Back to Authors

Larson, A Noelle

0000-0001-6542-6975

Mayo Clinic

Mayo Clinic

Citations 34

Ultrasound Radiation Force for the Assessment of Bone Fracture Healing in Children: An In Vivo Pilot Study
Ghavami, Siavash , Gregory, Adriana , Webb, Jeremy, Bayat, Mahdi , Denis, Max , Milbrand, Todd A., Larson, A. Noelle , Fatemi, Mostafa , Alizad, Azra , Kumar, Viksit, Larson, A Noelle , Alizad, Azra , Fatemi, Mostafa , Kumar, Viksit

Sensors | February 25, 2019 | Volume: 19 | Issue: 4 | Pages: 955

10.3390/s19040955 Get It

Vibrational characteristics of bone are directly dependent on its physical properties. In this study, a vibrational method for bone evaluation is introduced. We propose a new type of quantitative vibro-acoustic method based on the acoustic radiation force of ultrasound for bone characterization in persons with fracture. Using this method, we excited the clavicle or ulna by an ultrasound radiation force pulse which induces vibrations in the bone, resulting in an acoustic wave that is measured by a hydrophone placed on the skin. The acoustic signals were used for wave velocity estimation based on a cross-correlation technique. To further separate different vibration characteristics, we adopted a variational mode decomposition technique to decompose the received signal into an ensemble of band-limited intrinsic mode functions, allowing analysis of the acoustic signals by their constitutive components. This prospective study included 15 patients: 12 with clavicle fractures and three with ulna fractures. Contralateral intact bones were used as controls. Statistical analysis demonstrated that fractured bones can be differentiated from intact ones with a detection probability of 80%. Additionally, we introduce a “healing factor” to quantify the bone healing progress which successfully tracked the progress of healing in 80% of the clavicle fractures in the study.
The Utility of Routine Postoperative Radiographs After Pinning of Pediatric Supracondylar Humerus Fractures
Karalius, Vytas P. , Stanfield, Jacob, Ashley, Philip, Lewallen, Laura, deDeugd, Casey, Walker, Janet L. , Larson, A. Noelle , Milbrandt, Todd A. , Larson, A Noelle

Journal of Pediatric Orthopaedics | April 25, 2017 | Volume: 37 | Issue: 5 | Pages: e309-e312

10.1097/bpo.0000000000001000 Get It

Background: The purpose of this study was to determine the frequency with which postoperative radiographs resulted in a change in management following closed reduction and percutaneous pinning of displaced pediatric supracondylar humerus fractures. We hypothesize that only the initial postoperative radiograph will lead to changes in management of operative supracondylar humerus fractures. Methods: A retrospective review was performed at 2 level I pediatric trauma centers. Inclusion criteria were patients below 18 years of age who sustained supracondylar humerus fractures (Gartland type II, III, IV) who were operatively treated from 2008 to 2013 with adequate radiographic follow-up. Patients with flexion type, intra-articular, transphyseal, and open fractures were excluded from the study. Routine radiographs were taken at initial follow-up (1 wk postoperatively) and at pin removal (3 to 4 wk postoperatively). Results: The final analysis included 572 patients. Initial postoperative radiographs changed treatment in 9 patients (1.6%), including revision surgeries, 2 pin adjustments, and 2 early pin removals. At the time of pin removal, 20 (3.5%) patients required further immobilization. There were no changes to the initial plan for continued nonoperative treatment at final follow-up (6 to 8 wk postoperatively). Conclusions: In this large retrospective series of patients treated with closed reduction and percutaneous pinning of displaced supracondylar humerus fractures, radiographs at 3 weeks do not reveal a need to return to the operating room or other significant pathology. These findings suggest that radiographs should be obtained within 7 to 10 days postoperatively for type III fractures and may only need to be repeated if the clinical situation warrants it, such as severe fracture pattern, persistent pain, or clinical deformity. Level of Evidence: Level IV—case series.
Molecular Validation of Chondrogenic Differentiation and Hypoxia Responsiveness of Platelet-Lysate Expanded Adipose Tissue–Derived Human Mesenchymal Stromal Cells
Galeano‐Garces, Catalina , Camilleri, Emily T. , Riester, Scott M. , Dudakovic, Amel , Qu, Wenchun , Smith, Jay , Dietz, Allan B. , Im, Hee‐Jeong, Krych, Aaron J. , Larson, A. Noelle , Karperien, Marcel , Wijnen, André J. van , Camilleri, Emily , Larson, Dirk R. , van Wijnen, Andre J, Im, Hee‐Jeong , van Wijnen, Andre J , Krych, Aaron J , Larson, A Noelle , Dietz, Allan B , Camilleri, Emily

