Back to Authors

Greenleaf, James F.

https://orcid.org/0000-0003-1629-8203

Mayo Clinic

Mayo Clinic

Citations 125

An ultrasound surface wave elastography technique for noninvasive measurement of surface lung tissue
Osborn, Thomas G. , Greenleaf, James F. , Kalra, Sanjay , Zhang, Xiaoming , Zhou, Boran , Bartholmai, Brian J.

The Journal of the Acoustical Society of America | June 10, 2017 | Volume: 141 | Issue: 5_Supplement | Pages: 3721-3721

10.1121/1.4988149 Get It

Ultrasonography is not widely used in clinic for lung assessment because ultrasound cannot image deep lung tissue. In this abstract, we present a novel technique, lung ultrasound surface wave elastography (LUSWE), for measuring the elastic properties of superficial lung tissue. In LUSWE, a small, local, and 0.1 second harmonic vibration is generated on the chest of a subject. The speed of surface wave on the lung is measured by using an ultrasound probe. We are evaluating LUSWE for assessing patients with interstitial lung disease (ILD). LUSWE may be useful for assessing ILD because most ILD patients have typical fibrotic scars in the peripheral and subpleural regions of the lung. In a large clinical study of ILD patients, we measure both lungs through six intercostal spaces for patients and controls. The surface wave speed is measured at 100 Hz, 150 Hz, and 200 Hz. In an example, the surface wave speed is 1.88 ± 0.11 m/s and 3.3 ± 0.37 m/s, respectively, for a healthy subject and an ILD patient at 100 Hz and in the same intercostal space. LUSWE may compliment the clinical standard high-resolution computed tomography for assessing ILD. LUSWE may be useful for assessing other lung disorders.
Measurement of tissue viscoelasticity with ultrasound
Greenleaf, James F. , Alizad, Azra

SPIE Proceedings | February 28, 2017 | Volume: 10067 | Issue: No issue available | Pages: 1006705

10.1117/12.2256842 Get It

Attenuation measuring ultrasound shearwave elastography and in vivo application in post-transplant liver patients
Nenadic, Ivan , Qiang, Bo, Zhao, Heng , Sánchez, William , Greenleaf, James F. , Chen, Shigao , Nenadic, Ivan Z, Urban, Matthew W. , Sanchez, William

Physics in Medicine & Biology | December 21, 2016 | Volume: 62 | Issue: 2 | Pages: 484-500

10.1088/1361-6560/aa4f6f Get It

Abstract Ultrasound and magnetic resonance elastography techniques are used to assess mechanical properties of soft tissues. Tissue stiffness is related to various pathologies such as fibrosis, loss of compliance, and cancer. One way to perform elastography is measuring shear wave velocity of propagating waves in tissue induced by intrinsic motion or an external source of vibration, and relating the shear wave velocity to tissue elasticity. All tissues are inherently viscoelastic and ignoring viscosity biases the velocity-based estimates of elasticity and ignores a potentially important parameter of tissue health. We present attenuation measuring ultrasound shearwave elastography (AMUSE), a technique that independently measures both shear wave velocity and attenuation in tissue and therefore allows characterization of viscoelasticity without using a rheological model. The theoretical basis for AMUSE is first derived and validated in finite element simulations. AMUSE is validated against the traditional methods for assessing shear wave velocity (phase gradient) and attenuation (amplitude decay) in tissue mimicking phantoms and excised tissue. The results agreed within one standard deviation. AMUSE was used to measure shear wave velocity and attenuation in 15 transplanted livers in patients with potential acute rejection, and the results were compared with the biopsy findings in a preliminary study. The comparison showed excellent agreement and suggests that AMUSE can be used to separate transplanted livers with acute rejection from livers with no rejection.
Low–Energy Shockwave Therapy Improves Ischemic Kidney Microcirculation
Zhang, Xin , Krier, James D., Carrascal, Carolina Amador, Greenleaf, James F. , Hedayat, Ahmad F. , Textor, Stephen C., Lerman, Lilach O. , Carrascal, Carolina Amador, Ebrahimi, Behzad , Lerman, Amir

Journal of the American Society of Nephrology | June 13, 2016 | Volume: 27 | Issue: 12 | Pages: 3715-3724

