Objectives We analyzed growth rates of benign ovarian serous cystadenomas and cystadenofibromas to understand what percentage would show a volume doubling time (DT) of less than 3 years, between 3 and 5 years, or greater than 5 years. Methods We retrospectively reviewed pathology records (January 1, 2014, to June 30, 2019) to find all surgically excised ovarian serous cystadenomas and cystadenofibromas. Imaging records were then reviewed to identify those that had been confidently identified with ultrasound imaging, magnetic resonance imaging, or computed tomography at least twice before surgical removal, with at least a 60‐day interval between studies. Three orthogonal measurements were recorded on the first and last imaging studies on which the mass was detected, with volume calculations by the prolate formula (product of 3 measurements multiplied by 0.52). The volume DT was calculated and grouped into 1 of 5 categories: (1) DT of less than 1 year; (2) DT of 1 to 3 years; (3) DT of 3 to 5 years; (4) DT of 5 to 10 years; and (5) no growth (any mass with a DT >10 years or showing a decrease in volume). Results A total of 102 of 536 cystadenomas and 44 of 227 cystadenofibromas met inclusion criteria. Of the 146 tumors, 40 (27.4%) had a DT of less than 1 year; 38 (26.0%) had a DT of 1 to 3 years; 22 (15.1%) had a DT of 3 to 5 years; 10 (6.8%) had a DT of 5 to 10 years; and 36 (24.7%) showed no growth. Conclusions A total of 53.4% of ovarian serous cystadenomas/cystadenofibromas have a DT of less than 3 years; 15.1% have a DT between 3 and 5 years; and 31.5% have a DT of greater than 5 years or show no growth.
Added Benefit and Risk of an Additional Biopsy or Targeting With Contrast‐Enhanced Ultrasound for Patients With Renal Transplants
ObjectivesTo determine whether renal transplant diagnoses substantially change when 2 biopsy sites are chosen and whether contrast‐enhanced ultrasound (CEUS) has value for targeting the second site.MethodsWe prospectively enrolled 40 patients undergoing ultrasound‐guided renal transplant biopsy within 2 years of transplant: 20, surveillance; and 20, for cause. A CEUS examination was performed to identify cortical regions with subjectively altered flow. One biopsy was performed at the operator‐preferred (primary) site regardless of CEUS findings. Another biopsy was done at a second location, either targeted to an area in which CEUS perfusion findings differed from the primary site (targeted) or at a random location (secondary) if no other area differed. Specimens were randomly labeled A or B; pathologists were blinded to the CEUS result and biopsy location. Location‐specific CEUS assessments were recorded. Pathologic results were compared, including acute and chronic Banff scores and any new findings from the targeted or secondary biopsy.ResultsForty patients were enrolled between January 2016 and December 2018. No location‐specific pathologic differences correlated with differences in CEUS assessments. The second biopsy provided additional information that changed management in 4 of 40 patients (10.0% [95% confidence interval, 2.8%–23.7%]). Major bleeding complications occurred in 3 of 40 (7.5%) patients.ConclusionsContrast‐enhanced ultrasound targeting was not useful. Major bleeding complications were higher than expected, possibly due to the additional biopsy away from the operator‐preferred location. Obtaining a second renal transplant biopsy from a substantially different area than the initial operator‐preferred location provided additional clinically useful information in 10% of patients.
Impact of Uterine Sliding Sign in Routine United States Ultrasound Practice
ObjectivesThe study aim was to evaluate the diagnostic performance of the uterine sliding sign in predicting deeply infiltrating endometriosis in the setting of non‐physician sonographers performing but not interpreting the maneuver. The impact of uterine sliding sign has not been previously demonstrated in this practice setting.MethodsPhysicians' remote interpretations of transvaginal ultrasound examinations in 2016, before uterine sliding sign, were compared to examinations in 2019 after addition of uterine sliding sign to determine the diagnostic rates. Surgical and histopathological results were reviewed to determine sensitivity and specificity of the respective exam techniques.ResultsTwo hundred eighty‐five transvaginal ultrasounds were performed in 2016 and 390 sliding sign ultrasounds in 2019. The number of deeply infiltrating endometriosis cases identified increased significantly from 2% to 6% during the study period (chi‐square, Fisher's exact test p = .012). The sensitivity and specificity of routine pelvic sonography for detecting deeply infiltrating endometriosis improved from 36%/94% to 68%/98%.ConclusionsUterine sliding sign videos should be included in the standard sonographic protocol for patients presenting with chronic pelvic pain, endometriosis history, or sonographic evidence of endometriosis in the setting of physicians interpreting sonographic images obtained by non‐physicians.
Radiologists Make More Errors Interpreting Off-Hours Body CT Studies during Overnight Assignments as Compared with Daytime Assignments
Abnormal Preprocedural International Normalized Ratio and Platelet Counts Are Not Associated With Increased Bleeding Complications After Ultrasound-Guided Thoracentesis