CARTILAGE | July 22, 2016 | Volume: 8 | Issue: 3 | Pages: 283-299

10.1177/1947603516659344 Get It

Objective: To determine the optimal environmental conditions for chondrogenic differentiation of human adipose tissue–derived mesenchymal stromal/stem cells (AMSCs). In this investigation we specifically investigate the role of oxygen tension and 3-dimensional (3D) culture systems. Design: Both AMSCs and primary human chondrocytes were cultured for 21 days in chondrogenic media under normoxic (21% oxygen) or hypoxic (2% oxygen) conditions using 2 distinct 3D culture methods (high-density pellets and poly-ε-caprolactone [PCL] scaffolds). Histologic analysis of chondro-pellets and the expression of chondrocyte-related genes as measured by reverse transcriptase quantitative polymerase chain reaction were used to evaluate the efficiency of differentiation. Results: AMSCs are capable of expressing established cartilage markers including COL2A1, ACAN, and DCN when grown in chondrogenic differentiation media as determined by gene expression and histologic analysis of cartilage markers. Expression of several cartilage-related genes was enhanced by low oxygen tension, including ACAN and HAPLN1. The pellet culture environment also promoted the expression of hypoxia-inducible cartilage markers compared with cells grown on 3D scaffolds. Conclusions: Cell type–specific effects of low oxygen and 3D environments indicate that mesenchymal cell fate and differentiation potential is remarkably sensitive to oxygen. Genetic programming of AMSCs to a chondrocytic phenotype is effective under hypoxic conditions as evidenced by increased expression of cartilage-related biomarkers and biosynthesis of a glycosaminoglycan-positive matrix. Lower local oxygen levels within cartilage pellets may be a significant driver of chondrogenic differentiation.
Which Malpositioned Pedicle Screws Should Be Revised?
Floccari, Lorena V. , Larson, A. Noelle , Crawford, Charles H. , Ledonio, Charles Gerald T., Polly, David W. , Carreon, Leah Y. , Blakemore, Laurel C. , Larson, A Noelle , Polly, David

Journal of Pediatric Orthopaedics | April 19, 2016 | Volume: 38 | Issue: 2 | Pages: 110-115

10.1097/bpo.0000000000000753 Get It

Background: Up to 10% of free-hand pedicle screws are malpositioned, and 1 in 300 patients may undergo return to surgery for revision of malpositioned screws. The indications for revision of asymptomatic malpositioned screws have not been carefully examined in the literature. We sought to evaluate the threshold among spinal deformity surgeons for revision of malpositioned screws. Methods: Twelve experienced spine surgeons reviewed x-ray and computed tomographic images of 32 malpositioned pedicle screws with variable degrees of anterior, medial, and lateral breeches. The surgeons were asked whether based on the image they would revise the screw: (1) intraoperatively before rod placement; (2) intraoperatively after rod placement; (3) in clinic with an asymptomatic patient. For each scenario, we assumed stable neuromonitoring and no neurological changes. Agreement and multirater κ was calculated. Results: There was good agreement as to which screws were malpositioned (80% agreement, κ=0.703). After the rod was placed or postoperatively (scenarios 2 and 3), surgeons less frequently recommended screw revision, and there was greater variability among the surgeons’ recommendations. For return to surgery from clinic for asymptomatic screw revision, % agreement was only 65% (κ=0.477). The majority recommended revision surgery for screws which approached the dura (10/12) or the aorta (7/12 surgeons). Half of the surgeons recommended revision surgery for an asymptomatic screw if the entire screw diameter was in the canal. Revision surgery was not recommended for asymptomatic patients with screws partially violating the canal (<½ the screw diameter), malpositioned laterally in the rib head, or with small anterior cortical violations remote from a vascular structure. Conclusions: There is significant variability of opinion among surgeons regarding which malpositioned screws can be safely observed in an asymptomatic patient. Given the frequency of malpositioned screws and morbidity of surgical return to surgery, more long-term data are needed to develop practice guidelines for determining which screws require revision surgery. Level of Evidence: Level III—retrospective comparative study.
RNA‐seq analysis of clinical‐grade osteochondral allografts reveals activation of early response genes
Yang, Lin , Lewallen, Eric A. , Camilleri, Emily T. , Bonin, Carolina A. , Jones, Dakota L. , Dudakovic, Amel , Galeano‐Garces, Catalina , Wang, Wei , Karperien, Marcel , Larson, A. Noelle , Dahm, Diane L., Levy, Bruce A. , Smith, Jay , Ryssman, Daniel B., Im, Hee‐Jeong , Wijnen, André J. van , Riester, Scott M. , Krych, Aaron J. , Camilleri, Emily , Lin, Yang , Larson, Annalise N, van Wijnen, Andre J, Stuart, Michael J. , Westendorf, Jennifer J. , van Wijnen, Andre J , Krych, Aaron J , Larson, A Noelle , Camilleri, Emily