10.1681/asn.2015060704 Get It

Microvascular rarefaction distal to renal artery stenosis is linked to renal dysfunction and poor outcomes. Low–energy shockwave therapy stimulates angiogenesis, but the effect on the kidney microvasculature is unknown. We hypothesized that low–energy shockwave therapy would restore the microcirculation and alleviate renal dysfunction in renovascular disease. Normal pigs and pigs subjected to 3 weeks of renal artery stenosis were treated with six sessions of low–energy shockwave (biweekly for 3 consecutive weeks) or left untreated. We assessed BP, urinary protein, stenotic renal blood flow, GFR, microvascular structure, and oxygenation in vivo 4 weeks after completion of treatment, and then, we assessed expression of angiogenic factors and mechanotransducers (focal adhesion kinase and β 1-integrin) ex vivo . A 3-week low–energy shockwave regimen attenuated renovascular hypertension, normalized stenotic kidney microvascular density and oxygenation, stabilized function, and alleviated fibrosis in pigs subjected to renal artery stenosis. These effects associated with elevated renal expression of angiogenic factors and mechanotransducers, particularly in proximal tubular cells. In additional pigs with prolonged (6 weeks) renal artery stenosis, shockwave therapy also decreased BP and improved GFR, microvascular density, and oxygenation in the stenotic kidney. This shockwave regimen did not cause detectable kidney injury in normal pigs. In conclusion, low–energy shockwave therapy improves stenotic kidney function, likely in part by mechanotransduction-mediated expression of angiogenic factors in proximal tubular cells, and it may ameliorate renovascular hypertension. Low–energy shockwave therapy may serve as a novel noninvasive intervention in the management of renovascular disease.
Phase Aberration and Attenuation Effects on Acoustic Radiation Force-Based Shear Wave Generation
Amador, Carolina , Aristizabal, Sara , Greenleaf, James F. , Urban, Matthew W.

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control | January 6, 2016 | Volume: 63 | Issue: 2 | Pages: 222-232

10.1109/tuffc.2016.2515366 Get It

Investigation of the effects of myocardial anisotropy for shear wave elastography using impulsive force and harmonic vibration
Qiang, Bo, Song, Pengfei , Nenadic, Ivan , Chen, Shigao , Greenleaf, James F. , Urban, Matthew W. , Nenadic, Ivan Z, Song, Pengfei

Physics in Medicine & Biology | December 16, 2015 | Volume: 61 | Issue: 1 | Pages: 365-382

10.1088/0031-9155/61/1/365 Get It

Abstract The myocardium is known to be an anisotropic medium where the muscle fiber orientation changes through the thickness of the wall. Shear wave elastography methods use propagating waves which are measured by ultrasound or magnetic resonance imaging (MRI) techniques to characterize the mechanical properties of various tissues. Ultrasound- or MR-based methods have been used and the excitation frequency ranges for these various methods cover a large range from 24–500 Hz. Some of the ultrasound-based methods have been shown to be able to estimate the fiber direction. We constructed a model with layers of elastic, transversely isotropic materials that were oriented at different angles to simulate the heart wall in systole and diastole. We investigated the effect of frequency on the wave propagation and the estimation of fiber direction and wave speeds in the different layers of the assembled models. We found that waves propagating at low frequencies such as 30 or 50 Hz showed low sensitivity to the fiber direction but also had substantial bias in estimating the wave speeds in the layers. Using waves with higher frequency content (>200 Hz) allowed for more accurate fiber direction and wave speed estimation. These results have particular relevance for MR- and ultrasound-based elastography applications in the heart.
Characterization of material properties of soft solid thin layers with acoustic radiation force and wave propagation
Nenadic, Ivan , Qiang, Bo, Chen, Shigao , Greenleaf, James F. , Urban, Matthew W. , Nenadic, Ivan Z, Bernal, Miguel

The Journal of the Acoustical Society of America | October 28, 2015 | Volume: 138 | Issue: 4 | Pages: 2499-2507

10.1121/1.4932170 Get It

Evaluation of tissue engineering constructs is performed by a series of different tests. In many cases it is important to match the mechanical properties of these constructs to those of native tissues. However, many mechanical testing methods are destructive in nature which increases cost for evaluation because of the need for additional samples reserved for these assessments. A wave propagation method is proposed for characterizing the shear elasticity of thin layers bounded by a rigid substrate and fluid-loading, similar to the configuration for many tissue engineering applications. An analytic wave propagation model was derived for this configuration and compared against finite element model simulations and numerical solutions from the software package Disperse. The results from the different models found very good agreement. Experiments were performed in tissue-mimicking gelatin phantoms with thicknesses of 1 and 4 mm and found that the wave propagation method could resolve the shear modulus with very good accuracy, no more than 4.10% error. This method could be used in tissue engineering applications to monitor tissue engineering construct maturation with a nondestructive wave propagation method to evaluate the shear modulus of a material.
Simulation of wave propagation in anisotropic and viscoelastic tissues
Qiang, Bo, Aristizabal, Sara , Nenadic, Ivan , McGough, Robert J., Greenleaf, James F. , Urban, Matthew W. , Song, Pengfei , Chen, Shigao

