Back to Authors

Esquer Garrigos, Zerelda

0000-0003-4561-7883

Mayo Clinic

Division of Infectious Diseases, University of Mississippi Medical Center, Jackson, Mississippi, USA.

Citations 20

Discriminative Ability and Reliability of Transesophageal Echocardiography in Characterizing Cases of Cardiac Device Lead Vegetations Versus Noninfectious Echodensities
George, Merit P., Garrigos, Zerelda Esquer , Vijayvargiya, Prakhar , Anavekar, Nandan S., Wilson, Walter R. , Sohail, M. Rizwan , Esquer Garrigos, Zerelda , Luis, Sushil A , Sohail, M Rizwan , Luis, Sushil Allen , Baddour, Larry M.

Clinical Infectious Diseases | April 22, 2020 | Volume: 72 | Issue: 11 | Pages: 1938-1943

10.1093/cid/ciaa472 Get It

Abstract Background Approximately one-third of cases of cardiovascular implantable electronic device (CIED) infection present as CIED lead infection. The precise transesophageal echocardiographic (TEE) definition and characterization of “vegetation” associated with CIED lead infection remain unclear. Methods We identified a sample of 25 consecutive cases of CIED lead infection managed at our institution between January 2010 and December 2017. Cases of CIED lead infection were classified using standardized definitions. Similarly, a sample of 25 noninfected patients who underwent TEE that showed a defined lead echodensity during the study period was included as a control group. TEEs were reviewed by 2 independent echocardiologists who were blinded to all linked patient demographic, clinical, and microbiological information. Reported echocardiographic variables of the infected vs noninfected cases were compared, and the overall diagnostic performance was analyzed. Results Descriptions of lead echodensities were variable and there were no significant differences in median echodensity diameter or mobility between infected vs noninfected groups. Among infected cases, blinded echocardiogram reports by either reviewer correctly made a prediction of infection in 6 of 25 (24%). Interechocardiologist agreement was 68%. Sensitivity of blinded TEEs ranged from 31.5% to 37.5%. Conclusions Infectious vs noninfectious lead echodensities could not be reliably distinguished on the basis of size, mobility, and general shape descriptors obtained from a retrospective blinded TEE examination without knowledge of clinical and microbiological parameters. Therefore, a reanalysis of criteria used to support a diagnosis of CIED lead infection may be warranted.
Linezolid and fentanyl: An underrecognized drug‐to‐drug interaction
Campioli, Cristina Corsini , Barth, Dylan , Garrigos, Zerelda Esquer , Saleh, Omar Abu , Sohail, Rizwan M., Sia, Irene G. , Corsini Campioli, Cristina , Esquer Garrigos, Zerelda , Abu Saleh, Omar , Sia, Irene G

Journal of Clinical Pharmacy and Therapeutics | April 18, 2020 | Volume: 45 | Issue: 4 | Pages: 825-827

10.1111/jcpt.13143 Get It

Preclinical evaluation of efficacy and pharmacokinetics of gentamicin containing extracellular‐matrix envelope
Sohail, M. Rizwan , Garrigos, Zerelda Esquer , Elayi, Claude S. , Xiang, Kun , Catanzaro, John N. , Esquer Garrigos, Zerelda , Sohail, M Rizwan

Pacing and Clinical Electrophysiology | February 18, 2020 | Volume: 43 | Issue: 3 | Pages: 341-349

10.1111/pace.13888 Get It

Abstract Background Using synthetic antibiotic‐eluting envelope (ABE) is an effective intervention for prevention of cardiovascular implantable electronic device (CIED) infection. The biologic extracellular‐matrix envelope (ECME), may offer potential advantages over the synthetic ABE. To further minimize the risk of infection, the ECME can be hydrated in gentamicin prior to CIED implantation. We aimed to evaluate the efficacy and pharmacokinetics (PK) of gentamicin containing ECME in an animal model. Methods For all experiments, the ECME was hydrated in gentamicin (40 mg/Ml) (treatment) for 2 min. In vitro antimicrobial efficacy against six different bacterial species was assessed. In vivo experiments were conducted using a rabbit model of CIED pocket infection. Serum and ECM gentamicin concentrations were measured. Five different organisms were inoculated into the device pocket of control (ECME hydrated in 0.9% saline) and treatment groups. Macroscopic appearance and colony forming units from CIED, ECME, and tissue were determined. Results No bacteria were recovered from any culture after 12 h of exposure to the gentamicin containing ECME. Serum gentamicin levels dropped below the limit of quantification at 15 h after implant. Gentamicin concentration in the ECME remained relatively stable for up to 7 days. Signs of clinical infection were observed in the control but not in the treatment group. In the presence of gentamicin, statistically significant reduction was demonstrated across all tested bacterial species. Conclusions In this preclinical animal infection model, gentamicin containing ECME was highly effective in reducing bacterial burden in the implant pocket, while systemic exposure after implantation remained low.
Spinal Cord Stimulator Infection: Approach to Diagnosis, Management, and Prevention
Garrigos, Zerelda Esquer , Farid, Saira, Bendel, Markus A. , Esquer Garrigos, Zerelda , Sohail, M. Rizwan

