AbstractBackgroundAscertaining involvement of left ventricular assist device (LVAD) in a patient presenting with bloodstream infection (BSI) can be challenging, frequently leading to use of chronic antimicrobial suppressive (CAS) therapy. We aimed to assess the efficacy of CAS therapy to prevent relapse of BSI from LVAD and non-LVAD sources.MethodsWe retrospectively screened adults receiving LVAD support from 2010 through 2018, to identify cases of BSI. Bloodstream infection events were classified into LVAD-related, LVAD-associated, and non-LVAD BSIs.ResultsA total of 121 episodes of BSI were identified in 80 patients. Of these, 35 cases in the LVAD-related, 14 in the LVAD-associated, and 46 in the non-LVAD BSI groups completed the recommended initial course of therapy and were evaluated for CAS therapy. Chronic antimicrobial suppressive therapy was prescribed in most of the LVAD-related BSI cases (32 of 35, 91.4%) and 12 (37.5%) experienced relapse. Chronic antimicrobial suppressive therapy was not prescribed in a majority of non-LVAD BSI cases (33, 58.9%), and most (31, 93.9%) did not experience relapse. Chronic antimicrobial suppressive therapy was prescribed in 9 of 14 (64.2%) cases of LVAD-associated BSI and none experienced relapse. Of the 5 cases in this group that were managed without CAS, 2 had relapse.ConclusionsPatients presenting with LVAD-related BSI are at high risk of relapse. Consequently, CAS therapy may be a reasonable approach in the management of these cases. In contrast, routine use of CAS therapy may be unnecessary for non-LVAD BSIs.
Invasive Pulmonary Aspergillosis in Patients with SARS-CoV-2 Infection: A Systematic Review of the Literature
In this systematic review, we investigate the epidemiology, pathogenesis, risk factors, clinical manifestations, diagnosis and treatment of COVID-19-associated pulmonary aspergillosis (CAPA). We identified 85 cases from 22 studies. The frequency of CAPA is currently unknown but ranges between <5% to >30% in different case series; the possibility of colonization rather than invasive disease is the most important confounder. The vast majority of patients with CAPA did not have any of the classic host risk factors, such as immunosuppression from organ transplant or neutropenia, although a significant proportion (46%) had received corticosteroids. Age, pulmonary comorbidities and male sex were associated with higher mortality. Patients treated with voriconazole had numerically lower case-fatality rate. Clinical vigilance for CAPA is advisable in critically ill patients with COVID-19 who are not improving, even those who do not meet classic host criteria for invasive mycoses, especially if they are receiving corticosteroids. A thorough, multi-faceted diagnostic work-up and early initiation of a mold-active triazole may be lifesaving. Further research studies using standardized, uniform definitions of invasive disease and colonization are urgently needed.
Management and Outcome of Left Ventricular Assist Device Infections in Patients Undergoing Cardiac Transplantation
Abstract Background Post-operative management of patients undergoing cardiac transplantation with an infected left ventricular assist device (LVAD) is unclear. Methods We retrospectively screened all adults with an LVAD who underwent cardiac transplantation at our institution from 2010 through 2018. We selected all cases of LVAD-specific and LVAD-related infections who were receiving antimicrobial therapy as initial treatment course or chronic suppression at the time of cardiac transplantation. Non-LVAD infections, superficial driveline-infection, or concurrent use of right ventricular assist device or extracorporeal membrane oxygenation device were excluded. Results A total of 54 cases met study criteria with 18/54 (33.6%) classified as LVAD- specific or related infections and 36/54 (66.6%) as non-infected. Cases of LVAD-infection had a higher median Charlson Comorbidity Index score at the time of transplantation compared to non-infected cases (P=.005). Of the 18 cases of infection, 13/18 (72.2%) were classified as LVAD-specific and 5/18 (27.8%) as LVAD-related. A total of 9/13 (69.2%) cases had proven LVAD-specific infections. Antimicrobial therapy was extended post-transplant to treat preceding LVAD-specific infection in all nine cases (9/13, 69.2%) with a median duration of 14 days (IQR 14-28). Following LVAD removal, antimicrobial treatment was not continued for preceding LVAD-related infections. Conclusions Patients with an LVAD-specific infection were treated with two weeks of pathogen-directed therapy post heart transplant without any relapses. For those without LVAD-specific infection or uncomplicated LVAD-related bacteremia who had completed antimicrobial therapy pre-transplant, antibiotics were discontinued after standard peri-operative prophylaxis and no relapses were observed.
