Back to Authors

Hyer, Daniel

0000-0002-7638-9599

Mayo Clinic

University of Iowa, Iowa City, IA.

Citations 4

Improved Survival and Prognostication in Melanoma Patients With Brain Metastases: An Update of the Melanoma Graded Prognostic Assessment
Sperduto, Paul W. , Marqueen, Kathryn E. , Chang, Enoch , Li, Jing , Davies, Michael A. , Ebner, Daniel K. , Breen, William G. , Lamba, Nayan , Shih, Helen A. , Mahal, Amandeep R. , Rahman, Rifaquat , Ankrah, Nii, Boggs, Drexell H. , Lewis, Calvin D. , Hyer, Daniel E. , Johri, Fasila, Soliman, Hany , Masucci, Laura , Chiang, Veronica , Phuong, Christina , Dajani, Salah, Wan, Zihan, Niedzwiecki, Donna , Vaios, Eugene , Pasetsky, Jared , Wang, Tony J. C. , Kotecha, Rupesh , Ross, Richard B. , Rusthoven, Chad G. , Nakano, Toshimichi , Tawbi, Hussein A. , Edwards, Donna , Kim, Michelle M , Rahman, Rifaquat , Boggs, Drexell H , Lewis, Calvin , Hyer, Daniel , Buatti, John M , Aneja, Sanjay , Chiang, Veronica , Phuong, Christina , Braunstein, Steve , Sachdev, Sean , Niedzwiecki, Donna , Vaios, Eugene , Pasetsky, Jared , Wang, Tony J C , Kotecha, Rupesh , Ross, Richard B , Rusthoven, Chad G , Nakano, Toshimichi , Tawbi, Hussein , Mehta, Minesh P , Shih, Helen A , Kim, Michelle M. , Buatti, John M. , Roberge, David , Braunstein, Steve , Kirkpatrick, John P. , Kütük, Tuğçe , Mehta, Minesh P.

Journal of Clinical Oncology | April 17, 2025 | Volume: 43 | Issue: 16 | Pages: 1910-1919

10.1200/jco-24-01351 Get It

PURPOSE Survival for patients with melanoma has recently improved. The propensity of melanoma to metastasize to the brain remains a common and serious feature of this disease. The purposes of this study were to evaluate prognostic factors for patients with newly diagnosed melanoma brain metastases (MBMs) in a large cohort treated with modern multimodal therapies, compare those results with those in prior eras, and update the Melanoma Graded Prognostic Assessment (GPA). METHODS Univariable and multivariable (MVA) analyses of prognostic factors and treatments associated with survival were performed on 1,796 patients with newly diagnosed MBM treated between January 01, 2015, and December 31, 2021, using a multi-institutional retrospective database. Multiple imputation was used to address missingness of potential predictors. Significant variables in combined MVA were used to update the Melanoma GPA. Comparisons were made with legacy cohorts. RESULTS Median survivals for cohorts A (1985-2007, n = 481), B (2006-2015, n = 823), and C (2015-2021, n = 1,796) were 6.7, 9.8, and 16.6 months and median follow-up times were 40.1, 43.6, and 48.8 months, respectively. In combined MVA, significant prognostic factors for survival were higher Karnofsky Performance Status, fewer MBMs, absence of extracranial metastases, lower serum lactate dehydrogenase, and no immunotherapy before MBM. These factors were incorporated into the updated Melanoma GPA. The combined median and 3-year survivals for patients with GPA 0-1, 1.5-2, and 2.5-4.0 were 5.4, 13.2, and 43.2 months and 12.4%, 28.8%, and 51.6%, respectively. CONCLUSION Prognostic factors have changed and survival has improved for patients with MBM but varies widely by GPA. The updated Melanoma GPA calculator (BrainMetGPA), available free online, can be used to estimate survival, individualize treatment, stratify clinical trials, guide surveillance, and augment clinical trial eligibility. Multidisciplinary treatment is essential. Trials are needed to elucidate the optimal sequencing of various therapeutic modalities.
Proton therapy needs further technological development to fulfill the promise of becoming a superior treatment modality (compared to photon therapy)
Hyer, Daniel E. , Ding, Xuanfeng , Rong, Yi , Rong, Yi , Hyer, Daniel

Journal of Applied Clinical Medical Physics | November 3, 2021 | Volume: 22 | Issue: 11 | Pages: 4-11

10.1002/acm2.13450 Get It

Future mainstream platform for online adaptive radiotherapy will be using on‐board MR rather than on‐board (CB) CT images
Hyer, Daniel E. , Cai, Bin , Rong, Yi , Rong, Yi , Hyer, Daniel

Journal of Applied Clinical Medical Physics | July 19, 2021 | Volume: 22 | Issue: 7 | Pages: 4-9

10.1002/acm2.13352 Get It

An organ and effective dose study of XVI and OBI cone‐beam CT systems
Hyer, Daniel E. , Serago, Christopher F., Li, Jonathan G. , Hintenlang, David E., Kim, Siyong , Hyer, Daniel

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 11 | Issue: 2 | Pages: 181-197

10.1120/jacmp.v11i2.3183 Get It

The main purpose of this work was to quantify patient organ doses from the two kilovoltage cone beam computed tomography (CBCT) systems currently available on medical linear accelerators, namely the X‐ray Volumetric Imager (XVI, Elekta Oncology Systems) and the On‐Board Imager (OBI, Varian Medical Systems). Organ dose measurements were performed using a fiber‐optic coupled (FOC) dosimetry system along with an adult male anthropomorphic phantom for three different clinically relevant scan sites: head, chest, and pelvis. The FOC dosimeter was previously characterized at diagnostic energies by Hyer et al. [Med Phys 2009;36(5):1711–16] and a total uncertainty of approximately 4% was found for in‐phantom dose measurements. All scans were performed using current manufacturer‐installed clinical protocols and appropriate bow‐tie filters. A comparison of image quality between these manufacturer‐installed protocols was also performed using a Catphan 440 image quality phantom. Results indicated that for the XVI, the dose to the lens of the eye (1.07 mGy) was highest in a head scan, thyroid dose (19.24 mGy) was highest in a chest scan, and gonad dose (29 mGy) was highest in a pelvis scan. For the OBI, brain dose (3.01 mGy) was highest in a head scan, breast dose (5.34 mGy) was highest in a chest scan, and gonad dose (34.61 mGy) was highest in a pelvis scan. Image quality measurements demonstrated that the OBI provided superior image quality for all protocols, with both better spatial resolution and low‐contrast detectability. The measured organ doses were also used to calculate a reference male effective dose to allow further comparison of the two machines and imaging protocols. The head, chest, and pelvis scans yielded effective doses of 0.04, 7.15, and 3.73 mSv for the XVI, and 0.12, 1.82, and 4.34 mSv for the OBI, respectively.PACS number: 87.57.uq