Journal of Orthopaedic Research | February 25, 2016 | Volume: 34 | Issue: 11 | Pages: 1950-1959

10.1002/jor.23209 Get It

ABSTRACTPreservation of osteochondral allografts used for transplantation is critical to ensure favorable outcomes for patients after surgical treatment of cartilage defects. To study the biological effects of protocols currently used for cartilage storage, we investigated differences in gene expression between stored allograft cartilage and fresh cartilage from living donors using high throughput molecular screening strategies. We applied next generation RNA sequencing (RNA‐seq) and real‐time reverse transcription quantitative polymerase chain reaction (RT‐qPCR) to assess genome‐wide differences in mRNA expression between stored allograft cartilage and fresh cartilage tissue from living donors. Gene ontology analysis was used to characterize biological pathways associated with differentially expressed genes. Our studies establish reduced levels of mRNAs encoding cartilage related extracellular matrix (ECM) proteins (i.e., COL1A1, COL2A1, COL10A1, ACAN, DCN, HAPLN1, TNC, and COMP) in stored cartilage. These changes occur concomitantly with increased expression of “early response genes” that encode transcription factors mediating stress/cytoprotective responses (i.e., EGR1, EGR2, EGR3, MYC, FOS, FOSB, FOSL1, FOSL2, JUN, JUNB, and JUND). The elevated expression of “early response genes” and reduced levels of ECM‐related mRNAs in stored cartilage allografts suggests that tissue viability may be maintained by a cytoprotective program that reduces cell metabolic activity. These findings have potential implications for future studies focused on quality assessment and clinical optimization of osteochondral allografts used for cartilage transplantation. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1950–1959, 2016.
What would be the annual cost savings if fewer screws were used in adolescent idiopathic scoliosis treatment in the US?
Larson, A. Noelle , Polly, David W. , Ackerman, Stacey J. , Ledonio, Charles Gerald T., Lonner, Baron S. , Shah, Suken A. , Emans, John B. , Richards, B. Stephens , _, _, _, _, Larson, A Noelle , Polly, David

Journal of Neurosurgery: Spine | September 18, 2015 | Volume: 24 | Issue: 1 | Pages: 116-123

10.3171/2015.4.spine131119 Get It

OBJECT There is substantial heterogeneity in the number of screws used per level fused in adolescent idiopathic scoliosis (AIS) surgery. Assuming equivalent clinical outcomes, the potential cost savings of using fewer pedicle screws were estimated using a medical decision model with sensitivity analysis. METHODS Descriptive analyses explored the annual costs for 5710 AIS inpatient stays using discharge data from the 2009 Kids’ Inpatient Database (Healthcare Cost and Utilization Project, Agency for Healthcare Research and Quality), which is a national all-payer inpatient database. Patients between 10 and 17 years of age were identified using the ICD-9-CM code for idiopathic scoliosis (737.30). All inpatient stays were assumed to represent 10-level fusions with pedicle screws for AIS. High screw density was defined at 1.8 screws per level fused, and the standard screw density was defined as 1.48 screws per level fused. The surgical return for screw malposition was set at $23,762. A sensitivity analysis was performed by varying the cost per screw ($600–$1000) and the rate of surgical revisions for screw malposition (0.117%–0.483% of screws; 0.8%–4.3% of patients). The reported outcomes include estimated prevented malpositioned screws (set at 5.1%), averted revision surgeries, and annual cost savings in 2009 US dollars, assuming similar clinical outcomes (rates of complications, revision) using a standard- versus high-density pattern. RESULTS The total annual costs for 5710 AIS hospital stays was $278 million ($48,900 per patient). Substituting a high for a standard screw density yields 3.2 fewer screws implanted per patient, with 932 malpositioned screws prevented and 21 to 88 revision surgeries for implant malposition averted, and a potential annual cost savings of $11 million to $20 million (4%–7% reduction in the total cost of AIS hospitalizations). CONCLUSIONS Reducing the number of screws used in scoliosis surgery could potentially decrease national AIS hospitalization costs by up to 7%, which may improve the safety and efficiency of care. However, such a screw construct must first be proven safe and effective.
Switching to a Pediatric Dose O-Arm Protocol in Spine Surgery Significantly Reduced Patient Radiation Exposure
Su, Alvin W.Y. , Luo, T. David , McIntosh, Amy L. , Schueler, Beth A. , Winkler, Jennifer, Stans, Anthony A. , Larson, A. Noelle , Su, Alvin W, Larson, A Noelle

Journal of Pediatric Orthopaedics | August 21, 2015 | Volume: 36 | Issue: 6 | Pages: 621-626

