Back to Authors

Gotkin, Robert H.

0000-0003-4757-5912

Mayo Clinic

Erasmus MC

Citations 17

Differences in Temporal Volume between Males and Females and the Influence of Age and BMI: A Cross-Sectional CT-Imaging Study
Nikolis, Andreas , Frank, Konstantin , Guryanov, R. A. , Gombolevskiy, Victor А. , Makhmud, Kamal, Green, Jeremy Blair, Морозов, С. П. , Chernina, Valeria Y. , Gotkin, Robert H. , Cotofana, Sebastian

Facial Plastic Surgery | March 9, 2021 | Volume: 37 | Issue: 05 | Pages: 632-638

10.1055/s-0041-1725201 Get It

Abstract Background The temple has been identified as one of the most compelling facial regions in which to seek aesthetic improvement—both locally and in the entire face—when injecting soft tissue fillers. Objective The objective of this study is to identify influences of age, gender, and body mass index (BMI) on temporal parameters to better understand clinical observations and to identify optimal treatment strategies for treating temporal hollowing. Methods The sample consisted of 28 male and 30 female individuals with a median age of 53 (34) years and a median BMI of 27.00 (6.94) kg/m2. The surface area of temporal skin, the surface area of temporal bones, and the temporal soft tissue volume were measured utilizing postprocessed computed tomography (CT) images via the Hausdorff minimal distance algorithm. Differences between the investigated participants related to age, BMI, and gender were calculated. Results Median skin surface area was greater in males compared with females 5,100.5 (708) mm2 versus 4,208.5 (893) mm2 (p < 0.001) as was the median bone surface area 5,329 (690) mm2 versus 4,477 (888) mm2 (p < 0.001). Males had on average 11.04 mL greater temporal soft tissue volume compared with age and BMI-matched females with p < 0.001. Comparing the volume between premenopausal versus postmenopausal females, the median temporal soft tissue volume was 46.63 mL (11.94) versus 40.32 mL (5.69) (p = 0.014). Conclusion The results of this cross-sectional CT imaging study confirmed previous clinical and anatomical observations and added numerical evidence to those observations for a better clinical integration of the data.
Signal-To-Noise Ratio Calculations to Validate Sensor Positioning for Facial Muscle Assessment Using Noninvasive Facial Electromyography
Frank, Konstantin , Alfertshofer, Michael , Patel, Ashit , Smith, Michael P. , Gavril, Diana L., Alfertshofer, Michael , Moellhoff, Nicholas , Kaiser, Antonia , Gotkin, Robert H. , Mardini, Samir , Cotofana, Sebastian

Facial Plastic Surgery | March 8, 2021 | Volume: 37 | Issue: 05 | Pages: 614-624

10.1055/s-0041-1725168 Get It

AbstractThe evaluation of neuromodulator treatment outcomes can be performed by noninvasive surface-derived facial electromyography (fEMG) which can detect cumulative muscle fiber activity deep to the skin. The objective of the present study is to identify the most reliable facial locations where the motor unit action potentials (MUAPs) of various facial muscles can be quantified during fEMG measurements. The study population consisted of five males and seven females (31.0 [12.9] years, body mass index of 22.15 [1.6] kg/m2). Facial muscle activity was assessed in several facial regions in each patient for their respective muscle activity utilizing noninvasive surface-derived fEMG. Variables of interest were the average root mean square of three performed muscle contractions (= signal) (µV), mean root mean square between those contraction with the face in a relaxed facial expression (= baseline noise) (µV), and the signal to noise ratio (SNR). A total of 1,709 processed fEMG signals revealed one specific reliable location in each investigated region based on each muscle's anatomy, on the highest value of the SNR, on the lowest value for the baseline noise, and on the practicability to position the sensor while performing a facial expression. The results of this exploratory study may help guiding future researchers and practitioners in designing study protocols and measuring individual facial MUAP when utilizing fEMG. The locations presented herein were selected based on the measured parameters (SNR, signal, baseline noise) and on the practicability and reproducibility of sensor placement.
The Course of the Angular Artery in the Midface: Implications for Surgical and Minimally Invasive Procedures
Gombolevskiy, Victor А. , Gelezhe, Pavel , Морозов, С. П. , Vorontsov, Alexander , Kulberg, Nikolay, Frank, Konstantin , Lachman, Nirusha , Melnikov, D. V. , Gotkin, Robert H. , Cotofana, Sebastian

Aesthetic Surgery Journal | June 27, 2020 | Volume: 41 | Issue: 7 | Pages: 805-813