Discriminative Ability and Reliability of Transesophageal Echocardiography in Characterizing Cases of Cardiac Device Lead Vegetations Versus Noninfectious Echodensities
Abstract Background Approximately one-third of cases of cardiovascular implantable electronic device (CIED) infection present as CIED lead infection. The precise transesophageal echocardiographic (TEE) definition and characterization of “vegetation” associated with CIED lead infection remain unclear. Methods We identified a sample of 25 consecutive cases of CIED lead infection managed at our institution between January 2010 and December 2017. Cases of CIED lead infection were classified using standardized definitions. Similarly, a sample of 25 noninfected patients who underwent TEE that showed a defined lead echodensity during the study period was included as a control group. TEEs were reviewed by 2 independent echocardiologists who were blinded to all linked patient demographic, clinical, and microbiological information. Reported echocardiographic variables of the infected vs noninfected cases were compared, and the overall diagnostic performance was analyzed. Results Descriptions of lead echodensities were variable and there were no significant differences in median echodensity diameter or mobility between infected vs noninfected groups. Among infected cases, blinded echocardiogram reports by either reviewer correctly made a prediction of infection in 6 of 25 (24%). Interechocardiologist agreement was 68%. Sensitivity of blinded TEEs ranged from 31.5% to 37.5%. Conclusions Infectious vs noninfectious lead echodensities could not be reliably distinguished on the basis of size, mobility, and general shape descriptors obtained from a retrospective blinded TEE examination without knowledge of clinical and microbiological parameters. Therefore, a reanalysis of criteria used to support a diagnosis of CIED lead infection may be warranted.
2676. Effect of β-Lactam Allergy on Appropriateness of Antibiotic Use in Patients with Febrile Neutropenia
Abstract Background Over 80% of patients with hematologic malignancies develop some form of infectious complication, most commonly febrile neutropenia. Patients with febrile neutropenia have 10% mortality, which increases if antibiotic administration is delayed past 30 minutes. Studies have suggested β-lactam allergy may delay administration of antibiotic while putting patients at greater risk for inappropriate antibiotic choice and adverse effects stemming from this. We sought to describe the risks associated with β-lactam allergy in the neutropenic population. Methods We conducted a retrospective, descriptive study from January 2016 to December 2017 identifying patients with febrile neutropenia and a reported history of β-lactam allergy. Baseline characteristics, allergy data, treatment data, and outcomes were collected and analyzed. Results We identified 31 patients with febrile neutropenia and β-lactam allergy during this time period. Etiologies of neutropenia were hematologic malignancy (61.2%), stem cell transplantation (12.9%), solid-organ malignancy (22.6%), and autoimmune (3.3%). Reported reactions to β-lactams were rash (41.9%), hives (9.7%), anaphylaxis (3.2%), other (9.7%), and unknown (35.5%). Average time to antibiotic administration was 142.5 minutes. Antibiotic choice was cefepime (61.3%), piperacillin–tazobactam (6.5%), carbapenem (22.6%), fluoroquinolone (6.5%), cefepime and fluoroquinolone (3.2%), and vancomycin (58.1%). 51.6% received initial antibiotics consistent with the 2010 IDSA guidelines. Six patients underwent penicillin skin testing, all negative. 1 patient developed C. difficile infection, 1 developed MRSA colonization, and 3 developed VRE colonization. Mortality was 3.2% at 30 days and 16.1% at 90 days. Conclusion Our study estimated the antibiotic usage patterns and outcomes in patients with febrile neutropenia and reported β-lactam allergy. This showed low adherence to an established guideline for antibiotic choice in these patients. With rising antimicrobial resistance, there is a need to develop strategies to reduce inappropriate antimicrobial use, especially in patients with febrile neutropenia. Preemptive β-lactam allergy evaluation warrants further evaluation in the neutropenic population. Disclosures All authors: No reported disclosures.