Clinical Infectious Diseases | October 8, 2019 | Volume: 70 | Issue: 12 | Pages: 2727-2735

10.1093/cid/ciz994 Get It

AbstractSpinal cord stimulation (SCS) is the most utilized invasive electrical neuromodulation treatment for the management of refractory chronic pain syndromes. Infection is one of the most dreaded complications related to SCS implantation and may prevent patients from receiving adequate pain treatment, adding to the initial cost and disability. Most SCS infections present as generator pocket infection. However, delay in diagnosis may lead to complications such as meningitis, epidural abscess, and/or vertebral osteomyelitis. Early recognition of SCS-related infections and associated complications is based on clinical suspicion, laboratory testing, and appropriate diagnostic imaging. While superficial surgical site infection following SCS implant may be treated with antibiotic therapy alone, deep infection involving implant warrants device removal to achieve cure. Duration of antimicrobial therapy depends on severity of clinical presentation and presence or absence of associated complications. Several preventive strategies can be incorporated in surgical practice to reduce the risk of SCS infection.
Infective endocarditis due to Granulicatella elegans presenting with musculoskeletal symptoms
Farid, Saira, Garrigos, Zerelda Esquer , Sohail, Muhammad Rizwan , Sohail, M. Rizwan , Esquer Garrigos, Zerelda , Sohail, Muhammad Rizwan , Sohail, M Rizwan

BMJ Case Reports | August 29, 2019 | Volume: 12 | Issue: 8 | Pages: e229294

10.1136/bcr-2019-229294 Get It

A 62-year-old man with essential hypertension and right L4-L5 hemilaminectomy was referred to rheumatology for evaluation of severe arthralgia and myalgia for 12 months. Review of symptoms was significant for night sweats and 20 pounds unintentional weight loss. Physical examination was significant for holosystolic murmur best heard at the cardiac apex of unclear chronicity. Laboratory investigations revealed elevated inflammatory markers, white blood cell count and B-type natriuretic peptide. Transoesophageal echocardiogram showed flail posterior mitral leaflet with severe mitral regurgitation and two vegetations (2.5×1 cm and 1.6×0.3 cm). Abdominal CT showed new focal splenic infarcts, and a brain MRI revealed subacute infarcts, consistent with the embolic phenomenon. Blood cultures grew Granulicatella elegans. The patient underwent mitral valve replacement surgery followed by 6 weeks of parenteral therapy with vancomycin and gentamicin, with full recovery at a 3-month follow-up.
Attachment is the source of all suffering: delineating mechanisms of adhesion in Staphylococcus aureus endocarditis
Garrigos, Zerelda Esquer , Sohail, M. Rizwan , Esquer Garrigos, Zerelda , Sohail, M Rizwan

European Heart Journal | May 10, 2019 | Volume: 40 | Issue: 39 | Pages: 3260-3262

10.1093/eurheartj/ehz353 Get It

Abstract
Molecular Approach to Diagnosis of Cardiovascular Implantable Electronic Device Infection
Garrigos, Zerelda Esquer , Greenwood‐Quaintance, Kerryl E. , Cunningham, Scott A. , Vijayvargiya, Prakhar , Fida, Madiha , Friedman, Paul A. , Mandrekar, Jayawant N. , Patel, Robin , Esquer Garrigos, Zerelda , Mandrekar, Jayawant, Patel, Robin , Fida, Madiha , Cunningham, Scott A , Sohail, M. Rizwan , DeSimone, Daniel C. , Baddour, Larry M.

