Back to Authors

Eidem, Benjamin W.

Mayo Clinic

Mayo Clinic

Citations 21

Lambl's excrescences in children: Improved detection via transthoracic echocardiography
Phillips, Amanda L., Qureshi, M. Yasir , Eidem, Benjamin W., Cetta, Frank , Qureshi, Muhammad Y

Congenital Heart Disease | November 28, 2017 | Volume: 13 | Issue: 2 | Pages: 251-253

10.1111/chd.12560 Get It

Educational intervention for improving the appropriateness of transthoracic echocardiograms ordered by pediatric cardiologists
Sachdeva, Ritu , Douglas, Pamela S. , McCracken, Courtney , Lopez, Leo , Stern, Kenan W.D. , Eidem, Benjamin W., Benavidez, Oscar J., Weiner, Rory B., Welch, Elizabeth , Campbell, Robert M. , Kelleman, Michael Scott , Lai, Wyman W. , Douglas, Pamela S

Congenital Heart Disease | February 22, 2017 | Volume: 12 | Issue: 3 | Pages: 373-381

10.1111/chd.12455 Get It

Application of pediatric appropriate use criteria for initial outpatient evaluation of syncope
Phelps, Heather M. , McCracken, Courtney , Benavidez, Oscar J., Campbell, Robert M. , Douglas, Pamela S. , Eidem, Benjamin W., Lopez, Leo , Stern, Kenan W.D. , Welch, Elizabeth , Sachdeva, Ritu , Kelleman, Michael Scott , Lai, Wyman W. , Douglas, Pamela S

Echocardiography | February 8, 2017 | Volume: 34 | Issue: 3 | Pages: 441-445

10.1111/echo.13475 Get It

BackgroundSyncope is a common reason for outpatient transthoracic echocardiography (TTE). We studied the applicability of pediatric appropriate use criteria (AUC) on initial outpatient evaluation of children (≤18 years) with syncope.MethodsData were obtained before (Phase I, April–September 2014) and after (Phase II, January‐April 2015) the release of the AUC document from six participating pediatric cardiology centers. Site investigators determined the indication for TTE and assigned appropriateness rating based on the AUC document: Appropriate (A), May Be Appropriate (M), Rarely Appropriate (R), or “unclassifiable” (U) if it did not fit any scenario in the AUC document.ResultsOf the total 4562 TTEs, 310 (6.8%) were performed for syncope: 174/2655 (6.6%) Phase I and 136/1907 (7.1%) Phase II, P=.44. Overall, 168 (50.5%) were for indications rated A, 63 (18.9%) for M, 79 (23.7%) for R, and 23 (6.9%) for U. Release of AUC did not change the appropriateness of TTEs [A=51.6% vs 49.0%, P=.63, R=20.2% vs 28.3%, P=.09]. Overall syncope‐related R indications formed 15.7% of R indications for all the echocardiograms performed in the entire Pediatric Appropriate Use (PAUSE) study (11.9% Phase I and 22.4% Phase II, P=.002). TTEs were normal in majority of the patients except 7 that had incidental findings.ConclusionsIn conclusion, syncope is a common reason for indications rated R and release of the AUC document did not improve appropriate utilization of TTE in syncope. Targeted educational interventions are needed to reduce unnecessary TTEs in children with syncope.
Ventricular‐Arterial Function and Coupling in the Adult Fontan Circulation
Saiki, Hirofumi , Eidem, Benjamin W., Ohtani, Tomohito , Grogan, Martha , Redfield, Margaret M. , Grogan, Martha A

Journal of the American Heart Association | September 23, 2016 | Volume: 5 | Issue: 9 | Pages: No page available