The Journal of the Acoustical Society of America | October 14, 2015 | Volume: 138 | Issue: 3_Supplement | Pages: 1906-1906

10.1121/1.4933994 Get It

Many methods for characterization of the mechanical properties of soft tissues using propagating shear waves have been developed over the past two decades. Most of these methods assume that the shear wave is traveling in an elastic, isotropic tissue. However, many soft tissues are viscoelastic and have material properties that are directionally dependent or anisotropic. We have been developing methods to measure waves propagating in soft tissues to estimate the anisotropic viscoelastic material properties. To refine our measurement methods, we have also developed techniques and models for simulating the wave propagation in these types of materials. We have developed specialized finite element and pseudo-spectral models that can simulate viscoelastic transversely isotropic materials and compared our results with measurements in ex vivo porcine muscle. Additionally, we have developed a finite element model that simulates wave propagation in the myocardium by creating a model of layered transverse isotropic media oriented at different angles. We examined the effect of frequency of the waves for estimating of the angle of propagation. We compared these simulation results with experimental results from an ex vivo porcine left ventricular wall. These simulation methods provide insight for optimizing our measurement methods for in vivo characterization of material properties.
Simulation of ultrasound radiation force induced shear wave propagation in viscoelastic media using a mapped Chebyshev pseudospectral method
Qiang, Bo, McGough, Robert J., Greenleaf, James F. , Brigham, John C. , Urban, Matthew W.

Journal of the Acoustical Society of America | May 1, 2015 | Volume: 137 | Issue: 4_Supplement | Pages: 2364-2364

10.1121/1.4920589 Get It

We implemented a three-dimensional solver for simulating the ultrasound radiation force induced shear wave motion in viscoelastic media using a mapped Chebyshev pseudospectral method. The solver used a body force field that is simulated by the Field II program as the excitation. Then, a velocity-stress formulation was used to calculate the shear wave motion. We used a Voigt model to describe tissue viscoelasticity, and the viscosity is introduced by memory variables and auxiliary differential equations. The top boundary of the domain had a fixed boundary condition to mimic the interaction between an ultrasound probe and the tissue surface. All other sides of the domain were surrounded by perfectly matched layers to minimize the reflections. Time stepping was implemented with the LSODE integrator with variable step sizes. Results show that the waveform of the simulated shear wave is close to experimental observations and equivalent FEM simulations. We used a Fourier-based method to estimate the phase velocities of the shear waves between 100–1000 Hz and a nonlinear regression to estimate the Voigt model parameters. The reconstructions matched within 10% error compared with the true values.
Characterization of anisotropic media with shear waves
Aristizabal, Sara , Qiang, Bo, Amador, Carolina , Kinnick, Randall R., Greenleaf, James F. , Urban, Matthew W. , Brigham, John C. , Zhang, Xiaoming

The Journal of the Acoustical Society of America | October 18, 2014 | Volume: 136 | Issue: 4_Supplement | Pages: 2124-2124

10.1121/1.4899649 Get It

In conventional shear wave elastography materials are assumed to be linear, elastic, homogeneous, and isotropic. These assumptions are important to account for in certain tissues because they are not always appropriate. Many tissues such as skeletal muscle, the kidney, and the myocardium are anisotropic. Shear waves can be used to investigate the directionally dependent mechanical properties of anisotropic media. To study these tissues in a systematic way and to account for the effects of the anisotropic architecture, laboratory-based phantoms are desirable. We will report on several phantom-based approaches for studying shear wave anisotropy, assuming that these materials are transversely isotropic. Phantoms with embedded fibers were used to mimic anisotropic tissues. Homogeneous phantoms were compressed to induce transverse isotropy according to the acoustoelastic phenomenon, which is related to nonlinear behavior of the materials. The fractional anisotropy of these phantoms was quantified to compare with measurements made in soft tissues. In addition, soft tissues are also viscoelastic, and we have developed a method to model viscoelastic transversely isotropic materials with the finite element method (FEM). The viscoelastic property estimation from phantom experiments and FEM simulations will also be discussed.