Back to Authors

Ebner, Adrián

Mayo Clinic

Amplifi Vascular, Kansas City, Kansas, United States

Citations 2

Abstract 4145497: Pump-Assisted Vein Dilation for Arteriovenous Fistula Creation – Translation of the Amplifi Vein Dilation System from Bench to Bedside
Shenoy, Surendra, Ebner, Adrián, Macedo, Mark , Peralta, Emma Esperanza Bravo, Fritterer, Mimi, Mani, K.C. Kapil, Brown, Michael C. , Tansley, Geoffrey Douglas, Franano, Nicholas, Treffalls, Rebecca N. , Peralta, Erdie De, Richardson, Scott, Mani, Krishnil, Tansley, Geoffrey D., Muller, Paul, Morrison, Jonathan J.

Circulation | November 14, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4145497 Get It

Background: Autologous arteriovenous fistulas (AVF) are the preferred choice for hemodialysis access due to their longevity, lower complication rates, and mortality benefit. Their use is limited by vein size and necessary maturation period, excluding up to a third of patients. A novel solution to this problem is pump-assisted vein dilation (PAVD), where the vein is “pre-matured” using a miniatured centrifugal pump that draws blood from a central vein, delivering it into the recipient vein (e.g., cephalic) under pressure. The aim of this study is to report the initial safety studies in sheep and a first-in-human (FIH) pilot study as a prelude to a phase 2 clinical study. Methods: Preclinical Study: Three anesthetized male sheep (50-70 kg) underwent cephalic PAVD using the Amplifi Vein Dilation System for 7 days (mean). These subjects and two control animals (no-PAVD) underwent brachiocephalic AVF creation and observation for 6 weeks, with weekly surveillance fistulagrams and duplex ultrasound (U/S). AVFs were then explanted for histological analysis. Clinical Study: Ten patients were recruited for a phase 1 study. They underwent cephalic PAVD for 7 days (mean), followed by brachiocephalic AVF creation and surveillance at 2 and 6 wks. Data on vein diameter and flow rates of the AVF were collected, as well as safety data on complications such as bleeding, infection, and embolism. Results: Preclinical Study: PAVD increased mean±SD vein diameter (mm) from 4.5±1.0 to 8.4±1.0 (p=0.005); leading to greater cephalic vein diameter at the time of AVF creation in the PAVD group vs no-PAVD (8.2±1.3 vs. 3.3±0.7; p<0.05). After 6 wks of maturation, mean vein diameter was still greater in the PAVD group compared to no-PAVD (12.8±2.8 vs. 8.4±0.7; p<0.05). Mean flow increased at 41 mL/min/day versus control animals at 5.2 mL/min/day. Clinical Study: All subjects saw an increase in vein diameter with PAVD at baseline vs. at 6 wks (2.3±0.5 vs. 5.2±0.7; p<0.05), as well as mean flows (mL/min) (285±30 vs. 724±149). There were no Amplifi-related or procedure-related serious adverse events. Conclusion: The translation of PAVD for AVF creation from bench-to-bedside provides safety and efficacy data on a novel solution that can increase the availability of autologous AVFs in patients excluded due to size criteria. The Amplifi vein dilation system can effectively and rapidly dilate peripheral veins without stimulating neointimal hyperplasia. PAVD should be explored in a phase 2 clinical study.
A lumen sizing workhorse guidewire for peripheral vasculature: Two functions in one device
Svendsen, Mark, Choy, Jenny S. , Ebner, Adrián, Bigelow, Brian, Sinha, Anjan , Moussa, Issam , Akingba, A. George, Combs, Bill, Kassab, Ghassan S.

Catheterization and Cardiovascular Interventions | April 16, 2013 | Volume: 83 | Issue: 1 | Pages: No page available

10.1002/ccd.24950 Get It

ObjectivesIdeally, guidewires used during peripheral vasculature (PV) interventions could serve both as a therapy delivery platform and a diagnostic tool for real‐time vessel sizing (2‐in‐1 function).BackgroundVascular imaging modalities, like intravascular ultrasound (IVUS), used during lower PV interventions, can improve outcomes versus angiographic assessment alone, but are rarely used due to added time, cost, and required clinical training/interpretation.MethodsA 0.035″ bodied 0.035″ conductance guidewire (CGW) is described here as a vascular navigation and diagnostic real‐time PV sizing tool. When attached to a console, the CGW creates a safe, electric field to determine vascular size through simultaneous voltage measurements.ResultsThe CGW showed functionality as a workhorse guidewire on the bench (torqueability and trackability equivalent to a Wholey guidewire) and in vivo (over‐the‐wire stent deployment in domestic swine and first‐in‐man study with no major adverse events). Validation of CGW sizing versus the true diameter and IVUS was completed in 4–10 mm diameter phantoms on the bench and in swine and showed virtually no bias with excellent repeatability and accuracy (i.e., CGW repeatability: swine phantom bias = 0.03 ± 0.09 mm (1.3% error). CGW vs. true diameter: in vivo bias = 0.14 ± 0.15 mm (2.7% error). IVUS vs. true diameter: swine phantom bias = 0.01 ± 0.36 mm (4.7% error). CCW vs. IVUS: swine phantom bias = 0.13 ± 0.26mm (3.8% error)).ConclusionsReal‐time, accurate, and safe PV dimension assessment and therapy‐delivery (2‐in‐1 function) is possible using a novel workhorse 0.035″ bodied CGW. © 2013 Wiley Periodicals, Inc.