10.1161/jaha.116.003887 Get It

Background In adult Fontan patients, ventricular or arterial dysfunction may impact homeostasis of the Fontan circulation and predispose to heart failure. We sought to characterize ventricular‐arterial ( VA ) properties in adult Fontan patients. Methods and Results Adult Fontan patients (n=170), including those with right ( SRV , n=57) and left ( SLV , n=113) dominant ventricular morphology, were compared to age, sex, and body size matched controls (n=170). Arterial function, load‐insensitive measures of contractility, VA coupling, diastolic function, and ventricular efficiency were assessed. Compared to controls, Fontan patients had similar arterial (Ea), but lower end‐systolic ventricular (Ees), elastance, preload recruitable stroke work and peak power index, impaired VA coupling, eccentric remodeling, reduced ventricular efficiency and increased diastolic stiffness ( P <0.05 for all). Ventricular efficiency declined steeply with higher heart rate in Fontan, but not control, patients. Among Fontan patients (n=123) and controls (n=162) with preserved cardiac index ( CI ; ≥2.5 L/min per m 2 ), Fontan patients had worse contractility than controls, but CI was preserved owing to relative tachycardia, lower afterload, and eccentric remodeling. However, 25% of Fontan patients had reduced CI and were distinguished from those with preserved CI by less‐eccentric remodeling and worse diastolic function, rather than more‐impaired contractility. Conclusions Adult Fontan patients have contractile and diastolic dysfunction with normal afterload, impaired VA coupling, and reduced ventricular efficiency with heightened sensitivity to heart rate. Maintenance of CI is dependent on lower afterload, eccentric remodeling, and relative preservation of diastolic function. These data contribute to our understanding of circulatory physiology in adult Fontan patients.
Improved Ventricular Function after TEE-guided Cardioversion of Atrial Arrhythmias in Patients after the Fontan Operation
Poterucha, Joseph T., Egbe, Alexander C. , Johnson, Jonathan N. , Wackel, Phillip L., Cannon, Bryan C. , Eidem, Benjamin W., Cetta, Frank , Niaz, Talha

Congenital Heart Disease | March 31, 2016 | Volume: 11 | Issue: 6 | Pages: 578-583

10.1111/chd.12339 Get It

Cardiorespiratory Response to Exercise before and after Pulmonary Valve Replacement in Patients with Repaired Tetralogy of Fallot: A Retrospective Study and Systematic Review of the Literature
Sabaté-Rotés, Anna , Johnson, Jonathan N. , Burkhart, Harold M. , Eidem, Benjamin W., Allison, Thomas G. , Driscoll, David J.

Congenital Heart Disease | August 4, 2014 | Volume: 10 | Issue: 3 | Pages: 263-270

10.1111/chd.12207 Get It

Two‐Dimensional Measurement of Tricuspid Annular Plane Systolic Excursion in Children: Can It Substitute for an M‐Mode Assessment?
Qureshi, M. Yasir , Eidem, Benjamin W., Reece, Chelsea L., Qureshi, Muhammad Yasir, O’Leary, Patrick , Qureshi, Muhammad Y

Echocardiography | July 22, 2014 | Volume: 32 | Issue: 3 | Pages: 528-534

10.1111/echo.12687 Get It

BackgroundTricuspid annular plane systolic excursion measured by M‐mode (MM‐TAPSE) has been validated as a marker of right ventricular systolic performance. A similar measurement by 2D imaging (2D‐TAPSE) can be obtained. We sought to determine the correlation and strength of agreement between MM‐TAPSE and 2D‐TAPSE in children.MethodsEchocardiographic studies performed for clinical indications were reviewed retrospectively. All consecutive subjects ≤18 years of age were included. The cohort was divided into those with normal echocardiographic findings and those with disorders affecting the right ventricle. Digitally recorded images were analyzed for both MM‐TAPSE and 2D‐TAPSE. Measurements of 2D‐TAPSE were made in an apical four‐chamber view, from the tricuspid valve annulus to a consistent point at the apex of the imaging sector at end‐diastole and end‐systole, with the difference representing the 2D‐TAPSE value.ResultsA total of 329 subjects (mean age 9.0 ± 6.1 years) met entry criteria. Correlation coefficient between MM‐TAPSE and 2D‐TAPSE was 0.90. Bland–Altman analysis showed agreement between the two methods to be within 1.2 ± 2.6 mm (mean percentage difference of 6.5%). About 1 mm difference between MM‐TAPSE and 2D‐TAPSE was consistently observed in all diagnostic subgroups, and across all age categories.ConclusionMM‐TAPSE and 2D‐TAPSE correlate strongly, with 2D‐TAPSE being consistently about 1 mm less than values obtained by the M‐mode technique. We conclude that 2D‐TAPSE can provide a reliable alternative to MM‐TAPSE to quantitatively measure right ventricular systolic function and may be especially useful in situations where retrospective comparisons are sought.
Cone Reconstruction in Children with Ebstein Anomaly: The Mayo Clinic Experience
Anderson, Heather N., Dearani, Joseph A. , Said, Sameh M. , Norris, Mark D. , Pundi, Kavitha N., Miller, Angela R., Cetta, Michael L., Eidem, Benjamin W., Cetta, Frank , Dearani, Joseph A. , O’Leary, Patrick

