Abstract Objectives Protein-truncating variants in the TTN gene are a well-established cause of dilated cardiomyopathy (DCM). We report a novel case of DCM caused by a mobile element insertion (MEI) in TTN, through which we highlight the key features of MEIs in next-generation sequencing data. Because of the rarity of MEIs, the next-generation sequencing data features associated with these events may be mistaken as noise, potentially leading to missed diagnoses. Methods Next-generation sequencing gene panel testing for DCM was performed on a 17-year-old male patient presenting with severe left ventricular dilatation and systolic dysfunction. Manta was used for structural variant detection, followed by manual review of NGS data for potential structural variants. Results Manta detected a potential insertion in TTN. Manual review identified hallmark features consistent with a LINE-1 MEI. This finding was orthogonally confirmed by long-range polymerase chain reaction and gel electrophoresis, which indicated an insertion of approximately 4 to 5 kilobase pairs. The insertion disrupted the reading frame of TTN within an A-band exon, resulting in protein truncation that was classified as likely pathogenic. Conclusions This case expands the mutational spectrum of TTN protein-truncating variants. It also underscores the importance of recognizing rarer types of pathogenic variants (eg, MEIs) to produce accurate genetic diagnostics.
Accurate and Automated Genotyping of the CFTR Poly-T/TG Tract with CFTR-TIPS
Cystic fibrosis is caused by biallelic pathogenic variants in the CFTR gene, which contains a polymorphic (TG)mTn sequence (the “poly-T/TG tract”) in intron 9. While T9 and T7 alleles are benign, T5 alleles with longer TG repeats, e.g., (TG)12T5 and (TG)13T5, are clinically significant. Thus, professional medical societies currently recommend reporting the TG repeat size when T5 is detected. Sanger sequencing is a cost-effective method of genotyping the (TG)mTn tract; however, its polymorphic length substantially complicates data analysis. We developed CFTR-TIPS, a freely available web-based software tool that infers the (TG)mTn genotype from Sanger sequencing data. This tool detects the (TG)mTn tract in the chromatograms, quantifies goodness of fit with expected patterns, and visualizes the results in a graphical user interface. It is broadly compatible with any Sanger chromatogram that contains the (TG)mTn tract ± 15 bp. We evaluated CFTR-TIPS using 835 clinical samples previously analyzed in a CLIA-certified, CAP-accredited laboratory. When operated fully automatically, CFTR-TIPS achieved 99.8% concordance with our clinically validated manual workflow, while generally taking less than 10 s per sample. There were two discordant samples: one due to a co-occurring heterozygous duplication that confounded the tool and the other due to incomplete (TG)mTn tract detection in the reverse chromatogram. No clinically significant misclassifications were observed. CFTR-TIPS is a free, accurate, and rapid tool for CFTR (TG)mTn tract genotyping using cost-effective Sanger sequencing. This tool is suitable both for automated use and as an aid to manual review to enhance accuracy and reduce analysis time.