Background Tricuspid regurgitation (TR) is a common valvular disorder that can affect patients’ quality of life and survival. The impact of TR etiology on overall survival and the associated risk factors in each subgroup are not well studied. Methods Multisite, retrospective study evaluating survival based on TR etiology using Kaplan–Meier and Cox regression models. Stepwise approach was used to define TR etiology (≥moderate): primary (PTR; presence of a primary valvular pathology), lead associated (LTR; lead interfering with closure), and secondary TR (STR) in the setting of left‐sided valvular disease, left ventricular disease, other causes of pulmonary hypertension, right ventricular disease, and atrial secondary TR. Results A total of 12 899 patients were included (3% PTR, 90% STR, 7% LTR). The mean age was 68±14, 73±13, and 71±13 years, respectively (44%–55% female patients). Adjusting for age, sex, and TR severity, patients with PTR had better overall survival (PTR: reference; STR hazard ratio [HR], 1.4 [1.2–1.6], LTR HR, 1.5 [1.1–1.7]). On multivariable Cox regression, the Tricuspid Regurgitation Impact on Outcomes score was associated with mortality across all groups ( P <0.05 for all). In addition, other risk factors associated with worse outcomes included pulmonary hypertension and ≥moderate right ventricular enlargement in PTR; left‐sided valvular disease, pulmonary hypertension, and ≥moderate right ventricular dysfunction in STR; and left ventricular disease and ≥moderate right ventricular dysfunction in LTR. Conclusions Patients with PTR have better survival than STR and LTR. Tricuspid Regurgitation Impact on Outcomes score was associated with mortality across etiologies, whereas other risk factors are etiology specific. Improved risk profiling may enhance patient selection, treatment decisions, and outcomes.
Atrial fibrillation is associated with large beat-to-beat variability in mitral and tricuspid annulus dimensions
Abstract Aims Beat-to-beat variability in cycle length is well-known in atrial fibrillation (Afib); whether this also translates to variability in annulus size remains unknown. Defining annulus maximal size in Afib is critical for accurate selection of percutaneous devices given the frequent association with mitral and tricuspid valve diseases. Methods and results Images were obtained from 170 patients undergoing 3D echocardiography [100 (50 sinus rhythm (SR) and 50 Afib) for mitral annulus (MA) and 70 (35 SR and 35 Afib) for tricuspid annulus (TA)]. Images were analysed for differences in annular dynamics with a commercially available software. Number of cardiac cycles analysed was 567 in mitral valve and 346 in tricuspid valve. Median absolute difference in maximal MA area over four to six cycles was 1.8 cm2 (range 0.5–5.2 cm2) in Afib vs. 0.8 cm2 (range 0.1–2.9 cm2) in SR, P < 0.001. Maximal MA area was observed within 30–70% of the R-R interval in 81% of cardiac cycles in SR and in 73% of cycles in Afib. Median absolute difference in maximal TA area over four to six cycles was 1.4 cm2 (range 0.5–3.6 cm2) in Afib vs. 0.7 cm2 (range 0.3–1.7 cm2) in SR, P < 0.001. Maximal TA area was observed within 60–100% of the R-R interval in 81% of cardiac cycles in SR, but only in 49% of cycles in Afib. Conclusion MA and TA reach maximal size within a broad time interval centred around end-systole and end-diastole, respectively, with significant beat-to-beat variability. Afib leads to a larger beat-to-beat variability in both timing of occurrence and values of annulus size than in SR.
Beat-to-beat variability in the tricuspid annulus dimensions and dynamics is markedly increased in atrial fibrillation
Abstract Background Atrial fibrillation (Afib) leads to beat-to-beat variability in cycle length; however, whether there is associated beat-to-beat variability in the tricuspid annulus (TA) dimensions or variability in the time in cardiac cycle when TA reaches maximal size is unknown. Purpose We aim to assess the beat-to-beat variability in the TA dimensions in Afib compared with sinus rhythm (SR). Methods Images were obtained from 58 patients (29 in Afib, 29 in SR) undergoing either 3D TTE or TEE examination. We measured TA in 3–6 cardiac cycles per patient using commercially available software (TomTec 4MV). Results Median absolute difference in maximal TA area over 3–6 cardiac cycles was 1.60 cm2 (range 0.35 cm2 to 4.08 cm2) in Afib vs. 1.17 cm2 (range 0.32 cm2 to 2.19 cm2) in SR, p=0.0063. Median absolute difference in the maximal circumference was 0.79 cm (range 0.09 cm to 2.2 cm) in Afib vs 0.54 cm (range 0.12 cm to 1.43 cm) in SR, p=0.0175. A total of 118 cardiac cycles were analyzed in patients in SR and 147 in Afib. Timing of maximal TA area was most commonly recorded at end-diastole (80–100% of the R-R interval) in 62% of cycles in SR; however, it was distributed over a broad range in Afib, p<0.0001, [Figure]. Conclusion Afib leads to significant beat-to-beat variability in the maximal TA area, minimal TA area, maximal TA circumference, and in the time of maximal TA area. These findings suggest that accurate assessment of TA dimensions should be based on continuous tracking of the TA over several cardiac cycles, especially in patients with Afib. These observations have significant implications for device sizing in percutaneous tricuspid valve interventions. Timing of Maximal TA Area Funding Acknowledgement Type of funding source: None