Abstract Objective . Arterial dispersion ultrasound vibrometry (ADUV) relies on the use of guided waves in arterial geometries for shear wave elastography measurements. Both the generation of waves through the use of acoustic radiation force (ARF) and the techniques employed to infer the speed of the resulting wave motion affect the spectral content and accuracy of the measurement. In particular, the effects of the shape and location of the ARF beam in ADUV have not been widely studied. In this work, we investigated how such variations of the ARF beam affect the induced motion and the measurements in the dispersive modes that are excited. Approach. The study includes an experimental evaluation on an arterial phantom and an in vivo validation of the observed trends, observing the two walls of the waveguide, simultaneously, when subjected to variations in the ARF beam extension ( F / N ) and focus location. Main results. Relying on the theory of guided waves in cylindrical shells, the shape of the beam controls the selection and nature of the induced modes, while the location affects the measured dispersion curves (i.e. variation of phase velocity with frequency or wavenumber, multiple modes) across the waveguide walls. Significance. This investigation is important to understand the spectral content variations in ADUV measurements and to maximize inversion accuracy by tuning the ARF beam settings in clinical applications.
Novel Uses of Ultrasound to Assess Kidney Mechanical Properties
Ultrasound is a key imaging tool for evaluating the kidney. Over the last two decades, methods to measure the mechanical properties of soft tissues have been developed and used in clinical practice, although use in the kidney has not been as widespread as for other applications. The mechanical properties of the kidney are determined by the structure and composition of the renal parenchyma and perfusion characteristics. Because pathologic processes change these factors, the mechanical properties change and can be used for diagnostic purposes and for monitoring treatment or disease progression. Ultrasound-based elastography methods for evaluating the mechanical properties of the kidney use focused ultrasound beams to perturb the kidney and then high frame-rate ultrasound methods are used to measure the resulting motion. The motion is analyzed to estimate the mechanical properties. This review will describe the principles of these methods and discuss several seminal studies related to characterizing the kidney. Additionally, an overview of the clinical use of elastography methods in native and kidney allografts will be provided. Perspectives on future developments and uses of elastography technology along with other complementary ultrasound imaging modalities will be provided.
Multimodal guided wave inversion for arterial stiffness: methodology and validation in phantoms
Abstract Arterial stiffness is an important biomarker for many cardiovascular diseases. Shear wave elastography is a recent technique aimed at estimating local arterial stiffness using guided wave inversion (GWI), i.e. matching the computed and measured wave dispersion. This paper develops and validates a new GWI approach by synthesizing various recent observations and algorithms: (a) refinements to signal processing to obtain more accurate experimental dispersion curves; (b) an efficient forward model to compute theoretical dispersion curves for immersed, incompressible cylindrical waveguides; (c) an optimization framework based on the recent observation that the measured dispersion curve is multimodal, i.e. it matches for not one but two different wave modes in two different frequency ranges. The resulting inversion approach is validated using extensive experimental data from rubber tube phantoms, not only for modulus estimation but also to simultaneously estimate modulus and wall thickness. The observations indicate that the modulus estimates are best performed with the information on wall thickness. The approach, which takes less than half a minute to run, is shown to be accurate, with the modulus estimated with less than 4% error for 70% of the experiments.
We report a technique, named optical coherence viscometry (OCV), to measure the viscosity of Newtonian fluids in a noncontact manner. According to linear wave theory with small amplitudes, capillary waves are associated with fluid mechanical properties. To perform this measurement and avoid the overdamped effects of capillary waves in viscous fluids, transient acoustic radiation force was applied to generate capillary waves. Within a very limited field-of-view using optical coherence tomography, wave motion acquired in the time domain was analyzed using Fourier methods to study the wave velocity dispersion and attenuation relationships for capillary waves, which can reduce the fluid quantity drastically into tissue culture scale. We measure the viscosities of water, water–glycerol solutions with three concentrations, and biological plasma using the proposed OCV and compare the experimental results to theoretical calculations. OCV is sensitive to wave perturbations and can be a promising technique for measuring the viscosity of biological fluids and could be applied in future applications for measurements for lipid membranes in cell biology and tissue engineering investigation.
Two-dimensional (2D) dynamic vibration optical coherence elastography (DV-OCE) for evaluating mechanical properties: a potential application in tissue engineering
Mechanical properties in tissues are an important indicator because they are associated with disease states. One of the well-known excitation sources in optical coherence elastography (OCE) to determine mechanical properties is acoustic radiation force (ARF); however, a complicated focusing alignment cannot be avoided. Another excitation source is a piezoelectric (PZT) stack to obtain strain images via compression, which can affect the intrinsic mechanical properties of tissues in tissue engineering. In this study, we report a new technique called two-dimensional (2D) dynamic vibration OCE (DV-OCE) to evaluate 2D wave velocities without tedious focusing alignment procedures and is a non-contact method with respect to the samples. The three-dimensional (3D) Fourier transform was utilized to transfer the traveling waves (x, y, t) into 3D k-space (kx, ky, f). A spatial 2D wavenumber filter and multi-angle directional filter were employed to decompose the waves with omni-directional components into four individual traveling directions. The 2D local wave velocity algorithm was used to calculate a 2D wave velocity map. Six materials, two homogeneous phantoms with 10 mm thickness, two homogeneous phantoms with 2 mm thickness, one heterogeneous phantom with 2 mm diameter inclusion and an ex vivo porcine kidney, were examined in this study. In addition, the ARF-OCE was used to evaluate wave velocities for comparison. Numerical simulations were performed to validate the proposed 2D dynamic vibration OCE technique. We demonstrate that the experimental results were in a good agreement with the results from ARF-OCE (transient OCE) and numerical simulations. Our proposed 2D dynamic vibration OCE could potentially pave the way for mechanical evaluation in tissue engineering and for laboratory translation with easy-to-setup and contactless advantages.