Clinical Infectious Diseases | March 26, 2019 | Volume: 70 | Issue: 5 | Pages: 898-906

10.1093/cid/ciz266 Get It

Abstract Background Sonicate fluid (SF), a solution derived from vortexing and sonication of explanted cardiovascular implantable electronic devices (CIEDs), is a higher-yield specimen compared with swabs or tissues for culture-based detection of microorganisms associated with CIED infection. Despite this, SF culture fails to identify a causative organism in ~50% of cases. We aimed to evaluate the diagnostic performance of 16S ribosomal RNA gene (rRNA) polymerase chain reaction (PCR)/sequencing of SF and compare it with that of SF culture. Methods We identified 322 SF specimens from extracted CIEDs and reviewed clinical data for each patient. Subjects were classified as having or not having CIED infection. Cases were subcategorized as culture negative if no significant growth was reported from SF cultures and as culture positive if an organism was detected above predefined thresholds. 16S rRNA PCR/sequencing was performed, with the organisms identified reported according to Clinical and Laboratory Standards Institute guidelines for sequence data interpretation. Results A total of 278 SF samples corresponded to infected cases, of which 160 were culture positive and 118 culture negative. The remaining 44 were from noninfected cases, of which 2 were culture positive. Compared with SF culture, the sensitivity of 16S rRNA PCR/sequencing was higher (64% vs 57.5%, P = .003). 16S rRNA PCR/sequencing detected a potential pathogen in 28 of 118 culture-negative cases, identifying staphylococci in the majority (18/28). Conclusions 16S rRNA PCR/sequencing has higher sensitivity to detect bacteria in SF from extracted CIEDs than does SF culture.
Predictors of Bloodstream Infection in Patients Presenting With Cardiovascular Implantable Electronic Device Pocket Infection
Garrigos, Zerelda Esquer , George, Merit P., Khalil, Sarwat , Vijayvargiya, Prakhar , Saleh, Omar Abu , Friedman, Paul A. , Steckelberg, James M., Wilson, Walter R., Sohail, M. Rizwan , Esquer Garrigos, Zerelda , Abu Saleh, Omar M, Sohail, M Rizwan , DeSimone, Daniel C. , Baddour, Larry M.

Open Forum Infectious Diseases | February 20, 2019 | Volume: 6 | Issue: 4 | Pages: No page available

10.1093/ofid/ofz084 Get It

Nitazoxanide Is a Therapeutic Option for Adenovirus-Related Enteritis in Immunocompromised Adults
Garrigos, Zerelda Esquer , Hamdi, Ahmed , Saleh, Omar Abu , Sohail, M. Rizwan , Esquer Garrigos, Zerelda , Barth, Dylan , Hamdi, Ahmed M , Abu Saleh, Omar M, Sohail, M Rizwan , Barth, Dylan

Antimicrobial Agents and Chemotherapy | September 27, 2018 | Volume: 62 | Issue: 12 | Pages: No page available

10.1128/aac.01937-18 Get It

Diagnostic evaluation and management of culture‐negative cardiovascular implantable electronic device infections
Garrigos, Zerelda Esquer , George, Merit P., Farid, Saira, Saleh, Omar Abu , Vijayvargiya, Prakhar , Mahmood, Maryam , Friedman, Paul A. , Steckelberg, James M., DeSimone, Daniel C. , Wilson, Walter R. , Sohail, M. Rizwan , Esquer Garrigos, Zerelda , Abu Saleh, Omar M, Sohail, M Rizwan , DeSimone, Daniel C , Mahmood, Maryam , Baddour, Larry M.

Pacing and Clinical Electrophysiology | June 1, 2018 | Volume: 41 | Issue: 8 | Pages: 933-942

10.1111/pace.13397 Get It

AbstractBackgroundCulture‐negative (CN) cardiovascular implantable electronic device (CIED) infections represent a significant management challenge for clinicians with no specific guidelines addressing this subgroup of patients. The aim of the current investigation is to report our institutional experience of CN CIED infections and propose a systematic approach to diagnostic evaluation and management of these complicated cases based on our observations.MethodsWe retrospectively screened all CIED infection cases at Mayo Clinic from 2005 through 2017. Using standardized criteria to define significant microbial growth, all patients with positive blood or pocket/device cultures were excluded.ResultsA total of 835 cases of CIED infection were screened, and of these, 47 (6%) met CN‐CIED infection criteria. Majority of patients (77%) in this cohort had received antimicrobial therapy prior to device cultures with a median duration of 8 days. The most common presentation was device pocket infection (81%). All patients underwent device removal. Route of antibiotics was switched from oral to parenteral and spectrum of activity expanded from initial therapy in 23% of patients despite negative cultures. Majority of patients (80%) were dismissed on parenteral therapy. Adverse events attributed to intravenous antibiotic therapy were documented in 63% of the cases. No recurrence was reported and 6‐month survival was 94.8%.ConclusionsPocket and device cultures in suspected CIED infections may be negative due to preextraction oral antibiotics. However, frequently these patients are managed with broad‐spectrum parenteral therapy postextraction.