10.1093/asj/sjaa176 Get It

Abstract Background Previous anatomic studies have provided valuable information on the 2-dimensional course of the angular segment of the facial artery in the midface and its arterial connections. The third dimension (ie, the depth of the artery) is less well characterized. Objectives The objective of the present study was to describe the 3-dimensional pathway of the angular segment of the facial artery and its relationship to the muscles of facial expression. Methods The bilateral location and the depth of the midfacial segment of the facial artery was measured utilizing multi-planar computed tomographic image analyses obtained from contrast agent-enhanced cranial computed tomographic scans of 156 Caucasians aged a of 45.19 ± 18.7 years and with a mean body mass index of 25.05 ± 4.9 kg/m2. Results At the nasal ala, the mean depth of the main arterial trunk was 13.7 ± 3.7 mm (range, 2.7-25.0 mm), whereas at the medial canthus it was 1.02 ± 0.62 mm (range, 1.0-3.0 mm). This was reflected by the arteries’ relationship to the midfacial muscles: at the nasal ala superficial to levator anguli oris in 62.0% but deep to the levator labii superioris alaeque nasi in 53.6%; at the medial canthus superficial to the levator labii superioris alaeque nasi in 83.1% and superficial to the orbicularis oculi in 82.7%. Conclusions The results presented herein confirm the high variability in the course of the angular segment of the facial artery. Various arterial pathways have been identified providing evidence that, in the midface, there is no guaranteed safe location for minimally invasive procedures.
The Influence of the Insertion Angle on Middle and Lower Face Tissue-Mechanics When Treating the Nasolabial Folds with Facial Suspension Threads—An Experimental Split-Face Cadaveric Study
Frank, Konstantin , Freytag, David L., Lachman, Nirusha , Hsu, Gloria, Gavril, Diana L., Silva, Maria V., Bialowas, Christie , Braun, Martin, Gotkin, Robert H. , Hsu, Gloria P., Silva, Maria V., Cotofana, Sebastian

Facial Plastic Surgery | June 8, 2020 | Volume: 36 | Issue: 03 | Pages: 268-275

10.1055/s-0040-1712469 Get It

AbstractA novel treatment approach to address the nasolabial fold is the insertion facial suspension threads. However, there is a paucity of data available to guide insertion techniques and material selection. Three female and two male cephalic specimens of Caucasian ethnicity (73.6 ± 6.5 years; 21.41 ± 2.2 kg/m2) were included into this experimental split-face study. One facial side was treated with polycaprolactone (PCL) thread: 180 mm, bidirectional, 18G 100 mm cannula, 20 degrees trajectory, preauricular approach whereas the contralateral side was treated with polydioxanone (PDO) thread: 100 mm, bidirectional, 19G, 60 mm cannula, 50 degrees trajectory, infraorbital approach. Three-dimensional imaging outcome measures included vertical and horizontal skin displacement and volume changes at the nasolabial sulcus, at the labiomandibular sulcus, and along the jawline. Comparing PCL 180 mm 20 degrees to PDO 100 mm 50 degrees: vertical lifting effect 1.42 ± 2.63 mm versus 1.24 ± 1.88 mm (p = 0.906); horizontal lifting effect 3.42 ± 1.44 mm versus –2.02 ± 1.84 mm (p = 0.001); nasolabial volume change –0.80 ± 0.65 mL versus –0.52 ± 0.17 mL (p = 0.367); labiomandibular volume change –0.45 ± 0.42 mL versus –0.16 ± 0.16 mL (p = 0.191); jawline volume change 0.02 ± 0.43 mL versus –0.01 ± 0.21 mL (p = 0.892). The study provides objective evidence for the short-term effectiveness of facial suspension threads in treating the nasolabial folds. The results point toward a better aesthetic outcome when utilizing long facial suspension threads that can effect full-face changes as compared with short facial suspension threads.
Three-Dimensional Description of the Angular Artery in the Nasolabial Fold
Gelezhe, Pavel , Gombolevskiy, Victor А. , Морозов, С. П. , Melnikov, D. V. , Корб, Т. А. , Aleshina, Olga , Frank, Konstantin , Aleshina, Olga Olegovna, Gotkin, Robert H. , Green, Jeremy B. , Cotofana, Sebastian

Aesthetic Surgery Journal | June 6, 2020 | Volume: 41 | Issue: 6 | Pages: 697-704

