Back to Authors

Lymp, James

Mayo Clinic

Section of Biostatistics,

Citations 5

Correlation of Serum Immunoglobulin Free Light Chain Quantification with Urinary Bence Jones Protein in Light Chain Myeloma
Abraham, Roshini S. , Clark, Raynell, Bryant, Sandra C. , Lymp, James, Larson, Timothy , Kyle, Robert A. , Katzmann, Jerry A.

Clinical Chemistry | July 17, 2020 | Volume: 48 | Issue: 4 | Pages: 655-657

10.1093/clinchem/48.4.655 Get It

Serum Reference Intervals and Diagnostic Ranges for Free κ and Free λ Immunoglobulin Light Chains: Relative Sensitivity for Detection of Monoclonal Light Chains
Katzmann, Jerry A., Clark, Raynell, Abraham, Roshini S. , Bryant, Sandra C. , Lymp, James, Kyle, Robert A. , Bradwell, A.R.

Clinical Chemistry | January 24, 2020 | Volume: 48 | Issue: 9 | Pages: 1437-1444

10.1093/clinchem/48.9.1437 Get It

AbstractBackground: The detection of monoclonal free light chains (FLCs) is an important diagnostic aid for a variety of monoclonal gammopathies and is especially important in light-chain diseases, such as light-chain myeloma, primary systemic amyloidosis, and light-chain-deposition disease. These diseases are more prevalent in the elderly, and assays to detect and quantify abnormal amounts of FLCs require reference intervals that include elderly donors.Methods: We used an automated immunoassay for FLCs and sera from a population 21–90 years of age. We used the calculated reference and diagnostic intervals to compare FLC results with those obtained by immunofixation (IFE) to detect low concentrations of monoclonal κ and λ FLCs in the sera of patients with monoclonal gammopathies.Results: Serum κ and λ FLCs increased with population age, with an apparent change for those >80 years. This trend was lost when the FLC concentration was normalized to cystatin C concentration. The ratio of κ FLC to λ FLC (FLC K/L) did not exhibit an age-dependent trend. The diagnostic interval for FLC K/L was 0.26–1.65. The 95% reference interval for κ FLC was 3.3–19.4 mg/L, and that for λ FLC was 5.7–26.3 mg/L. Detection and quantification of monoclonal FLCs by nephelometry were more sensitive than IFE in serum samples from patients with primary systemic amyloidosis and light-chain-deposition disease.Conclusions: Reference and diagnostic intervals for serum FLCs have been developed for use with a new, automated immunoassay that makes the detection and quantification of monoclonal FLCs easier and more sensitive than with current methods. The serum FLC assay complements IFE and allows quantification of FLCs in light-chain-disease patients who have no detectable serum or urine M-spike.
Characterizing the Emotions That Trigger Cataplexy
Krahn, Lois E., Lymp, James, Moore, Wendy , Slocumb, Nancy L., Silber, Michael H.

The Journal of Neuropsychiatry and Clinical Neurosciences | December 17, 2014 | Volume: 17 | Issue: 1 | Pages: 45-50

10.1176/jnp.17.1.45 Get It

Hypercapnic Acidosis Impairs Plasma Membrane Wound Resealing in Ventilator-injured Lungs
Doerr, Clinton H., Gajić, Ognjen, Berríos, Jorge, Caples, Sean M., Abdel, Matthew, Lymp, James, Hubmayr, Rolf D.

American Journal of Respiratory and Critical Care Medicine | February 2, 2005 | Volume: 171 | Issue: 12 | Pages: 1371-1377

10.1164/rccm.200309-1223oc Get It

Abstract The objective of this study was to assess the effects of hypercapnic acidosis on lung cell injury and repair by confocal microscopy in a model of ventilator-induced lung injury. Three groups of normocapnic, hypocapnic, and hypercapnic rat lungs were perfused ex vivo, either during or after injurious ventilation, with a solution containing the membrane-impermeant label propidium iodide. In lungs labeled during injurious ventilation, propidium iodide fluorescence identifies all cells with plasma membrane wounds, both permanent and transient, whereas in lungs labeled after injurious ventilation propidium iodide fluorescence identifies only cells with permanent plasma membrane wounds. Hypercapnia minimized the adverse effects of high-volume ventilation on vascular barrier function, whereas hypocapnia had the opposite effect. Despite CO2-dependent differences in lung mechanics and edema the number of injured subpleural cells per alveolus was similar in the three groups (0.48 ± 0.34 versus 0.51 ± 0.19 versus 0.43 ± 0.20 for hypocapnia, normocapnia, and hypercapnia, respectively). However, compared with normocapnia the probability of wound repair was significantly reduced in hypercapnic lungs (63 versus 38%; p < 0.02). This finding was subsequently confirmed in alveolar epithelial cell scratch models. The potential relevance of these observations for lung inflammation and remodeling after mechanical injury is discussed.
Improved Specificity of Newborn Screening for Congenital Adrenal Hyperplasia by Second-Tier Steroid Profiling Using Tandem Mass Spectrometry
Lacey, Jean M., Minutti, Carla , Magera, Mark J , Tauscher, Angela L., Casetta, Bruno , McCann, Mark, Lymp, James, Hahn, Si Houn , Rinaldo, Piero, Matern, Dietrich

Clinical Chemistry | February 23, 2004 | Volume: 50 | Issue: 3 | Pages: 621-625

10.1373/clinchem.2003.027193 Get It

Abstract Background: Newborn screening for congenital adrenal hyperplasia (CAH) involves measurement of 17α-hydroxyprogesterone (17-OHP), usually by immunoassay. Because this testing has been characterized by high false-positive rates, we developed a steroid profiling method that uses liquid chromatography–tandem mass spectrometry (LC-MS/MS) to measure 17-OHP, androstenedione, and cortisol simultaneously in blood spots. Methods: Whole blood was eluted from a 4.8-mm (3/16-inch) dried-blood spot by an aqueous solution containing the deuterium-labeled internal standard d8-17-OHP. 17-OHP, androstenedione, and cortisol were extracted into diethyl ether, which was subsequently evaporated and the residue dissolved in LC mobile phase. This extract was injected into a LC-MS/MS equipped with pneumatically assisted electrospray. The steroids were quantified in the selected-reaction monitoring mode by use of peak areas in reference to the stable-isotope-labeled internal standard. We analyzed 857 newborn blood spots, including 14 blood spots of confirmed CAH cases and 101 of false-positive cases by conventional screening. Results: Intra- and interassay CVs for 17-OHP were 7.2–20% and 3.9–18%, respectively, at concentrations of 2, 30, and 50 μg/L. At a cutoff for 17-OHP of 12.5 μg/L and a cutoff of 3.75 for the sum of peak areas for 17-OHP and androstenedione divided by the peak area for cortisol, 86 of the 101 false-positive samples were within reference values by LC-MS/MS, whereas the 742 normal and 14 true-positive results obtained by conventional screening were correctly classified. Conclusion: Steroid profiling in blood spots can identify false-positive results obtained by conventional newborn screening for CAH.