660. Extraction-Free 16S Ribosomal RNA (rRNA) Gene Amplification and Sequencing from Resected Cardiac Implantable Electronic Device (CIED) Sonicate Fluid
Abstract Background We recently demonstrated that 16S rRNA PCR/sequencing performed on biofilms dislodged from extracted CIEDs into a salt solution—referred to as “sonicate fluid’ (SF)—may be used to detect pathogens in culture-negative CIED infection (Clinical Infectious Diseases, ciz266, doi:10.1093/cid/ciz266). The method we described included a DNA extraction/purification step, which can be time consuming and costly. Here, we evaluated an extraction-free approach to 16S rRNA gene PCR/sequencing. Methods 28 SF samples derived from explanted clinically-infected CIEDs were tested. Cases were categorized as “culture-positive” (C-P) if ≥20 cfu/10 mL were recovered, and as “culture-negative” (C-N), if <20 cfu/10 mL were detected in SF culture. The extraction-free method consisted of a single step of lysis at 1,000 rpm, 95°C for 5 minutes using an Eppendorf ThermoMixer®. DNA extraction (the comparator method) was performed using the ZymoBIOMICSTM Kit with modifications. Samples were processed using both methods, followed by amplification of the 16S rRNA gene and bidirectional Sanger sequencing. Crossing points (CPs) generated by the two approaches were compared. Organisms detected by the two PCR methods were compared with those detected with culture. Results Of the 28 samples tested, 13 were C-N and 15 C-P. The extraction-free method generated an amplicon in 13/15 C-P cases, with CPs ranging from 26 to 36 cycles vs. 100% (15/15) detected with the DNA extraction method and Cps of 19 to 32. Usable sequence length for the extraction-free method was of 359 (interquartile range, 307–390) vs. 390 (interquartile range, 308–396) base pairs with DNA extraction. Genus-level concordance between bacteria detected by culture in C-P samples and those found using the extraction-free and extraction methods was 92% (12/13) and 93% (14/15), respectively. Bacteria were detected by the extraction method in 2/13 C-N specimens, with none detected with an extraction-free method. Conclusion The described extraction-free method may be suitable for testing SF derived from CIEDs using 16S rRNA gene PCR/sequencing, saving time and cost. More studies are needed to establish clear cutoffs for interpretation of results and to assess for PCR inhibitors in the studied specimen-type. Disclosures Robin Patel, MD, ASM and IDSA: Other Financial or Material Support, Travel reimbursement, editor’s stipends; CD Diagnostics, Merck, Hutchison Biofilm Medical Solutions, Accelerate Diagnostics, ContraFect, TenNor Therapeutics Limited, Shionogi: Grant/Research Support; Curetis, Specific Technologies, NextGen Diagnostics, PathoQuest, Qvella: Consultant; NBME, Up-to-Date, the Infectious Diseases Board Review Course: Honorarium recipient, Other Financial or Material Support; Patent on Bordetella pertussis/parapertussis PCR issued, a patent on a device/method for sonication with royalties paid by Samsung to Mayo Clinic, and a patent on an anti-biofilm substance issued: Other Financial or Material Support, Patents.
Molecular Approach to Diagnosis of Cardiovascular Implantable Electronic Device Infection
Abstract Background Sonicate fluid (SF), a solution derived from vortexing and sonication of explanted cardiovascular implantable electronic devices (CIEDs), is a higher-yield specimen compared with swabs or tissues for culture-based detection of microorganisms associated with CIED infection. Despite this, SF culture fails to identify a causative organism in ~50% of cases. We aimed to evaluate the diagnostic performance of 16S ribosomal RNA gene (rRNA) polymerase chain reaction (PCR)/sequencing of SF and compare it with that of SF culture. Methods We identified 322 SF specimens from extracted CIEDs and reviewed clinical data for each patient. Subjects were classified as having or not having CIED infection. Cases were subcategorized as culture negative if no significant growth was reported from SF cultures and as culture positive if an organism was detected above predefined thresholds. 16S rRNA PCR/sequencing was performed, with the organisms identified reported according to Clinical and Laboratory Standards Institute guidelines for sequence data interpretation. Results A total of 278 SF samples corresponded to infected cases, of which 160 were culture positive and 118 culture negative. The remaining 44 were from noninfected cases, of which 2 were culture positive. Compared with SF culture, the sensitivity of 16S rRNA PCR/sequencing was higher (64% vs 57.5%, P = .003). 16S rRNA PCR/sequencing detected a potential pathogen in 28 of 118 culture-negative cases, identifying staphylococci in the majority (18/28). Conclusions 16S rRNA PCR/sequencing has higher sensitivity to detect bacteria in SF from extracted CIEDs than does SF culture.
Postoperative Hardware-Related Infection from Kytococcus schroeteri: Its Association with Prosthetic Material and Hematological Malignancies—A Report of a Case and Review of Existing Literature
Introduction. Kytococcus schroeteri is an infrequently isolated Gram-positive coccus often encountered as a commensal bacterium. Only eighteen cases of human infection associated with this organism have been previously reported. Most of these cases involved patients with implanted prosthetic materials or patients with immunosuppressive conditions. It has been described in prosthetic valve endocarditis and in select patients with hematologic diseases but only one prior report as being involved in osteoarticular infections. Case Presentation. We describe a case of postsurgical osteoarticular hardware-related infection by K. schroeteri and discuss a possible association with implanted prosthetic material. Conclusion. Other clinical presentations of K. schroeteri, including reported infection syndromes, antimicrobial susceptibility profiles, and treatment outcomes, are also reviewed.
Predictors of Bloodstream Infection in Patients Presenting With Cardiovascular Implantable Electronic Device Pocket Infection
2029. Comparison of Primers Amplifying Two Different Regions of the 16S Ribosomal RNA Gene for Microbiologic Diagnosis of Cardiovascular Implantable Electronic Device Infection