10.1093/asj/sjaa152 Get It

Abstract Background Due to its arterial vasculature, the nasolabial sulcus is one of the most challenging facial regions to treat when trying to ameliorate the signs of facial aging. Objectives The aim of the present study was to provide data on the 3-dimensional course of the angular artery within the nasolabial sulcus in relation to age, gender, and body mass index to increase safety during minimally invasive treatments. Methods Thee hundred nasolabial sulci from 75 males and 75 females of Russian Caucasian ethnic background (mean [standard deviation] age, 45.7 [18.7] years; mean body mass index, 25.14 [4.9] kg/m2) were analyzed. Bilateral multiplanar measurements were based on contrast-enhanced computed tomography cranial scans. Results Up to 3 arteries could be identified within the nasolabial sulcus: ~90% contained 1 arterial trunk, ~9% had 2 trunks, and ~1% had 3 trunks; females had more arteries than men. The artery is located at mean depths of 21.6 mm at the oral commissure and 8.9 mm at the nasal ala. The angular artery was lateral to the nasolabial sulcus in 100% of cases; the smallest distance between the artery and the nasolabial sulcus was at the oral commissure (11.91 [7.9] mm) and the greatest was at the nasal ala (13.73 [3.9] mm). Conclusions In contrast to current concepts, the angular artery is not located strictly subdermal to the nasolabial sulcus but at a variable depth, and in 100% of the investigated cases lateral to the nasolabial sulcus. With increasing age, the depth and lateral distance between arteries and sulci reduces significantly, underscoring the need for special caution when injecting this site.
Anatomy Behind the Facial Overfilled Syndrome: The Transverse Facial Septum
Frank, Konstantin , Lachman, Nirusha , Schenck, Thilo L., Cotofana, Sebastian , Gotkin, Robert H.

Dermatologic Surgery | November 4, 2019 | Volume: 46 | Issue: 8 | Pages: e16-e22

10.1097/dss.0000000000002236 Get It

BACKGROUND The midface is an area of high demand for minimally invasive cosmetic procedures, that is, soft-tissue filler injections. OBJECTIVE To investigate the functional anatomy behind the facial overfilled syndrome observed after soft-tissue filler injections. MATERIALS AND METHODS The clinical part of the study enrolled 25 volunteers (12 men and 13 women, Caucasians); the anatomical part included 72 fresh frozen cephalic specimens obtained from 32 male and 40 female body donors. 3D surface scanning procedures were applied to calculate the maximal anterior projection of the midface. RESULTS Upon smiling, the point of maximal anterior projection shifted cranially in men by 12.43 ± 8.8 mm (difference between resting and smiling; p < .001) and by 8.75 ± 4.1 mm in women (p < .001). Cadaveric dissections identified a septum originated from the underside of the zygomaticus major muscle forming a transversely running boundary between the buccal space and the deep midfacial fat compartments. CONCLUSION Facial overfilled syndrome can potentially be explained by the presence of the transverse facial septum. Dynamic filling—injecting small amounts of filler and asking the patient to smile repeatedly during the procedure—seems to be a viable way to avoid this adverse event during soft-tissue filler injection.
Influence of Age, Sex, and Body Mass Index on the Thickness of the Gluteal Subcutaneous Fat: Implications for Safe Buttock Augmentation Procedures
Frank, Konstantin , Kaye, Kai , Lorenc, Paul, Schenck, Thilo L., Lachman, Nirusha , Durán-Vega, Héctor César , Cotofana, Sebastian, Gotkin, Robert H., Kaye, Kai O, Lorenc, Paul Z, Green, Jeremy B, Duran-Vega, Héctor, Casabona, Gabriela , Gotkin, Robert H. , Green, Jeremy B. , Cotofana, Sebastian

Plastic & Reconstructive Surgery | April 18, 2019 | Volume: 144 | Issue: 1 | Pages: 83-92

10.1097/prs.0000000000005707 Get It

Background: The deep intramuscular approach during buttock augmentation with fat grafting has been associated with a significantly increased risk for pulmonary fat embolism. This study was designed to provide guidance for injection into the subcutaneous fat. Methods: The authors investigated 150 Caucasian individuals with an equal distribution of men and women (n = 75 each) and a balanced distribution of age (n = 30 per decade: 20 to 29, 30 to 39, 40 to 49, 50 to 59, and 60 to 69 years) and body mass index (n = 50 per group: ≤24.9 kg/m2, between 25.0 and 29.9kg/m2, and ≥30 kg/m2). Ultrasound-based measurements were conducted of the thickness of the total, superficial, and deep gluteal fatty layers. Results: An increase in body mass index of 1.0 kg/m2 corresponded to an increase of 3 mm of the total gluteal subcutaneous fat of men and a 4-mm increase of the total gluteal subcutaneous fat in women. With increasing age, the thickness of the deep fatty layer increased, whereas with increasing body mass index the thickness of the superficial layer primarily increased. Formulas were generated to estimate the total thickness of the gluteal subcutaneous fatty layer for men [total thickness (in millimeters) = −33.56 + (age × 0.078) + (body mass index × 3.042)] and women [total thickness (in millimeters) = −56.997 + (age × 0.1) + (body mass index × 3.86)]. Conclusions: Knowing the total thickness of the gluteal subcutaneous fat (i.e., the safe space) allows surgeons to estimate their operating range for cannula motion even if no ultrasound machine is available during buttock augmentation with fat grafting. This can increase safety, potentially reducing the number of adverse events.