Back to Authors

Hall, Timothy J.

https://orcid.org/0000-0001-9850-6031

Mayo Clinic

University of Wisconsin System

Citations 3

A Force-Matched Approach to Large-Strain Nonlinearity in Elasticity Imaging for Breast Lesion Characterization
Rosen, David , Nayak, Rohit , Wang, Yuqi , Gendin, Daniel , Larson, Nicholas B. , Fazzio, Robert T. , Oberai, Assad A. , Hall, Timothy J. , Barbone, Paul E. , Hall, Timothy J , Rosen, David P , Larson, Nicholas B , Alizad, Azra , Fatemi, Mostafa

IEEE Transactions on Biomedical Engineering | August 17, 2023 | Volume: 71 | Issue: 1 | Pages: 367-374

10.1109/tbme.2023.3305986 Get It

Radiological Society of North America/Quantitative Imaging Biomarker Alliance Shear Wave Speed Bias Quantification in Elastic and Viscoelastic Phantoms
Palmeri, Mark L. , Milkowski, Andy , Barr, R. Graham , Carson, Paul L. , Couade, Mathieu , Chen, Shigao , Dhyani, Manish , Ehman, Richard L. , Garra, Brian S. , Gee, Albert, Guenette, Gilles, Hah, Zaegyoo , Lynch, Ted , Macdonald, Michael , Managuli, Ravi , Nightingale, Kathryn R. , Obuchowski, Nancy A. , Rouze, Ned C. , Morris, D. Cody , Fielding, Shana, Chan, Derek Y. , Choudhury, Kingshuk Roy , Yang, Siyun , Shamdasani, Vijay, Wear, Keith A. , Xie, Hua , Qiang, Bo, Rosenzweig, Stephen, Okamura, Yoko, McLaughlin, Glen, Chen, Yuling , Napolitano, David , Carlson, Lindsey , Erpelding, Todd N. , Barr, Richard , Carson, Paul , Dhyani, Manish , Ehman, Richard , Hah, Zaegyoo , Lynch, Ted , Macdonald, Michael , Managuli, Ravi , Miette, Veronique , Nightingale, Kathryn R , Obuchowski, Nancy , Rouze, Ned C , Morris, D Cody , Deng, Yufeng , Chan, Derek , Choudhury, Kingshuk , Samir, Anthony E , Urban, Matthew W , Wear, Keith , Ozturk, Arinc , Song, Pengfei , McAleavey, Stephen , Napolitano, David , Carlson, Lindsey , Hall, Timothy J , Chen, Jun , Miette, Véronique , Urban, Matthew W. , Song, Pengfei , Wang, Michael , Hall, Timothy J.

Journal of Ultrasound in Medicine | January 10, 2021 | Volume: 40 | Issue: 3 | Pages: 569-581

10.1002/jum.15609 Get It

ObjectivesTo quantify the bias of shear wave speed (SWS) measurements between different commercial ultrasonic shear elasticity systems and a magnetic resonance elastography (MRE) system in elastic and viscoelastic phantoms.MethodsTwo elastic phantoms, representing healthy through fibrotic liver, were measured with 5 different ultrasound platforms, and 3 viscoelastic phantoms, representing healthy through fibrotic liver tissue, were measured with 12 different ultrasound platforms. Measurements were performed with different systems at different sites, at 3 focal depths, and with different appraisers. The SWS bias across the systems was quantified as a function of the system, site, focal depth, and appraiser. A single MRE research system was also used to characterize these phantoms using discrete frequencies from 60 to 500 Hz.ResultsThe SWS from different systems had mean difference 95% confidence intervals of ±0.145 m/s (±9.6%) across both elastic phantoms and ± 0.340 m/s (±15.3%) across the viscoelastic phantoms. The focal depth and appraiser were less significant sources of SWS variability than the system and site. Magnetic resonance elastography best matched the ultrasonic SWS in the viscoelastic phantoms using a 140 Hz source but had a − 0.27 ± 0.027‐m/s (−12.2% ± 1.2%) bias when using the clinically implemented 60‐Hz vibration source.ConclusionsShear wave speed reconstruction across different manufacturer systems is more consistent in elastic than viscoelastic phantoms, with a mean difference bias of < ±10% in all cases. Magnetic resonance elastographic measurements in the elastic and viscoelastic phantoms best match the ultrasound systems with a 140‐Hz excitation but have a significant negative bias operating at 60 Hz. This study establishes a foundation for meaningful comparison of SWS measurements made with different platforms.
Repeatability of linear and nonlinear quantitative compression elastography in the breast
Barbone, Paul E. , Gendin, Daniel , Wang, Yuqi , Nayak, Rohit , Oberai, Assad A. , Hall, Timothy J. , Alizad, Azra , Fatemi, Mostafa

The Journal of the Acoustical Society of America | April 24, 2019 | Volume: 145 | Issue: 3_Supplement | Pages: 1891-1891

10.1121/1.5101854 Get It

Compression elastography allows the precise measurement of large deformations of soft tissue in vivo. From a measured large deformation, an inverse problem for both the linear and nonlinear elastic moduli distributions can be solved. As part of a larger clinical study to evaluate NEMs in breast cancer, we evaluate the repeatability of linear and nonlinear modulus maps from repeat measurements. Within the cohort of 31 subjects scanned to date, several had repeated scans. These repeated scans were processed to evaluate NEM repeatability. In vivo data were acquired by a custom, digitally controlled, uniaxial compression device with force feedback. RF-data were acquired using plane wave imaging, at a frame-rate of 200 Hz, with a ramp-and-hold compressive force of 8N, applied at 8 N/s. A two-dimensional (2D) block-matching algorithm was used to obtain sample-level displacement fields which were then tracked at subsample resolution using 2D cross correlation. Linear and nonlinear elasticity parameters in the Blatz model of tissue elasticity are estimated using iterative optimization. Repeatability between both modes and elastic modulus maps is measured and compared. Preliminary results indicate that when images are acquired in the same region of tissue, the modulus maps are consistent. [Work supported by NIH R01CA195527.]