2025 47th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) | December 3, 2025 | Volume: No volume available | Issue: No issue available | Pages: 1-5
Comparison of Quantitative High-definition Microvessel Imaging and Shear Wave Elastography in Preoperative Prediction of Axillary Lymph Node Breast Cancer Metastasis
Abstract Background Accurate assessment of axillary lymph nodes (ALNs) is a critical step for timely diagnosis of metastasis and proper subsequent intervention in breast cancer patients. Herein, we compare the diagnostic utility of quantitative high-definition microvasculature imaging (qHDMI), shear wave elastography (SWE) and their combination for differentiation of metastatic ALNs from reactive. Methods A total of 85 female patients with suspicious ALNs recommended for fine needle aspiration biopsy (FNAB) were included in the study, and the pathology results were used as the gold standard for labeling the status of each ALN. Three SWE metrics and ten qHDMI-derived biomarkers were used in our analyses. Additionally, age, as well as clinical ultrasound features such as nodal size and cortical thickness were included as clinical factors. The Wilcoxon rank-sum test was utilized to analyze distributional differences in biomarkers between metastatic and reactive ALNs. Multiple elastic-net logistic regression models were developed based on varying combinations of clinical, qHDMI, and SWE feature sets. A 70%/30% train/test split was adopted, and ROC curve analyses were performed to evaluate and compare classification performance. Moreover, distributional differences in qHDMI and SWE biomarkers between ALNs corresponding to breast cancer immunohistochemical subtypes luminal A and B were investigated. Results Of the total of 85 ALNs included in the analysis, 42 were metastatic. Statistically significant (p-value < 0.05) differences were observed in all but one of the qHDMI biomarkers, as well as all the SWE metrics. Test-set discrimination defined by area under ROC curve (AUC) was low for the model using only clinical features (0.62; 95% CI = [0.39,0.84]), with higher performance observed for models using SWE only (0.93; [0.82,1.00]), qHDMI only (0.97; [0.91,1.00]), qHDMI-SWE (0.97; [0.92,1.00]), and qHDMI-SWE plus clinical biomarkers (0.98; [0.94,1.00]). No statistically significant improvements were seen in the combined SWE-qHDMI and SWE-qHDMI-C classification models relative to the qHDMI-only model, although power for comparison was limited. Four qHDMI biomarkers and two SWE measures exhibited statistically significant distributions among breast cancer luminal A and B subtypes. Conclusions qHDMI classification model was able to separate metastatic from reactive ALNs with high accuracy. qHDMI, SWE, and the combined models had improved classification performance over the baseline Clinical model. qHDMI biomarkers can be valuable in determining the malignancy status of suspicious ALNs, providing helpful information regarding breast cancer prognosis.
A Force-Matched Approach to Large-Strain Nonlinearity in Elasticity Imaging for Breast Lesion Characterization
Abstract Objective . Detrusor overactivity (DO) is a urodynamic observation characterized by fluctuations in detrusor pressure ( P det ) of the bladder. Although detecting DO is important for the management of bladder symptoms, the invasive nature of urodynamic studies (UDS) makes it a source of discomfort and morbidity for patients. Ultrasound bladder vibrometry (UBV) could provide a direct and noninvasive means of detecting DO, due to its sensitivity to changes in elasticity and load in the bladder wall. In this study, we investigated the feasibility and applying UBV toward detecting DO. Approach . UBV and urodynamic study (UDS) measurements were collected in 76 neurogenic bladder patients (23 with DO). Timestamped group velocity squared ( c g 2 ) data series were collected from UBV measurements. Concurrent P det data series were identically analyzed for comparison and validation. A processing approach is developed to separate transient fluctuations in the data series from the larger trend of the data and a DO index is proposed for characterizing the transient peaks observed in the data. Main Results. Applying the DO index as a classifier for DO produced sensitivities and specificities of 0.70 and 0.75 for c g 2 data series and 0.70 and 0.83 for P det data series respectively. Significance . It was found that DO can be feasibly detected from data series of timestamped UBV measurements. Collectively, these initial results are promising, and further refinement to the UBV measurement process is likely to improve and clarify its capabilities for noninvasive detection of DO.