Clinical implementation of respiratory‐gated spot‐scanning proton therapy: An efficiency analysis of active motion management
Gelover, Edgar, Deisher, A., Herman, Michael , Johnson, J. , Kruse, Jon J. , Tryggestad, E., Deisher, Amanda J, Herman, Michael G., Johnson, Jedediah E, Tryggestad, Erik J

Journal of Applied Clinical Medical Physics | April 11, 2019 | Volume: 20 | Issue: 5 | Pages: 99-108

10.1002/acm2.12584 Get It

AbstractPurposeThe aim of this work is to describe the clinical implementation of respiratory‐gated spot‐scanning proton therapy (SSPT) for the treatment of thoracic and abdominal moving targets. The experience of our institution is summarized, from initial acceptance and commissioning tests to the development of standard clinical operating procedures for simulation, motion assessment, motion mitigation, treatment planning, and gated SSPT treatment delivery.Materials and methodsA custom respiratory gating interface incorporating the Real‐Time Position Management System (RPM, Varian Medical Systems, Inc., Palo Alto, CA, USA) was developed in‐house for our synchrotron‐based delivery system. To assess gating performance, a motion phantom and radiochromic films were used to compare gated vs nongated delivery. Site‐specific treatment planning protocols and conservative motion cutoffs were developed, allowing for free‐breathing (FB), breath‐holding (BH), or phase‐gating (Ph‐G). Room usage efficiency of BH and Ph‐G treatments was retrospectively evaluated using beam delivery data retrieved from our record and verify system and DICOM files from patient‐specific quality assurance (QA) procedures.ResultsMore than 70 patients were treated using active motion management between the launch of our motion mitigation program in October 2015 and the end date of data collection of this study in January 2018. During acceptance procedures, we found that overall system latency is clinically‐suitable for Ph‐G. Regarding room usage efficiency, the average number of energy layers delivered per minute was <10 for Ph‐G, 10‐15 for BH and ≥15 for FB, making Ph‐G the slowest treatment modality. When comparing to continuous delivery measured during pretreatment QA procedures, the median values of BH treatment time were extended from 6.6 to 9.3 min (+48%). Ph‐G treatments were extended from 7.3 to 13.0 min (+82%).ConclusionsActive motion management has been crucial to the overall success of our SSPT program. Nevertheless, our conservative approach has come with an efficiency cost that is more noticeable in Ph‐G treatments and should be considered in decision‐making.
Quantifying the setup uncertainty of a stereotactic murine micro-image guided radiation therapy system
Walb, Matthew C., Carlson, Brett L. , Tryggestad, E., Tryggestad, Erik J, Sarkaria, Jann N.

The British Journal of Radiology | October 9, 2018 | Volume: 92 | Issue: 1095 | Pages: 20180487

10.1259/bjr.20180487 Get It

Knowledge of endoscopic ultrasound-delivered fiducial composition and dimension necessary when planning proton beam radiotherapy
Gleeson, Fergus , Tryggestad, E., Remmes, Nicholas B. , Beltran, Chris , Kruse, Jon J. , Haddock, Michael G. , Hallemeier, Christopher L. , Storm, Andrew C. , Levy, Michael J. , Tryggestad, Erik J, Beltran, Chris J., Storm, Andrew C , Beltran, Chris J , Hallemeier, Christopher Leigh , Levy, Michael J.

Endoscopy International Open | June 5, 2018 | Volume: 06 | Issue: 06 | Pages: E766-E768

10.1055/a-0588-4800 Get It

Abstract Background and study aims Little consideration has been given to selection of endoscopic ultrasound-guided fiducials for proton radiotherapy and the resulting perturbations in the therapy dose and pattern. Our aim was to assess the impact of perturbations caused by six fiducials of different composition and dimensions in a phantom gel model. Materials and methods The phantom was submerged in a water bath and irradiated with a uniform 10 cm × 10 cm field of 119.7 MeV monoenergetic spot scanning protons delivered through a 45 mm range shifter. The proton “Bragg Peak” was evaluated. Results Dose perturbations manifesting as dose reductions up to 30 % were observed. A carbon composite (1 × 5 mm) and gold (0.4 × 10 mm) fiducial with backload potential rather than dedicated EUS pre-loaded gold fiducial needles had the best performance in terms of minimizing the dose perturbation. Conclusions Our data demonstrate that a carbon composite fiducial has a less untoward effect on proton therapy dose distribution than dedicated EUS pre-loaded gold fiducial needles. Such information is important to consider when selecting fiducials specifically for proton therapy.
Carbon fiducials for large choroidal melanoma treated with gamma knife radiosurgery
Reynolds, Margaret , Whitaker, Thomas J. , Parney, Ian F. , Kozelsky, Timothy F., Garces, Yolanda I. , Foote, Robert L. , Tryggestad, E., Pulido, José S. , Reynolds, Margaret M, Tryggestad, Erik J, Parney, Ian F , Reynolds, Margaret M

Acta Ophthalmologica | February 20, 2016 | Volume: 94 | Issue: 8 | Pages: No page available

10.1111/aos.12982 Get It