How to Safely Perform Magnetic Resonance Imaging-guided Radioactive Seed Localizations in the Breast
Lee, Christine U. , Bhatt, Asha A. , Felmlee, Joel P. , Trester, Pamela S. , Lanners, Diana M, Paulsen, Andrew, Brunette, Jeffrey J., Bhatt, Asha, Trester, Pamela, Lanners, Diana, Brunette, Jeffrey

Journal of Clinical Imaging Science | April 9, 2020 | Volume: 10 | Issue: No issue available | Pages: 19

10.25259/jcis_11_2020 Get It

When a breast lesion is seen on only magnetic resonance imaging (MRI) and needs to be excised, pre-operative MRI-guided radioactive seed localization (RSL) is preferred. However, MRI safety and radiation safety issues associated with the inability to recover a potentially lost seed in the MRI scanner room (Zone IV) have precluded this in the past. This manuscript provides a protocol for MRI-guided RSLs that meets MRI safety and radiation safety criteria established by the American College of Radiology and the Nuclear Regulatory Commission. To the authors’ best knowledge, this has never been published in the literature. The complete protocol is provided.