Abstract Background Interval duration measurements (IDMs) were compared between standard 12‐lead electrocardiograms (ECGs) and 6‐lead ECGs recorded with AliveCor's KardiaMobile 6L, a hand‐held mobile device designed for use by patients at home. Methods Electrocardiograms were recorded within, on average, 15 min from 705 patients in Mayo Clinic's Windland Smith Rice Genetic Heart Rhythm Clinic. Interpretable 12‐lead and 6‐lead recordings were available for 685 out of 705 (97%) eligible patients. The most common diagnosis was congenital long QT syndrome (LQTS, 343/685 [50%]), followed by unaffected relatives and patients (146/685 [21%]), and patients with other genetic heart diseases, including hypertrophic cardiomyopathy (36 [5.2%]), arrhythmogenic cardiomyopathy (23 [3.4%]), and idiopathic ventricular fibrillation (14 [2.0%]). IDMs were performed by a central ECG laboratory using lead II with a semi‐automated technique. Results Despite differences in patient position (supine for 12‐lead ECGs and sitting for 6‐lead ECGs), mean IDMs were comparable, with mean values for the 12‐lead and 6‐lead ECGs for QTcF, heart rate, PR, and QRS differing by 2.6 ms, −5.5 beats per minute, 1.0 and 1.2 ms, respectively. Despite a modest difference in heart rate, intervals were close enough to allow a detection of clinically meaningful abnormalities. Conclusions The 6‐lead hand‐held device is potentially useful for a clinical follow‐up of remote patients, and for a safety follow‐up of patients participating in clinical trials who cannot visit the investigational site. This technology may extend the use of 12‐lead ECG recordings during the current COVID‐19 pandemic as remote patient monitoring becomes more common in virtual or hybrid‐design clinical studies.
Conversion of left atrial volume to diameter for automated estimation of sudden cardiac death risk in hypertrophic cardiomyopathy
AbstractBackgroundA subset of patients with hypertrophic cardiomyopathy (HCM) is at high risk of sudden cardiac death (SCD). Practice guidelines endorse use of a risk calculator, which requires entry of left atrial (LA) diameter. However, American Society of Echocardiography (ASE) guidelines recommend the use of LA volume index (LAVI) for routine quantification of LA size. The aims of this study were to (a) develop a model to estimate LA diameter from LAVI and (b) evaluate whether substitution of measured LA diameter by estimated LA diameter derived from LAVI reclassifies HCM‐SCD risk.MethodsThe study cohort was comprised of 500 randomly selected HCM patients who underwent transthoracic echocardiography (TTE). LA diameter and LAVI were measured offline using digital clips from TTE. Linear regression models were developed to estimate LA diameter from LAVI. A European Society of Cardiology endorsed equation estimated SCD risk, which was measured using LA diameter and estimated LA diameter derived from LAVI.ResultsThe mean LAVI was 48.5 ± 18.8 mL/m2. The derived LA diameter was 45.1 mm (SD: 5.5 mm), similar to the measured LA diameter (45.1 mm, SD: 7.1 mm). Median SCD risk at 5 years estimated by measured LA diameter was 2.22% (interquartile range (IQR): 1.39, 3.56), while median risk calculated by estimated LA diameter was 2.18% (IQR: 1.44, 3.52). 476/500 (95%) patients maintained the same risk classification regardless of whether the measured or estimated LA diameter was used.ConclusionsSubstitution of measured LA diameter by estimated LA diameter in the HCM‐SCD calculator did not reclassify risk.
An autoantibody identifies arrhythmogenic right ventricular cardiomyopathy and participates in its pathogenesis