Congenital Heart Disease | December 23, 2013 | Volume: 9 | Issue: 3 | Pages: 266-271

10.1111/chd.12155 Get It

Impaired Left Ventricular Mechanics in Pulmonary Arterial Hypertension
Hardegree, Evan L., Sachdev, Arun, Fenstad, Eric R. , Villarraga, Hector R. , Frantz, Robert P. , McGoon, Michael D., Oh, Jae K. , Ammash, Naser M., Connolly, Heidi M. , Eidem, Benjamin W., Pellikka, Patricia A. , Kane, Garvan C. , Pellikka, Patricia A , Frantz, Robert P

Circulation: Heart Failure | May 25, 2013 | Volume: 6 | Issue: 4 | Pages: 748-755

10.1161/circheartfailure.112.000098 Get It

Background— Pulmonary arterial hypertension (PAH) is characterized by pulmonary vascular remodeling and right heart failure. The right (RV) and left ventricles (LV) do not function in isolation, sharing a common pericardial sac and interventricular septum. We sought to define the clinical and prognostic significance of ventricular interdependence in PAH and its association with LV filling patterns through speckle-tracking strain echocardiography. Methods and Results— Echocardiography was performed in 71 adults with a new diagnosis of PAH. To analyze LV and RV function separately, we measured peak systolic longitudinal and circumferential strain of the LV and RV. Survival was assessed >2 years. Patients had dilated right-sided chambers (right atrial volume index, 44±19 mL/m 2 ; RV end-diastolic area, 34±9 cm 2 ), and reduced RV function (RV fractional area change, 28±12%). Speckle-tracking echocardiography revealed significant reductions in RV free wall peak systolic strain (−15±3%). Despite normal LV size and normal conventional measures of LV systolic function (end-diastolic dimension, 42±6 mm; ejection fraction, 65±8%; cardiac index, 2.6±0.8 L/min per m 2 ), patients had reduced LV free wall systolic strain (−15±3%). Decreased LV free wall systolic strain was associated with a delayed relaxation mitral inflow Doppler pattern, P =0.0002. During 2-year follow-up, 19 patients (27%) died. LV strain was associated with increased mortality (unadjusted hazard ratio, 2.40 per 5% decrease in LV free wall strain, 1.22–4.68), which remained significant when adjusted for age, sex, World Health Organization functional class, and PAH pathogenesis (hazard ratio, 3.11, 1.38–7.20). Conclusions— The pressure loading in PAH results in geometric alterations and functional decline of the RV, with marked reduction in RV systolic strain. Despite preservation of LV ejection fraction, LV systolic strain was also reduced and associated with early mortality, highlighting the significance of ventricular interdependence in PAH.
Effect of percutaneous atrial septal defect and patent foramen ovale device closure on degree of aortic regurgitation
Loar, Robert W. , Johnson, Jonathan N. , Cetta, Frank , Hagler, Donald J. , Eidem, Benjamin W., Taggart, Nathaniel W. , Cabalka, Allison K. , Taggart, Nathaniel W

Catheterization and Cardiovascular Interventions | December 14, 2012 | Volume: 81 | Issue: 7 | Pages: 1234-1237

10.1002/ccd.24779 Get It

BackgroundIn recent years, percutaneous device closure has become commonplace for treatment of atrial septal defect (ASD) and patent foramen ovale (PFO). However, the effect of device closure on aortic valve regurgitation (AR) has been questioned.ObjectiveThe purpose of this study was to define changes in AR using echocardiography, before and after device closure of ASD or PFO.MethodsWe retrospectively reviewed all patients who had percutaneous device closure of ASD or PFO at our institution between 2005 and 2009. We compared the preprocedure echocardiogram to the most recent follow‐up study. All investigators were blinded to referral diagnosis, patient demographics, and size and type of the device placed. Aortic regurgitation was graded as none/trivial, mild, moderate, or severe.ResultsOverall, 322 patients qualified for inclusion; 204 with PFO and 118 with ASD. Mean age at time of closure was 48 ± 20 years (range 3–85 years). Mean duration of follow‐up was 1.2 years (range 2 months to 5 years). Only two patients (0.6%) demonstrated any appreciable increase in AR severity. However, both of these patients manifested a clinically insignificant change from a trivial to mild grade of aortic regurgitation.ConclusionsPercutaneous device closure of PFO or ASD does not increase the incidence or severity of AR over medium‐term follow‐up. © 2012 Wiley Periodicals, Inc.