual-Energy CT and Machine Learning
Kay, Fernando Uliana , Lumby, Cynthia, Kay, Fernando , Tanabe, Yuki , Abbara, Suhny , Rajiah, Prabhakar

Tomography | August 18, 2023 | Volume: 9 | Issue: 4 | Pages: 1538-1550

10.3390/tomography9040123 Get It

Objectives: To evaluate if dual-energy CT (DECT) pulmonary angiography (CTPA) can detect anemia with the aid of machine learning. Methods: Inclusion of 100 patients (mean age ± SD, 51.3 ± 14.8 years; male-to-female ratio, 42/58) who underwent DECT CTPA and hemoglobin (Hb) analysis within 24 h, including 50 cases with Hb below and 50 controls with Hb ≥ 12 g/dL. Blood pool attenuation was assessed on virtual noncontrast (VNC) images at eight locations. A classification model using extreme gradient-boosted trees was developed on a training set (n = 76) for differentiating cases from controls. The best model was evaluated in a separate test set (n = 24). Results: Blood pool attenuation was significantly lower in cases than controls (p-values < 0.01), except in the right atrium (p = 0.06). The machine learning model had sensitivity, specificity, and accuracy of 83%, 92%, and 88%, respectively. Measurements at the descending aorta had the highest relative importance among all features; a threshold of 43 HU yielded sensitivity, specificity, and accuracy of 68%, 76%, and 72%, respectively. Conclusion: VNC imaging and machine learning shows good diagnostic performance for detecting anemia on DECT CTPA.
RadioGraphics Update: Pictorial Guide to CAD-RADS 2.0
Canan, Arzu , Kay, Fernando Uliana , Barbosa, Maurício Fregonesi , Abbara, Suhny , Rajiah, Prabhakar , Kay, Fernando , Rajiah, Prabhakar

RadioGraphics | March 30, 2023 | Volume: 43 | Issue: 4 | Pages: No page available

10.1148/rg.220202 Get It

Update on Multienergy CT: Physics, Principles, and Applications
Rajiah, Prabhakar , Parakh, Anushri , Kay, Fernando Uliana , Kambadakone, Avinash , Leng, Shuai , Kay, Fernando , Baruah, Dhiraj, Kambadakone, Avinash R , Leng, Shuai , Rajiah, Prabhakar , Baruah, Dhiraj

RadioGraphics | August 21, 2020 | Volume: 40 | Issue: 5 | Pages: 1284-1308

10.1148/rg.2020200038 Get It