10.1097/bpo.0000000000000504 Get It

Background: Intraoperative computed tomography and image-guided navigation improve the accuracy of screw placement. Radiation exposure to the patient remains a primary drawback. The objective of the present study was to compare the total intraoperative radiation dose and assess the resultant image quality for O-arm-assisted pedicle screw insertion, among 3 protocols: default (manufacturer recommended), institutional (reduced dose utilized in our institution), and pediatric (new protocol with lowest dose). Methods: Thirty-seven consecutive patients under the age of 18 years underwent posterior instrumentation of the spine and underwent an intraoperative O-arm scan. Techniques (kV and mAs) for default and institutional dose settings were manually adjusted based on spinal level and body weight. Pediatric dose techniques were 80 kV/80 mAs with no adjustment for level or weight. The number of scans repeated because of inadequate imaging was assessed, and the mean estimated effective dose between the 3 protocols was compared. Results: Sixty-eight scans were performed in 37 consecutive patients with mean age of 14 years and mean weight of 55 kg. For reference, the effective radiation dose of a chest x-ray is approximately 0.10 mSv. Use of the default protocol resulted in higher mean effective dose per scan of 4.65 mSv, whereas institutional protocol resulted in 2.37 mSv. The pediatric protocol reduced the mean dose to 0.65 mSv. The total effective dose per surgery was: 1.17 mSv (pediatric), 3.83 mSv (institutional), and 12.79 mSv (default) (P<0.0001 each). All scans lead to satisfactory image quality except in 1 patient >100 kg with stainless steel implants. There were no neurological or other implant-related complications. The pediatric protocol resulted in satisfactory image quality with the lowest total radiation dose, only 1/10 of that of the default protocol. Conclusions: We successfully switched to a pediatric low-dose O-arm protocol in clinical practice, reducing the dose to <1/4 of the mean annual natural background radiation. This may allow use of intraoperative computed tomography and navigation for pedicle screw placement without excessive radiation exposure to young patients. Level of Evidence: Level III—retrospective comparative study.
How Does Patient Radiation Exposure Compare With Low-dose O-arm Versus Fluoroscopy for Pedicle Screw Placement in Idiopathic Scoliosis?
Su, Alvin W.Y. , McIntosh, Amy L. , Schueler, Beth A. , Milbrandt, Todd A. , Winkler, Jennifer, Stans, Anthony A. , Larson, A. Noelle , Su, Alvin W, Larson, A Noelle

Journal of Pediatric Orthopaedics | August 4, 2015 | Volume: 37 | Issue: 3 | Pages: 171-177

10.1097/bpo.0000000000000608 Get It

Background: Intraoperative C-arm fluoroscopy and low-dose O-arm are both reasonable means to assist in screw placement for idiopathic scoliosis surgery. Both using pediatric low-dose O-arm settings and minimizing the number of radiographs during C-arm fluoroscopy guidance decrease patient radiation exposure and its deleterious biological effect that may be associated with cancer risk. We hypothesized that the radiation dose for C-arm-guided fluoroscopy is no less than low-dose O-arm scanning for placement of pedicle screws. Methods: A multicenter matched-control cohort study of 28 patients in total was conducted. Fourteen patients who underwent O-arm-guided pedicle screw insertion for spinal fusion surgery in 1 institution were matched to another 14 patients who underwent C-arm fluoroscopy guidance in the other institution in terms of the age of surgery, body weight, and number of imaged spine levels. The total effective dose was compared. A low-dose pediatric protocol was used for all O-arm scans with an effective dose of 0.65 mSv per scan. The effective dose of C-arm fluoroscopy was determined using anthropomorphic phantoms that represented the thoracic and lumbar spine in anteroposterior and lateral views, respectively. The clinical outcome and complications of all patients were documented. Results: The mean total effective dose for the O-arm group was approximately 4 times higher than that of the C-arm group (P<0.0001). The effective dose for the C-arm patients had high variability based on fluoroscopy time and did not correlate with the number of imaged spine levels or body weight. The effective dose of 1 low-dose pediatric O-arm scan approximated 85 seconds of the C-arm fluoroscopy time. All patients had satisfactory clinical outcomes without major complications that required returning to the operating room. Conclusions: Radiation exposure required for O-arm scans can be higher than that required for C-arm fluoroscopy, but it depends on fluoroscopy time. Inclusion of more medical centers and surgeons will better account for the variability of C-arm dose due to distinct patient characteristics, surgeon’s preference, and individual institution’s protocol. Level of Evidence: Level III–case-control study.
Upright Biplanar Slot Scanning in Pediatric Orthopedics: Applications, Advantages, and Artifacts
Hull, Nathan C. , Binkovitz, Larry A. , Schueler, Beth A. , Kolbe, Amy B. , Larson, A. Noelle , Larson, A Noelle

American Journal of Roentgenology | June 23, 2015 | Volume: 205 | Issue: 1 | Pages: W124-W132

10.2214/ajr.14.14022 Get It