Abstract BACKGROUND Brain mapping is the most reliable intraoperative tool for identifying surrounding functional cortical and subcortical brain parenchyma. Brain mapping procedures are nuanced and require a multidisciplinary team and a well-trained neurosurgeon. Current training methodology involves real-time observation and operation, without widely available surgical simulation. OBJECTIVE To develop a patient-specific, anatomically accurate, and electrically responsive biomimetic 3D-printed model for simulating brain mapping. METHODS Imaging data were converted into a 2-piece inverse 3D-rendered polyvinyl acetate shell forming an anatomically accurate brain mold. Functional and diffusion tensor imaging data were used to guide wire placement to approximate the projection fibers from the arm and leg areas in the motor homunculus. Electrical parameters were generated, and data were collected and processed to differentiate between the 2 tracts. For validation, the relationship between the electrical signal and the distance between the probe and the tract was quantified. Neurosurgeons and trainees were interviewed to assess the validity of the model. RESULTS Material testing of the brain component showed an elasticity modulus of 55 kPa (compared to 140 kPa of cadaveric brain), closely resembling the tactile feedback a live brain. The simulator's electrical properties approximated that of a live brain with a voltage-to-distance correlation coefficient of r 2 = 0.86. Following 32 neurosurgeon interviews, ∼96% considered the model to be useful for training. CONCLUSION The realistic neural properties of the simulator greatly improve representation of a live surgical environment. This proof-of-concept model can be further developed to contain more complicated tractography, blood and cerebrospinal fluid circulation, and more in-depth feedback mechanisms.
Operative Adjuncts and Technique for En Bloc Removal of Lumbar Intradural-Extramedullary Tumor: 2-Dimensional Operative Video
Abstract We present a surgical video illustrating the technique for en bloc resection of an intradural-extramedullary lumbar tumor. The patient is a 63-yr-old woman presenting with worsening bilateral leg pain. Imaging of her lumbar spine showed an enhancing, circumscribed intradural-extramedullary tumor compressing her cauda equina at the L2 level. With informed patient consent, an L1-L3 laminectomy was performed, and intraoperative ultrasound provided the tumor location in order to plan the dural opening as well as define the tumor boundaries with respect to the surrounding nerve roots. The nerve roots were found to be dorsal to the tumor on the ultrasound and appeared to be separate from the tumor capsule. After the dura was opened, the nerve roots were dissected from the tumor capsule and the filum was identified at its proximal and distal portions relative to the mass. The tumor appeared to be arising from the filum itself. Intraoperative electromyography monitoring and stimulation identified the motor roots around the filum and were dissected away. The filum was isolated and cut proximally in order to prevent upward displacement of the mass above the dural opening. The distal portion was then cut and the tumor was removed en bloc. The patient had good postoperative relief of her leg pain and no new neurologic or genitourinary complications. This case highlights the preoperative and intraoperative surgical planning as well as detailed technical aspects of en bloc intradural-extramedullary lumbar tumor resection with preservation of the tumor capsule in order to achieve gross total resection.
Letter: The Living Spine Model: A Biomimetic Surgical Training and Education Tool
AbstractIntroductionThree‐dimensional (3D) printing of anatomical structures is a growing method of education for students and medical trainees. These models are generally produced as static representations of gross surface anatomy. In order to create a model that provides educators with a tool for demonstration of kinematic and physiologic concepts in addition to surface anatomy, a high‐resolution segmentation and 3D‐printingtechnique was investigated for the creation of a dynamic educational model.MethodsAn anonymized computed tomography scan of the cervical spine with a diagnosis of ossification of the posterior longitudinal ligament was acquired. Using a high‐resolution thresholding technique, the individual facet and intervertebral spaces were separated, and models of the C3–7 vertebrae were 3D‐printed. The models were placed on a myelography simulator and subjected to flexion and extension under fluoroscopy, and measurements of the spinal canal diameter were recorded and compared to in‐vivo measurements. The flexible 3D‐printed model was then compared to a static 3D‐printed model to determine the educational benefit of demonstrating physiologic concepts.ResultsThe canal diameter changes on the flexible 3D‐printed model accurately reflected in‐vivo measurements during dynamic positioning. The flexible model also was also more successful in teaching the physiologic concepts of spinal canal changes during flexion and extension than the static 3D‐printed model to a cohort of learners.ConclusionsDynamic 3D‐printed models can provide educators with a cost‐effective and novel educational tool for not just instruction of surface anatomy, but also physiologic concepts through 3D ex‐vivo modeling of case‐specific physiologic and pathologic conditions.
Microanatomical considerations for safe uncinate removal during anterior cervical discectomy and fusion: 10‐year experience
AbstractCervical radiculopathy from uncovertebral joint (UVJ) hypertrophy and nerve root compression often occurs anterior and lateral within the cervical intervertebral foramen, presenting a challenge for complete decompression through anterior cervical approaches owing to the intimate association with the vertebral artery and associated venous plexus. Complete uncinatectomy during anterior cervical discectomy and fusion (ACDF) is a controversial topic, many surgeons relying on indirect nerve root decompression from restoration of disc space height. However, in cases of severe UVJ hypertrophy, indirect decompression does not adequately address the underlying pathophysiology of anterolateral foraminal stenosis. Previous reports in the literature have described techniques involving extensive dissection of the cervical transverse process and lateral uncinate process (UP) in order to identify the vertebral artery for safe removal of the UP. Recent anatomical investigations have detailed the microanatomical organization of the fibroligamentous complex surrounding the UP and neurovascular structures. The use of the natural planes formed from the encapsulation of these connective tissue layers provides a safe passage for lateral UP dissection during anterior cervical approaches. This can be performed from within the disc space during ACDF to avoid extensive lateral dissection. In this article, we present our 10‐year experience using an anatomy‐based microsurgical technique for safe and complete removal of the UP during ACDF for cervical radiculopathy caused by UVJ hypertrophy.