Radiological Society of North America/Quantitative Imaging Biomarker Alliance Shear Wave Speed Bias Quantification in Elastic and Viscoelastic Phantoms
ObjectivesTo quantify the bias of shear wave speed (SWS) measurements between different commercial ultrasonic shear elasticity systems and a magnetic resonance elastography (MRE) system in elastic and viscoelastic phantoms.MethodsTwo elastic phantoms, representing healthy through fibrotic liver, were measured with 5 different ultrasound platforms, and 3 viscoelastic phantoms, representing healthy through fibrotic liver tissue, were measured with 12 different ultrasound platforms. Measurements were performed with different systems at different sites, at 3 focal depths, and with different appraisers. The SWS bias across the systems was quantified as a function of the system, site, focal depth, and appraiser. A single MRE research system was also used to characterize these phantoms using discrete frequencies from 60 to 500 Hz.ResultsThe SWS from different systems had mean difference 95% confidence intervals of ±0.145 m/s (±9.6%) across both elastic phantoms and ± 0.340 m/s (±15.3%) across the viscoelastic phantoms. The focal depth and appraiser were less significant sources of SWS variability than the system and site. Magnetic resonance elastography best matched the ultrasonic SWS in the viscoelastic phantoms using a 140 Hz source but had a − 0.27 ± 0.027‐m/s (−12.2% ± 1.2%) bias when using the clinically implemented 60‐Hz vibration source.ConclusionsShear wave speed reconstruction across different manufacturer systems is more consistent in elastic than viscoelastic phantoms, with a mean difference bias of < ±10% in all cases. Magnetic resonance elastographic measurements in the elastic and viscoelastic phantoms best match the ultrasound systems with a 140‐Hz excitation but have a significant negative bias operating at 60 Hz. This study establishes a foundation for meaningful comparison of SWS measurements made with different platforms.
Characterizing thrombus with multiple red blood cell compositions by optical coherence tomography attenuation coefficient
AbstractEmbolectomy is one of the emergency procedures performed to remove emboli. Assessing the composition of human blood clots is an important diagnostic factor and could provide guidance for an appropriate treatment strategy for interventional physicians. Immunostaining has been used to identity compositions of clots as a gold‐standard procedure, but it is time‐consuming and cannot be performed in situ. Here, we proposed that the optical attenuation coefficient of optical coherence tomography (OCT) can be a reliable indicator as a new imaging modality to differentiate clot compositions. Fifteen human blood clots with multiple red blood cell (RBC) compositions from 21% to 95% were prepared using healthy human whole blood. A homogeneous gelatin phantom experiment and numerical simulation based on the Lambert–Beer's law were examined to verify the validity of the attenuation coefficient estimation. The results displayed that optical attenuation coefficients were strongly correlated with RBC compositions. We reported that attenuation coefficients could be a promising biomarker to guide the choice of an appropriate interventional device in a clinical setting and assist in characterizing blood clots.
A parametric evaluation of shear wave speeds estimated with time-of-flight calculations in viscoelastic media
Shear wave elasticity imaging (SWEI) uses an acoustic radiation force to generate shear waves, and then soft tissue mechanical properties are obtained by analyzing the shear wave data. In SWEI, the shear wave speed is often estimated with time-of-flight (TOF) calculations. To characterize the errors produced by TOF calculations, three-dimensional (3D) simulated shear waves are described by time-domain Green's functions for a Kelvin-Voigt model evaluated for multiple combinations of the shear elasticity and the shear viscosity. Estimated shear wave speeds are obtained from cross correlations and time-to-peak (TTP) calculations applied to shear wave particle velocities and shear wave particle displacements. The results obtained from these 3D shear wave simulations indicate that TTP calculations applied to shear wave particle displacements yield effective estimates of the shear wave speed if noise is absent, but cross correlations applied to shear wave particle displacements are more robust when the effects of noise and shear viscosity are included. The results also show that shear wave speeds estimated with TTP methods and cross correlations using shear wave particle velocities are more sensitive to increases in shear viscosity and noise, which suggests that superior estimates of the shear wave speed are obtained from noiseless or noisy shear wave particle displacements.
Fluid surface tension evaluation using capillary wave measurement with optical coherence tomography
The surface tension of biological fluids is an important parameter because the mechanical properties of fluids are closely linked with hematological diseases and other pathophysiologies. Capillary waves are associated with fluid mechanical properties. Here, we propose a method that utilizes the acoustic radiation force (ARF) to generate propagating waves and optical coherence tomography (OCT) to measure the wave motion. This ARF-OCT method is capable of evaluating the surface tension of fluids, water and porcine whole blood in this study, based on the dispersion relation of capillary waves. Two-dimensional Fourier transforms were used to decompose frequency components of wave motion images to obtain a k-space representation and estimate the wave phase velocity. The phase velocity of capillary waves was obtained from the experimental results and compared to theoretical calculations. The surface tensions of water and porcine whole blood were determined from the experimental results. We first report that capillary waves measured with OCT can be a new promising modality for measuring the surface tension of fluids. The proposed method could be used to differentiate actual pathologic fluids or blood from those taken from healthy subjects and as a biomarker in future biomedical applications.