Department of Anesthesiology, Mayo Clinic, Rochester, Minnesota; Department of Physiology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands;
Citations 5
Convalescent Plasma Antibody Levels and the Risk of Death from Covid-19
New Findings What is the central question of this study? Is lower body negative pressure a useful surrogate to study white blood cell responses to haemorrhage in humans? What is the main finding and its importance? We found that lower body negative pressure appears to be a useful surrogate to study the early white blood cell mobilization response during blood loss. Hypovolaemia has been associated with an immune response that might be secondary to sympathoexcitation. We tested the hypothesis that simulated hypovolaemia using lower body negative pressure (LBNP) and real hypovolaemia induced via experimental blood loss (BL) cause similar increases in the white blood cell concentration ([WBC]). We measured [WBC] and catecholamine concentrations in 12 men who underwent an LBNP and a BL protocol in a randomized order. We compared 45 mmHg of LBNP with 1000 ml of BL; therefore, [WBC] and catecholamine concentrations were plotted against central venous pressure to obtain stimulus–response relationships using the linear regression line slopes for both protocols. Mean regression line slopes were similar for total [WBC] (LBNP 183 ± 4 μl−1 mmHg−1 versus BL 155 ± 109 μl−1 mmHg−1, P = 0.15), neutrophils (LBNP 110 ± 2 μl−1 mmHg−1 versus BL 96 ± 72 μl−1 mmHg−1, P = 0.15) and lymphocytes (LBNP 65 ± 21 μl−1 mmHg−1 versus BL 59 ± 38 μl−1 mmHg−1, P = 0.90). Mean regression line slopes for adrenaline were similar (LBNP 15 ± 5 pg ml−1 mmHg−1 versus BL 16 ± 4 pg ml−1 mmHg−1, P = 0.84) and were steeper during LBNP for noradrenaline (LBNP 28 ± 6 pg ml−1 mmHg−1 versus BL 9 ± 6 pg ml−1 mmHg−1, P = 0.01). These data indicate that central hypovolaemia elicits a relative leucocytosis with a predominantly neutrophil‐based response. Additionally, our results indicate that LBNP models the stimulus–response relationship between central venous pressure and [WBC] observed during BL.
Coagulation changes during lower body negative pressure and blood loss in humans
We tested the hypothesis that markers of coagulation activation are greater during lower body negative pressure (LBNP) than those obtained during blood loss (BL). We assessed coagulation using both standard clinical tests and thrombelastography (TEG) in 12 men who performed a LBNP and BL protocol in a randomized order. LBNP consisted of 5-min stages at 0, −15, −30, and −45 mmHg of suction. BL included 5 min at baseline and following three stages of 333 ml of blood removal (up to 1,000 ml total). Arterial blood draws were performed at baseline and after the last stage of each protocol. We found that LBNP to −45 mmHg is a greater central hypovolemic stimulus versus BL; therefore, the coagulation markers were plotted against central venous pressure (CVP) to obtain stimulus-response relationships using the linear regression line slopes for both protocols. Paired t-tests were used to determine whether the slopes of these regression lines fell on similar trajectories for each protocol. Mean regression line slopes for coagulation markers versus CVP fell on similar trajectories during both protocols, except for TEG α° angle (−0.42 ± 0.96 during LBNP vs. −2.41 ± 1.13°/mmHg during BL; P < 0.05). During both LBNP and BL, coagulation was accelerated as evidenced by shortened R-times (LBNP, 9.9 ± 2.4 to 6.2 ± 1.1; BL, 8.7 ± 1.3 to 6.4 ± 0.4 min; both P < 0.05). Our results indicate that LBNP models the general changes in coagulation markers observed during BL.
Reductions in central venous pressure by lower body negative pressure or blood loss elicit similar hemodynamic responses
The purpose of this study was to compare hemodynamic and blood analyte responses to reduced central venous pressure (CVP) and pulse pressure (PP) elicited during graded lower body negative pressure (LBNP) to those observed during graded blood loss (BL) in conscious humans. We hypothesized that the stimulus-response relationships of CVP and PP to hemodynamic responses during LBNP would mimic those observed during BL. We assessed CVP, PP, heart rate, mean arterial pressure (MAP), and other hemodynamic markers in 12 men during LBNP and BL. Blood samples were obtained for analysis of catecholamines, hematocrit, hemoglobin, arginine vasopressin, and blood gases. LBNP consisted of 5-min stages at 0, 15, 30, and 45 mmHg of suction. BL consisted of 5 min at baseline and following three stages of 333 ml of hemorrhage (1,000 ml total). Individual r2 values and linear regression slopes were calculated to determine whether the stimulus (CVP and PP)-hemodynamic response trajectories were similar between protocols. The CVP-MAP trajectory was the only CVP-response slope that was statistically different during LBNP compared with BL (0.93 ± 0.27 vs. 0.13 ± 0.26; P = 0.037). The PP-heart rate trajectory was the only PP-response slope that was statistically different during LBNP compared with BL (−1.85 ± 0.45 vs. −0.46 ± 0.27; P = 0.024). Norepinephrine, hematocrit, and hemoglobin were all lower at termination in the BL protocol compared with LBNP ( P < 0.05). Consistent with our hypothesis, LBNP mimics the hemodynamic stimulus-response trajectories observed during BL across a significant range of CVP in humans.