Ex vivo virtual and 3D printing methods for evaluating an anatomy‐based spinal instrumentation technique for the 12th thoracic vertebra
AbstractIntroductionThree‐dimensional printing and virtual simulation both provide useful methods of patient‐specific anatomical modeling for assessing and validating surgical techniques. A combination of these two methods for evaluating the feasibility of spinal instrumentation techniques based on anatomical landmarks has not previously been investigated.Materials and MethodsNineteen anonymized CT scans of the thoracic spine in adult patients were acquired. Maximum pedicle width and height were recorded, and statistical analysis demonstrated normal distributions. The images were converted into standard tessellation language (STL) files, and the T12 vertebrae were anatomically segmented. The intersection of two diagonal lines drawn from the lateral and medial borders of the T12 transverse process (TP) to the lateral border of the pars and inferolateral portion of the TP was identified on both sides of each segmented vertebra. A virtual screw was created and insertion into the pedicle on each side was simulated using the proposed landmarks. The vertebral STL files were then 3D‐printed, and 38 pedicles were instrumented according to the individual posterior landmarks used in the virtual investigation.ResultsThere were no pedicle breaches using the proposed anatomical landmarks for insertion of T12 pedicle screws in the virtual simulation component. The technique was further validated by additive manufacturing of individual T12 vertebrae and demonstrated no breaches or model failures during live instrumentation using the proposed landmarks.ConclusionsEx vivo modeling through virtual simulation and 3D printing provides a powerful and cost‐effective means of replicating vital anatomical structures for investigation of complex surgical techniques.
The three‐dimensional printing renaissance of individualized anatomical modeling: Are we repeating history?
AbstractThree‐dimensional (3D) printing has revolutionized individualized medicine for patient‐specific anatomical modeling and surgical planning. The surge of investigations in model creation for preoperative assessments and patient education has demonstrated improvements in both operative factors and patient satisfaction. In addition, recent technologic advances in 3D printing techniques have provided a resource to create visually pleasing models with chromatic cues for segmentation of adjacent structures. Despite these advances, an important consideration that has yet to be addressed is the quality of representation of the not only the form of structures created, but also the functional relationships of each structure. Jean François Fernel (1497–1558 AD) recognized a similar trend in anatomic innovation over 500 years ago, and sparked a series of texts that challenged the superficial anthropocentric views of the time and led to the foundation of physiologic principles that shaped modern medical philosophy. Accurately generating anatomical structures are directly related to discerning true physiologic function, and a comprehensive understanding of both is essential to hold accountability in fidelity for individualized 3D printing.
Clinical implications of nervus intermedius variants in patients with geniculate neuralgia: Let anatomy be the guide
AbstractGeniculate neuralgia (GN) is an uncommon, but severe, condition that is characterized by excruciating paroxysmal pain in the seventh cranial nerve's cutaneous distribution of general somatic afferent fibers carried through the nervus intermedius (NI). GN becomes a surgical disease in refractory cases of pain after exhaustive medical management. Surgical intervention in the form of microvascular decompression and nerve sectioning has been investigated with good patient outcomes. Despite this, there are limited guidelines on either technique's appropriateness in specific operative scenarios. In our 30‐year experience in GNs surgical management, we have found that a detailed knowledge of the NIs anatomy, variants, and intraoperative surgical anatomic findings are the key to choosing the most appropriate intervention, and may provide the answer to why some patients fail to experience pain relief after surgery. These anatomic variants also may explain why many patients commonly do not experience side effects related to the visceral efferent and special afferent fibers after nerve sectioning.
3-Dimensionally Printed Biomimetic Surgical Simulation—Operative Technique of a Transforaminal Lumbar Interbody Fusion: 2-Dimensional Operative Video
Abstract We present a surgical video highlighting the technical demonstration and microsurgical anatomy of an L4-5 transforaminal lumbar interbody fusion utilizing a combination of thermoplastic polymers and 3-dimensional printing technology to create a biomimetic lumbar spine surgical simulator. The posterior elements of L4-5 and the inferior portion of L3 are exposed in their entirety, including the transverse processes in order to identify the appropriate landmarks for pedicle screw insertion. The interspinous ligament of L4-5 is removed, and an interlaminar spreader is used to distract the facet joint. An inferior L4 facetectomy is performed for local autograft harvesting. The L4 and L5 pedicles are skeletonized to completely open the foramen in order to ensure that the exiting nerve root will not be compromised during cage insertion. The ligamentum flavum is then removed, exposing the common thecal sac and L5 traversing root. The L4 exiting nerve root is then identified, completing Kambin's triangle and location of the disc space. The disc is incised, and a combination of punches and curettes are used to completely remove the disc. After an interbody trial is used to assess the proper cage size, the cage is packed with graft and inserted into the midline of the disc space. Pedicle screws are then placed using an anatomic freehand technique, and intraoperative fluoroscopy is performed in order to evaluate the instrumentation and interbody position. If a contralateral decompression is required, a facet-sparing technique is performed in order to preserve bony surface for the fusion. Patient consent was not required for this simulation video.
The importance of teaching clinical anatomy in surgical skills education: Spare the patient, use a sim!